Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

NATE ICE Heat Pump Exam Questions with 100% Correct Answers

Beoordeling
-
Verkocht
-
Pagina's
3
Cijfer
A+
Geüpload op
15-05-2024
Geschreven in
2023/2024

NATE ICE Heat Pump Exam Questions with 100% Correct Answers A correct statement regarding the outdoor coil of a heat pump is that damage may result if the: defrost water does not drain from the coil. A dirty air filter in a heat pump operating in the heating mode could result in: excessive head pressure. A dirty air filter on a heat pump system will result in: high head pressure in the heat mode and low suction pressure in the cool mode. A fan delay can add cooling efficiency by: operating the indoor blower after compressor shut-down A heat pump that uses a piston-type metering device on the indoor coil has a piston with a larger-than-recommended orifice. This will result in: low head pressure and high suction pressure in the cooling cycle. A new 3-ton heat pump installation has an undersized return air duct. In the heating mode, the unit will most likely: go off on high pressure safety. A technician has just installed a heat pump. It heats satisfactorily, but will not cool. A possible cause of this problem is the: indoor check valve is stuck open An electric furnace has four 5-kW elements that are rated at 240V. The available voltage to operate the furnace is 208V. Which of the following indicates the effect that this will have on the BTUH output of the furnace? it will reduce the BTUH output of the furnace. An electric furnace is controlled by a single-stage thermostat. On a call for heat, all connected circuits function properly; however, the heat rise across the furnace is much lower than design requirement. Which one of the following actions should the technician take to correct this problem? reduce the air volume through the furnace Coefficient of Performance (COP) is used primarily in the heating/cooling field to compare heat-pump efficiencies to those of: electric heating units. During the initial startup of a heat pump with a long line set, which of the following is the most accurate method to charge the system? put the unit into the cooling mode and charge it by the superheat method

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

NATE ICE Heat Pump Exam Questions with
100% Correct Answers
A correct statement regarding the outdoor coil of a heat pump is that damage may result if the:
defrost water does not drain from the coil.


A dirty air filter in a heat pump operating in the heating mode could result in:
excessive head pressure.


A dirty air filter on a heat pump system will result in:
high head pressure in the heat mode and low suction pressure in the cool mode.


A fan delay can add cooling efficiency by:
operating the indoor blower after compressor shut-down


A heat pump that uses a piston-type metering device on the indoor coil has a piston with a larger-
than-recommended orifice. This will result in:
low head pressure and high suction pressure in the cooling cycle.


A new 3-ton heat pump installation has an undersized return air duct. In the heating mode, the unit
will most likely:
go off on high pressure safety.


A technician has just installed a heat pump. It heats satisfactorily, but will not cool. A possible cause of
this problem is the:
indoor check valve is stuck open


An electric furnace has four 5-kW elements that are rated at 240V. The available voltage to operate
the furnace is 208V. Which of the following indicates the effect that this will have on the BTUH output
of the furnace?
it will reduce the BTUH output of the furnace.


An electric furnace is controlled by a single-stage thermostat. On a call for heat, all connected circuits
function properly; however, the heat rise across the furnace is much lower than design requirement.
Which one of the following actions should the technician take to correct this problem?
reduce the air volume through the furnace


Coefficient of Performance (COP) is used primarily in the heating/cooling field to compare heat-pump
efficiencies to those of:
electric heating units.


During the initial startup of a heat pump with a long line set, which of the following is the most
accurate method to charge the system?
put the unit into the cooling mode and charge it by the superheat method

Geschreven voor

Vak

Documentinformatie

Geüpload op
15 mei 2024
Aantal pagina's
3
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$10.59
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
EXAMSMART Howard Community College
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
10
Lid sinds
2 jaar
Aantal volgers
2
Documenten
3001
Laatst verkocht
1 maand geleden
SMART.SCORES

On this page, you find all documents, package deals, and flashcards offered by seller LectJoshua.

5.0

2 beoordelingen

5
2
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen