IRC Flash Cards Quizzes Complete With A+ Graded Answers Wall bracing Method PFG (Portal frame at garage door openings) is limited to walls supporting ____ ____ and a _____. one story, roof Garage floor surfaces shall be of approved ____ material Noncombustible Opening from a private garage directly into a room used for ___ ___ shall not be permitted. Sleeping purposes Doors between the garage and residential shall be equipped with a ___ - ___ ___. Self-closing or automatic-closing device In cold-formed steel framing, king, jack and cripple studs shall be of the same dimension and thickness as the adjacent ___ studs. Wall Grout shall not be pumped through ___ pipes. Aluminum Steel studs and other structural members shall not be ___. spliced Flanged and lips of load-bearing cold-formed steel floor framing members shall not be cut or ___. Notched Each dwelling unit shall be provided with a kitchen area and every kitchen area shall be provided with a ___. Sink Basements, habitable attics and every sleeping room shall have at least one operable ___ ___ and ___ ___. Emergency escape and rescue opening A finished or unfinished habitable space within an attic. Attic, Habitable Every dwelling unit shall be provided with a water closet, lavatory, and a ___ or ___. Bathtub or shower

Show more Read less
Institution
Course

Content preview

IRC Flash Cards Quizzes Complete With A+
Graded Answers
Wall bracing Method PFG (Portal frame at garage door openings) is limited to walls supporting ____
____ and a _____.
one story, roof


Garage floor surfaces shall be of approved ____ material
Noncombustible


Opening from a private garage directly into a room used for ___ ___ shall not be permitted.
Sleeping purposes


Doors between the garage and residential shall be equipped with a ___ - ___ ___.
Self-closing or automatic-closing device


In cold-formed steel framing, king, jack and cripple studs shall be of the same dimension and
thickness as the adjacent ___ studs.
Wall


Grout shall not be pumped through ___ pipes.
Aluminum


Steel studs and other structural members shall not be ___.
spliced


Flanged and lips of load-bearing cold-formed steel floor framing members shall not be cut or ___.
Notched


Each dwelling unit shall be provided with a kitchen area and every kitchen area shall be provided with
a ___.
Sink


Basements, habitable attics and every sleeping room shall have at least one operable ___ ___ and ___
___.
Emergency escape and rescue opening


A finished or unfinished habitable space within an attic.
Attic, Habitable


Every dwelling unit shall be provided with a water closet, lavatory, and a ___ or ___.
Bathtub or shower


Glazing in all fixed and operable panels of swinging, sliding and bifold doors shall be considered a ___
___.

,Hazardous location


Window wells serving emergency escape and rescue opening shall be designed for proper.
Drainage


Signifies access that requires the removal of an access panel or similar removable obstruction.
Access (to)


There shall be a floor or ___ at the top and bottom of each stairway.
Landing


Is plastic composite materials permitted for use as exterior stair treads?
Yes


A thermal barrier is not required for foam plastic insulation in an attic that is entered only for purpose
of ___ or ___.
Repairs or maintenance


Attics containing mechanical appliance shall be provided with an opening and a clear and
unobstructed passageway to allow removal of the ___ appliance.
Largest


Masonry veneer above openings shall be supported on lintels of ___ materials.
Noncombustible


Under-floor plenums shall be ___ in new structures.
Prohibited


A wall supported any vertical load in addition to its own weight is a ___ - ___ wall.
Load-bearing


Unused openings in cabinets and panel boards shall be effectively ___ to afford protection equivalent
to that of the wall of the cabinet.
Closed


Bonding shall be provide where necessary to ensure electrical.
Continuity


Electrical panel boards and overcurrent devices shall not be located in ___.
Clothes closets, bathrooms or over the steps of a stairway


Connected to establish electrical continuity and conductivity.
Bonded (Bonding)

, The ___ shall not be considered as an effective ground-fault current path.
Earth


Receptacles installed on 15- and 20-ampere-rated branch circuits shall be of the ___ type.
Grounding


Recessed incandescent fixture shall have ___ protection.
Thermal


Ceiling-suspended paddle fans shall be supported ___ of an outlet box.
Independently


All mechanical elements used to terminate a grounding electrode conductor or bonding jumper to the
grounding electrodes shall be ___.
Accessible


Underground service laterals that are not encased in concrete and that are buried 18-inches or more
below grade shall have their location identified by a ___ ___.
Warning ribbon


Branch circuit rating for space-heating and water-heating appliance shall be considered ___ loads.
Continuous


Insulated conductors and cables exposed to direct rays of the sun shall be listed and label as ___ ___.
Sunlight resistant


Where raceways are installed in wet locations above grade, the interior of such raceways shall be
considered to be a ___ location.
Wet


Web holes in steel wall studs shall not exceed ___ inches in width or ___ inches in length.
1.5 inches
4.5 inches


Protection of wood and wood-based products from ___ shall be provided in specified locations by the
use of naturally durable wood or wood that is preservative-treaded.
Decay


Unless other wise recommended by the drain manufacturer, perforated foundation drains shall be
surrounded with an approved ___ ___.
Filter membrane


A permit is not required for the replacement of branch circuit overcurrent devices (breakers) of the
required capacity in the same location (within a panel).

Written for

Course

Document information

Uploaded on
May 13, 2024
Number of pages
24
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$13.50
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
LectDan Teachme2-tutor
Follow You need to be logged in order to follow users or courses
Sold
221
Member since
3 year
Number of followers
157
Documents
7985
Last sold
3 days ago

4.0

48 reviews

5
25
4
12
3
2
2
4
1
5

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions