HVAC JOURNEYMAN PREP TEST EXAM QUESTIONS AND ANSWERS WITH COMPLETE SOLUTIONS VERIFIED LATEST UPDATE A listed smoke damper designed to resist the passage of smoke shall be provided at each point in a duct or air transfer opening penetrates a: (A)smoke barrier wall (B)fire rated wall (C)interior wall (D)corridor wall Corridor wall (IMC 607.5.4) Flexible air duct may be what length? (A)10' (B)2' (C)14' (D)6' 14' (IMC 603.6.1.1) The maximum vertical distance between the front lower lip of a canopy Type 1 hood and the appliance surface shall be ____ feet: (A)5' (B)3' (C)6' (D)4' 4' (IMC 507.4.1) The return air duct to a blower type warm air furnace is being replaced, how many sq. inches of free air are required per 1,000 BTU or rated capacity of the furnace? (A)3" (B)1" (C)4" (D)2" 2" (Fuel Gas Code 9.3.3.2) The existing terminals of a mechanical draft system shall not be less than ___ feet above finished ground level where located adjacent to public walkways: (A)7' (B)2' (C)8' (D)5' 7' (IMC 804.3.4 #1) What device is installed to prevent a back draft occurring in an appliance? (A)Power draft vent (B)Vent cap (C)Saftey relief valve (D)Draft hood Draft hood (Fuel Gas Code, 3.3.33) Minimum distance between the lowest edge of a grease filter and the cooking surface with exposed flame or burners is: (A)42" (B)6" (C)48" (D)24" 24" (IMC Table 507.2.8) Non-metallic ducts shall have a flame spread index of ___ or less and a smoke-devolped index of ___ or less: (A)100,200 (B)84,723 (C)50,100 (D)25,50 25,50 (IMC 602.2.1) A blower fan used for the purpose of distributing supply air to a room, space, or area is a: (A)Air-handling unit (B)Return fan (C)Make-up fan (D)Exhaust fan Air handling unit (IMC Chapter #2) Maximum flame spread distance of ___ feet for combustable electrical wires, cables, and optical fiber cables exposed within a plenum: (A)30' (B)3' (C)70' (D)5' 5' (IMC 602.2.1.1) Where all combustion air is provided by a mechanical air supply system, the combustion air shall be supplied from outdoors at the minimum rate of: (A)100ft3/1000BTU/hr (B)0.35ft3/1000BTU/hr (C) 25ft3/1000BTU/hr (D)50ft/1000BTU/hr 0.35ft3/1000BTU/hr (Fuel Gas Code, 9.3.6) A chimney for a residential type or low-heat appliances shall exceed at least ___ feet above the highest point where it passes through the roof of a building? (A)5' (B)2' (C)10' (D)3' 3' (Fuel Gas Code, 12.6.2.1) A chimney for a low heat appliance must withstand a continuous flue gas temperature not exceeding ___: (A)1000 (B)1800 (C)800 (D)1200 1000 (IMC 202 Appliance Type) When running flue gas pipe, any angle greater than ___ from the vertical is considered to be horizontal: (A)30 (B)60 (C)45 (D)90 45 (Fuel Gas Code, 12.7.3.2) A direct vent appliance with an input over 50,000BTU/hr, shall have at least ___ inches from any air opening into a building: (A)12 (B)6 (C)18 (D)9 12 (Fuel code 12.9.3) Unless otherwise specified by the designer, that sealing requirements do not contain provisions to: withstanding temperatures higher than ___ degrees F, or lower than ___ degrees F: (A)120, 40 (B)175, -30 (C)40,120 (D)212, 32 120, 40 (SMACNA S1.9 e. 4. )

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

HVAC JOURNEYMAN PREP TEST EXAM QUESTIONS AND
ANSWERS WITH COMPLETE SOLUTIONS VERIFIED LATEST
UPDATE


A listed smoke damper designed to resist the passage of smoke shall be
provided at each point in a duct or air transfer opening penetrates a: (A)smoke
barrier wall (B)fire rated wall (C)interior wall (D)corridor wall
Corridor wall (IMC 607.5.4)
Flexible air duct may be what length? (A)10' (B)2' (C)14' (D)6'
14' (IMC 603.6.1.1)
The maximum vertical distance between the front lower lip of a canopy Type 1
hood and the appliance surface shall be ____ feet: (A)5' (B)3' (C)6' (D)4'
4' (IMC 507.4.1)
The return air duct to a blower type warm air furnace is being replaced, how many
sq. inches of free air are required per 1,000 BTU or rated capacity of the furnace?
(A)3" (B)1" (C)4" (D)2"
2" (Fuel Gas Code 9.3.3.2)
The existing terminals of a mechanical draft system shall not be less than ___
feet above finished ground level where located adjacent to public walkways: (A)7'
(B)2' (C)8' (D)5'
7' (IMC 804.3.4 #1)
What device is installed to prevent a back draft occurring in an appliance?
(A)Power draft vent (B)Vent cap (C)Saftey relief valve (D)Draft hood
Draft hood (Fuel Gas Code, 3.3.33)
Minimum distance between the lowest edge of a grease filter and the cooking
surface with exposed flame or burners is: (A)42" (B)6" (C)48" (D)24"
24" (IMC Table 507.2.8)

,Non-metallic ducts shall have a flame spread index of ___ or less and a smoke-
devolped index of ___ or less: (A)100,200 (B)84,723 (C)50,100 (D)25,50
25,50 (IMC 602.2.1)
A blower fan used for the purpose of distributing supply air to a room, space, or
area is a: (A)Air-handling unit (B)Return fan (C)Make-up fan (D)Exhaust fan
Air handling unit (IMC Chapter #2)
Maximum flame spread distance of ___ feet for combustable electrical wires,
cables, and optical fiber cables exposed within a plenum: (A)30' (B)3' (C)70' (D)5'
5' (IMC 602.2.1.1)
Where all combustion air is provided by a mechanical air supply system, the
combustion air shall be supplied from outdoors at the minimum rate of:
(A)100ft3/1000BTU/hr (B)0.35ft3/1000BTU/hr (C) 25ft3/1000BTU/hr
(D)50ft/1000BTU/hr
0.35ft3/1000BTU/hr (Fuel Gas Code, 9.3.6)
A chimney for a residential type or low-heat appliances shall exceed at least ___
feet above the highest point where it passes through the roof of a building? (A)5'
(B)2' (C)10' (D)3'
3' (Fuel Gas Code, 12.6.2.1)
A chimney for a low heat appliance must withstand a continuous flue gas
temperature not exceeding ___: (A)1000 (B)1800 (C)800 (D)1200
1000 (IMC 202 Appliance Type)
When running flue gas pipe, any angle greater than ___ from the vertical is
considered to be horizontal: (A)30 (B)60 (C)45 (D)90
45 (Fuel Gas Code, 12.7.3.2)
A direct vent appliance with an input over 50,000BTU/hr, shall have at least ___
inches from any air opening into a building: (A)12 (B)6 (C)18 (D)9
12 (Fuel code 12.9.3)
Unless otherwise specified by the designer, that sealing requirements do not
contain provisions to: withstanding temperatures higher than ___ degrees F, or
lower than ___ degrees F: (A)120, 40 (B)175, -30 (C)40,120 (D)212, 32
120, 40 (SMACNA S1.9 e. 4. )

, What minimum pitch per foot is required for the horizontal run of a vent
connector? (A)3/4" (B)1/4" (C)1" (D)1/2"
1/4" (Fuel code 12.11.7)
Maximum allowable load size for 1"x18Ga. hanger is: (A)420lbs (B)260lbs
(C)700lbs (D)320LBS
420lbs (SMACNA Table 5-1)
At least ___ feet of clearance shall be available between the access opening and
the edge of the roof: (A)8' (B)4' (C)10' (D)6'
6' (Fuel code 9.4.3.3)
A type 1 hood shall have what minimum clearance to combustable materials?
(A)14" (B)6" (C)18" (D)10"
18" (IMC 507.2.6)
Unless complying as underground duct per section 603.8, ducts shall be installed
a minimum of ___ inches from the earth: (A)4" (B)2" (C)6" (D)3'
4" (IMC 603.14)
Smoke detectors shall be located downstream of an air filter and ahead of any
branch connectors in a return stream with flow greater than: (A)4,000CFM
(B)2,000CFM (C)5,000CFM (D)3,000CFM
2,000CFM (IMC 606.2.1)
What material is used only on a fan that comes in contact with flammable or
explosive vapor? (A)Ferris steel with painted body (B)Cast steel (C)Non-ferris
steel coating with non-sparking metal (D)Forged steel
Non-ferris steel coated with non-sparking material (?)
Joints, seams, and penetrations of grease ducts shall be made with a continuous
liquid-tight ___ made on the external surface of the duct system: (A)Foil taped
connection (B)Soldered connection (C)Weld or braze (D)Lapped and sealed
Weld or braze (IMC 506.3.2)
A duct system for hazardous exhaust shall be required whenever a flammable
vapor is present in concentrating ___ percent of its lower flammability limit:
(A)15% (B)20% (C)30% (D)25%
25% (IMC 510.2 #1)

Geschreven voor

Vak

Documentinformatie

Geüpload op
29 mei 2024
Aantal pagina's
17
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$8.69
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
TopGradeSolutions Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
95
Lid sinds
2 jaar
Aantal volgers
9
Documenten
13297
Laatst verkocht
4 dagen geleden
TOPGRADESOLUTIONS

Here we offer revised study materials to elevate your educational outcomes. We have verified learning materials (Research, Exams Questions and answers, Assignments, notes etc) for different courses guaranteed to boost your academic results. We are dedicated to offering you the best services and you are encouraged to inquire further assistance from our end if need be. Having a wide knowledge in Nursing, trust us to take care of your Academic materials and your remaining duty will just be to Excel. Remember to give us a review, it is key for us to understand our clients satisfaction. We highly appreciate clients who always come back for more of the study content we offer, you are extremely valued. All the best.

Lees meer Lees minder
4.9

171 beoordelingen

5
159
4
7
3
4
2
0
1
1

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen