NATE Heat Pump Exam Questions and Answers 100% Correct Charging a heat pump with refrigerant is best accomplished in the _______ mode. A: Heating mode B: Cooling mode C: Defrost mode D: Emergency heating mode - CORRECT ANSWER-B: Cooling mode Heat pumps can provide both heating in the winter and cooling in the summer. In which mode is the heat pump more efficient? A: Heating mode B: Cooling mode C: Defrost mode D: Emergency heating mode - CORRECT ANSWER-A: Heating mode Which of the following components is exclusive to the heat pump? A: Condenser B: Oil separator C: Reversing valve D: Accumulator - CORRECT ANSWER-C: Reversing valve Which of the following airflow rates is the most reasonable for a heat pump system operating in the heating cycle? A: 200 cfm per ton B: 300 cfm per ton C: 400 cfm per ton D: 450 cfm per ton - CORRECT ANSWER-D: 450 cfm per ton During the heat pump's cooling cycle, the outdoor coil is utilized as a _________ while the indoor coil is utilized as a____________. A: Condenser, evaporator B: Evaporator, condenser C: Compressor, accumulator D: Accumulator, condenser - CORRECT ANSWER-A: Condenser, evaporator Heat is present in winter outdoor air until the outside air ambient temperature reaches a low temperature of: A: 0 degrees F B: 32 degrees F C: 273 degrees F D: -459 degrees F - CORRECT ANSWER-D: -459 degrees F Technically this is true, but not practical. A heat pump is doing good to continue to work below 10 deg F unless specifically designed for lower temperatures.
Voorbeeld van de inhoud
driers with check valves The correct way to size a heat pump is to perform both heating and cooling load calculations and select the heat pump size by: A: Adding the heating load and cooling loads B: Subtracting the smaller load from the larger load
Geschreven voor
- Instelling
- Nate heat pump service
- Vak
- Nate heat pump service
Documentinformatie
- Geüpload op
- 20 mei 2024
- Aantal pagina's
- 13
- Geschreven in
- 2023/2024
- Type
- Tentamen (uitwerkingen)
- Bevat
- Vragen en antwoorden
Onderwerpen
-
nate heat pump exam questions and answers 100 co
-
charging a heat pump with refrigerant is best acco
-
heat is present in winter outdoor air until the ou
-
why are reversing valves pilot operated
Ook beschikbaar in voordeelbundel