Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

Test Bank for Radiography Questions and Answers 2023 Guaranteed A+

Rating
-
Sold
-
Pages
143
Grade
A+
Uploaded on
17-05-2024
Written in
2023/2024

Test Bank for Radiography Questions and Answers 2023 Guaranteed A+++++

Institution
Course

Content preview

Radiography Testbank Questions and Answers
2023 Guaranteed A+++++

Which of the following modes of a trifield image intensifier will result in the highest patient dose?
A. Its 25-in. mode
B. Its 17-in. mode
C. Its 12-in. mode
D. Diameter does not affect patient dose

Its 12-in. mode

A particular AP thoracic measurement is 25 cm. What tomographic sections are indicated if we desire
one midline and one each anterior and posterior to midline?
A. 8, 9, and 10 cm
B. 10, 11, and 12 cm
C. 12, 13, and 14 cm
D. 14, 15, and 16 cm

12, 13, and 14 cm

T/F: The cooling oil in an x-ray tube is part of the inherent filtration

TRUE

When using the smaller field in a dual-field image intensifier,
1. a smaller patient area is viewed.
2. the image is magnified.
3. the image is less bright.

AOTA

Design characteristics of x-ray tube targets that determine heat capacity include the
1 rotation of the anode
2 diameter of the anode
3 size of the focal spot

AOTA

A technique chart should be prepared for each AEC x-ray unit and should contain which of the following
information for each type of examination?
1 Photocell(s) used
2 Optimum kilovoltage
3 Backup time

AOTA

,Which of the following statements regarding dual x-ray absorptiometry is (are) true?
1 It is a low-dose procedure.
2 Two x-ray photon energies are used.
3 Photon attenuation by bone is calculated.

AOTA

Disadvantages of moving grids over stationary grids include which of the following?
1 They can prohibit the use of very short exposure times.
2 They increase patient radiation dose.
3 They can cause phantom images when anatomic parts parallel their motion.

1 and 2 ONLY

How is the thickness of the tomographic section related to the tomographic angle?
A. The greater the tomographic angle, the thicker the section.
B. The greater the tomographic angle, the thinner the section.
C. The less the tomographic angle, the thinner the section.
D. The tomographic angle is unrelated to section thickness.

The greater the tomographic angle, the thinner the section.

All the following x-ray circuit devices are located between the incoming power supply and the primary
coil of the high-voltage transformer except
A. the timer
B. the kilovoltage meter
C. the milliamperage meter
D. the autotransformer

the milliamperage meter

Which of the following techniques is used to evaluate the dynamics of a part?
A. Fluoroscopy
B. Stereoscopy
C. Tomography
D. Phototiming

Fluoroscopy

In which of the following examinations would a cassette front with very low absorption properties be
especially important?
A. Abdominal radiography
B. Extremity radiography
C. Angiography
D. Mammography

Mammography

The ability of an x-ray unit to produce constant radiation output, at a given mA, using various
combinations of mAs and time is called

,A. linearity.
B. reproducibility.
C. densitometry.
D. sensitometry.

linearity

Advantages of battery-powered mobile x-ray units include their
1 ability to store a large quantity of energy
2 ability to store energy for extended periods of time
3 lightness and ease of maneuverability

1 and 2 ONLY

Star and wye configurations are related to
A. autotransformers
B. three-phase transformers
C. rectification systems
D. AECs

three-phase transformers

When the radiographer selects kilovoltage on the control panel, which device is adjusted?
A. Step-up transformer
B. Autotransformer
C. Filament circuit
D. Rectifier circuit

Autotransformer

The total brightness gain of an image intensifier is the product of
1 flux gain
2 minification gain
3 focusing gain

1 and 2 ONLY

Which of the following is used in digital fluoroscopy, replacing the image intensifier's television camera
tube?
A. Solid-state diode
B. Charge-coupled device
C. Photostimulable phosphor
D. Vidicon

Charge-coupled device

Which of the following devices is used to control voltage by varying resistance?
A. Autotransformer
B. High-voltage transformer

, C. Rheostat
D. Fuse

Rheostat

Which of the following equipment is mandatory for performance of a myelogram?
A. Cine camera
B. 105-mm spot film
C. Tilting x-ray table
D. Tomography

Tilting x-ray table

Which of the following devices is (are) component(s) of a typical fluoroscopic video display system?
1 Videotape recorder
2 TV camera
3 TV monitor

2 and 3

The x-ray tube in a CT imaging system is most likely to be associated with
A. low-energy photons
B. an unrestricted x-ray beam
C. a pulsed x-ray beam
D. a large focal spot

a pulsed x-ray beam

Accurate operation of the AEC device depends on
1 the thickness and density of the object
2 positioning of the object with respect to the photocell
3 beam restriction

2 and 3 ONLY

Which of the following would be appropriate cassette front material(s)?
1 Tungsten
2 Magnesium
3 Bakelite

2 and 3 ONLY

The image intensifier's input phosphor generally is composed of
A. cesium iodide
B. zinc cadmium sulfide
C. gadolinium oxysulfide
D. calcium tungstate

cesium iodide

Connected book

Written for

Course

Document information

Uploaded on
May 17, 2024
Number of pages
143
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$12.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Stuviashop Teachme2-tutor
Follow You need to be logged in order to follow users or courses
Sold
18
Member since
2 year
Number of followers
7
Documents
506
Last sold
1 week ago
StudyStack

Welcome to StudyStack, your ultimate destination for high-quality study materials tailored to meet your academic needs! At StudyStack, we curate a diverse collection of meticulously crafted notes, summaries, guides, and practice exams meticulously prepared by experienced scholars and educators. Whether you're striving for top grades, preparing for exams, or seeking comprehensive resources to deepen your understanding, our repository offers a wealth of resources across various subjects and disciplines. With a commitment to excellence and academic success, StudyStack is your trusted partner on your educational journey. Browse our extensive catalog today and unlock the keys to mastering your studies with confidence!

Read more Read less
3.7

3 reviews

5
1
4
0
3
2
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions