100% CORRECT ANSWERS { GRADED
A+}
ASME - ✔✔American Society of Mechanical Engineers
DOSH - ✔✔Division of Occupational Safety and Health
LADBS - ✔✔Los Angeles Department of Building and Safety
Alteration made to conveyance shall comply with ASME A17.1-204
Section - ✔✔8.7
The seismic section of ASME A17.1-2004 and alterations made to
conveyances must also comply with this section - ✔✔8.4
What must be submitted to the applicable Division Elevator office prior
to beginning construction or alterations on a conveyance
,Title 8 Sec 3000 - ✔✔Letter of Intent
When shall Category One Tests on conveyances be completed
Title 8 Sec 3141.6 - ✔✔Once every 12 months
What shall be provided on all conveyances regardless of the existence of
an emergency stop switch
ASME A17.1-2004
2.27.1.2 - ✔✔Audible signaling device
When are Hoistway door unlocking devices on all conveyances required
Title 8 Sec 3141.7
ASME A17.1-2004
2.12.6 - ✔✔Prohibited
What section should Group IV platform lifts and stairway chairlifts shall
comply with - ✔✔ASME A18.1-2003
,When setbacks or projections exceed this number of inches, occur in the
enclosure wall, the top of the setback or projection shall be beveled at an
angle not less than 75 degrees with the horizontal
ASME A17.1-2004
2.1.6 - ✔✔4 inches
At what height shall the hoistway enclosure of a Group IV elevator be
Unperforated
ASME A17.1-2004
2.1.1.2.2 - ✔✔79 inches
For elevators installed after June 5, 1947, there shall be installed in the
pit of each elevator where the pit extends below the sill of the pit access
door a fixed vertical ladder. How many inches below the sill?
ASME A17.1-2004
2.2.4.2 - ✔✔35 inches
, On a Group IV elevator, what is the minimum pit lighting illumination
that should be provided at the pit floor
ASME A17.1-2004
2.2.5.1 - ✔✔10 fc (foot candles)
For Group IV elevators that are not fully enclosed, how high of
protection should be provided on the hoistway sides that are located 59
inches or less from elevator equipment in areas accessible to other than
elevator personnel
ASME A17.1-2004
2.2.1.3 - ✔✔94.5 inches
Permanent means shall be provided to prevent the accumulation of
what?, in the elevator pit
ASME A17.1-2004
2.2.2.3 - ✔✔Water