PLUMBING LEVEL 1 COMPREHENSIVE QUESTIONS
AND VERIFIED CORRECT ANSWERS EXAM
PREPARATION TEST 2024 UPDATE


What is the minimum size of a building sewer?
4 inches T710.1 (1) b
Minimum fall shall not be less than _____ per foot for a 2 inch pipe or _________
per foot for a 4 inch pipe.
1/4":1/8". T704.1
A pipe or a fitting which makes an angle of not more than 45° with the vertical is
considered
Vertical pipe. 202- definitions
Cleanouts in 4 inch building sewer shall not be located more than ____ft. apart
100 ft. 708.3 .2
Size of cleanouts for a 4 inch pipe or larger may be served by a _______inch
clean out
4". 708.7
Size of cleanouts for less than a 4 inch pipe ---- 4 inch, 2 inch, size of pipe or 3
inch?
Size of pipe 708.7
The pipe from the water main, water meter, water supply system or other
approved source of water supply,to the building or structure
Water service pipe
Any pipe or fitting which makes angle of more than 45° with the vertical
Horizontal pipe
The length of a pipe along the centerline of the pipe and fittings
Developed length
For applicability requirements of the plumbing code, refer to:
The plumbing code 102.1
The provisions of the plumbing shall apply to:
Installations, alterations and repairs, replacements - 101.2
The provisions of the plumbing code shall NOT apply to...
Gas fired water heater, water heater venting systems, fuel gas piping
Waste and soil pipe leaving a building shall have an earth cover ______ inches
3 inches. 305.6.1
A manhole cover in a flood hazard zone (a zone) shall be sealed unless
The manhole is elevated above base flood elevation 309.2#6
Temporary toilet facilities need not be on site for crews on a job site for no more
then which of the following?
One day 311.1

, Strainer plates on drain inlet shall be designed with openings not greater than
____
.5 " 304.2
What is the size of a sleeve passing through a wall to protect piping?
Two pipe diameters greater than the pipe 305.5
All plastic pipe, fittings and component shall be third-party certified as
conforming to which of the following?
NSF 14. 303.3
All openings around pipes, tubing, wiring, conduit, Etc. Shall be fire stopped
according to which of the following?
The building code 307.3
The top of water pipes, installed below grade outside the building, shall be:
Below the frost line or minimum of 12 inches below finished grade which ever is greater
305.6
Water piping installed in an unconditioned area shall be insulated with a
minimum R factor of:
6.50 305.6
Trenches installed parallel to footings shall not extend below the bearing the
plane of the footing:
45° 307.5
Exterior wall openings shall be made which of the following?
Watertight. 305.7
Notches at the end of joists shall not exceed:
1/4 of the depth. 307.2, F101.1
The edge of a bored hole in a stud shall be no closer to the edge than:
5/8" 307.2, F101.3
Protective shield plates shall extend at least which of the following above the sole
plate
2" 305.8
When backfilling above a pipe is complete, which of the following is the proper
depth above the crown of the pipe?
12" 306.3
When testing the water distribution system which of the following shall be used
when testing plastic piping?
Water 312.5
In toilet rooms used by five-year-olds, which of the following may be omitted ?
Toilet stall enclosures, toilet stall doors, partitions between toilets 310.4 exceptions
1 inch copper tube shall be supported vertically at intervals not exceeding:
10' T308.5
CPVC 1 inch pipe shall be supported horizontally at intervals no more than:
3' T308.5
All the piping in the plumbing system shall be tested with:
Water or air 312.1
Drainage piping when tested with water shall be subjected to which of the
following?
10 feet head of water 312.2

Geschreven voor

Vak

Documentinformatie

Geüpload op
14 mei 2024
Aantal pagina's
10
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$23.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
MEGAMINDS Chamberlain University College of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
3922
Lid sinds
4 jaar
Aantal volgers
85
Documenten
2958
Laatst verkocht
4 weken geleden
Top sellers

I specialize in crafting papers of various topics and complexities, always meeting deadlines with punctuality and precision. Whether it's research papers, case studies, or psychology papers, I'm committed to delivering engaging and informative content. With a passion for academic writing, I excel in structuring papers and presenting information creatively. Client satisfaction is my priority, and I take pride in impressing them with high-quality work. Your requirements are my focus, ensuring fresh ideas, consistent structure, and adherence to academic formatting rules. Additionally, for every referred student who completes and pays for an assignment transparently, I offer a complimentary assignment completion as a token of appreciation. Your satisfaction drives my dedication to excellence!

Lees meer Lees minder
4.4

715 beoordelingen

5
429
4
212
3
50
2
9
1
15

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen