Journeymen Gas Fitter EXam Questions With Correct Answers an appliance has a demand of 180,000 btu/h. It is communicating with the outdoors through horizontal openings. what is the minimum net free area of each opening. 2,000 btu per square inch. 90 sq inch is the answer . 304.6.1 what is the minimum required distance that a connector to a mason chimney flue should be above the lowest portion of the interior chimney flue 12 inches. 501.9 minimum distance from combustible construction for medium heat equipment to single wall metal pipe 36 inches. 503.10.5 gas piping shall not penetrate builidng foundation walls at any point below grade. 404.6 Recirculating direct-fired industial air heaters are required to provide properly designed _______ relief openings. 612.7 what code regulates storage of liquefied petroleum gas NFPA 58. 401.2 The radius of the inner curve of plastic piping bends shall not be less than ________ the inside diameter of the pipe 25 times. 405.3 unvented room heaters should be equipped with an ________ depletion sensitive safety shutoff system oxygen. 621.6 A single category 1 appliance has a gas demand of 98,000 btu/h. What is the max horizontal run for the double wall Type B vent if it has a vertical run of 30 feet? 30 feet. table 502.2(1) A vent connector is passing through an unconditioned space. what shall the portion of the vent connector be listed as? B or L. 503.10.2.2 No portion of a venting system shall pass through any circulation air duct or________. Furnace Plenum. 503.3.5 what is the minimum burial depth underground gas piping 12 inches. 404.12

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

Journeymen Gas Fitter EXam Questions With
Correct Answers
an appliance has a demand of 180,000 btu/h. It is communicating with the outdoors through
horizontal openings. what is the minimum net free area of each opening.
2,000 btu per square inch. 90 sq inch is the answer . 304.6.1


what is the minimum required distance that a connector to a mason chimney flue should be above
the lowest portion of the interior chimney flue
12 inches. 501.9


minimum distance from combustible construction for medium heat equipment to single wall metal
pipe
36 inches. 503.10.5


gas piping shall not penetrate builidng foundation walls
at any point below grade. 404.6


Recirculating direct-fired industial air heaters are required to provide properly designed _______
relief openings. 612.7


what code regulates storage of liquefied petroleum gas
NFPA 58. 401.2


The radius of the inner curve of plastic piping bends shall not be less than ________ the inside
diameter of the pipe
25 times. 405.3


unvented room heaters should be equipped with an ________ depletion sensitive safety shutoff
system
oxygen. 621.6


A single category 1 appliance has a gas demand of 98,000 btu/h. What is the max horizontal run for
the double wall Type B vent if it has a vertical run of 30 feet?
30 feet. table 502.2(1)


A vent connector is passing through an unconditioned space. what shall the portion of the vent
connector be listed as?
B or L. 503.10.2.2


No portion of a venting system shall pass through any circulation air duct or________.
Furnace Plenum. 503.3.5


what is the minimum burial depth underground gas piping
12 inches. 404.12

, what is the minimum distance that a tee fitting shall be installed downstream of a medium pressure
regulator outlet
10 pipe diameters. 410.2


what is the minimum thickness for an 8 inch galvanized steel vent connector for a low-heat appliance.
0.023 inches. table 503.10.2.4


which of the following is not true regarding cast iron fittings for gas piping
bushings are permitted. 403.10.4


what is they minimum height of a cleanout on a masonry chimney flue
6 inches. 501.15.3


When gas piping is in solid floors and one end terminates outdoors, how far shall the casing extend
beyond the point where the pipe emerges from the floor?
2 inches. 404.8.1


an appliance has a demand of 80,000 btu/h. It is communicating directly with the outdoors. what is
the minimum net free area of each opening.
20 sq inch. 304.6.1


what is the approximate length of the threaded portion on 1 inch iron gas pipe.
7/8 inches. table 403.92


what is the minimum clearance at the back for a floor mounted type unit heater to combustible
materials.
6 inches. 620.4


For other than black steel pipe, exposed piping shall be identified by a yellow marked "gas" in black
letters. what is the maximum spacing of the marking.
5 feet. 401.5


Approximately how many threads are to be cut on 4 inch iron gas pipe
13. table 403.9.2


which of the following matallic pipes is not permitted to be used for gas piping
cast-iron. 403.4.1


for gas piping underground beneath buildings, how far shall the conduit for gas piping extend outside
of a building when one end terminates outdoors.
4 inches. 404.14.1


which of the following is true regarding thread compounds.
shall be resistant to the action of lp gas. 403.9.3

Geschreven voor

Vak

Documentinformatie

Geüpload op
17 mei 2024
Aantal pagina's
5
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$10.59
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
LectDeniz Teachme2-tutor
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
21
Lid sinds
2 jaar
Aantal volgers
13
Documenten
4974
Laatst verkocht
7 maanden geleden
Lect Deniz Academic Resources Hub

Lect Deniz is a highly experienced academic tutor and dedicated content creator with a strong track record of developing comprehensive, high-quality study materials for a wide range of university courses across the globe. With years of experience in higher education support, he excels at transforming complex academic concepts into clear, structured, and easy-to-follow resources that enhance student understanding and confidence. He provides an extensive collection of well-researched and carefully organized documents across key disciplines, including nursing, medicine, and various science fields. His materials cover essential topics such as anatomy, physiology, pharmacology, clinical practice, and core scientific principles, making them highly valuable for both coursework and intensive exam preparation. Each document is thoughtfully designed to align with university standards and curricula, ensuring accuracy, relevance, and practical application. Lect Aziim’s work stands out for its clarity, depth, and attention to detail, offering students concise summaries, detailed explanations, and exam-focused content that supports effective revision. His commitment to academic excellence and student success is reflected in the consistency and reliability of his materials, making him a trusted resource for learners seeking to improve performance and achieve their academic goals.

Lees meer Lees minder
5.0

1 beoordelingen

5
1
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen