Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

CCI RVS Actual Exam Questions 100% Correct Answers Verified 2024 Version

Rating
-
Sold
-
Pages
8
Grade
A+
Uploaded on
16-06-2024
Written in
2023/2024

CCI RVS Actual Exam Questions | 100% Correct Answers | Verified 2024 Version What is the major difference between protocols for cardiac treadmill and claudication treadmill testing? - Speed is varied during a cardiac treadmill test to increase heartrate to a specific target level. During a treadmill test, patient complains of pain in the left arm and jaw, but denies any other pain. What is the most likely consideration? - Angina. What is the normal diameter for the abdominal aorta? - 2-3 cm. After walking 5 minutes on treadmill, patient experiences decrease in ankle pressure of 40% on right and 15% on left. These findings suggest? - Claudication. What is the correct setting for arterial volume recording? - AC-coupled output. What Doppler waveform abnormality in the lower extremity arterial circulation distal to a hemodynamically significant stenosis show? - An absent flow recersal component, blunting of the peak velocity and prolonged upslope and downslope. A normal arterial volume waveform may have all EXCEPT: Swift upstroke, sharp peak, rapid downslope bowed toward baseline, dicrotic notch or reverse flow component? - Reverse flow component because it is part of a Doppler waveform not volume waveform. T or F- Most analog Doppler analysis is qualitative, assessing for presence or absence of characteristics. - True. What is the normal response of ankle pressure to exercise testing? - There should be no change if normal.With severe lower extremity arterial occlusive disease, how will distal Doppler waveforms appear? - Markedly dampened, possibly making interpretation difficult for distal segments. What is the usual cuff pressure used in arterial volume recording? - 65 mmHg. What would the CFA signal look like with aortoiliac occlusion? - Low pitched and monophasic. T or F- Diastolic flow reversal is always present in all abnormal limbs. - False. It may be absent in vasodialted limbs. What is the most important reason Doppler evaluations should be performed with patient in a basal state and warm temperature? - The results are influenced by the patient's peripheral resistence. Audible Doppler venous signals are usually low frequency and vary with respiration, where as normal arterial signals in the arms and legs are __________________. - Relatively high frequency with pulsatile components and dont change with respiration. When listening with CW Doppler over a stenotic lesion you will hear high frequency or low frequency sound? - High frequency.

Show more Read less
Institution
Course

Content preview

CCI RVS Actual Exam Questions | 100%
Correct Answers | Verified 2024 Version
What is the major difference between protocols for cardiac treadmill and claudication treadmill testing?
- ✔✔Speed is varied during a cardiac treadmill test to increase heartrate to a specific target level.



During a treadmill test, patient complains of pain in the left arm and jaw, but denies any other pain.
What is the most likely consideration? - ✔✔Angina.



What is the normal diameter for the abdominal aorta? - ✔✔2-3 cm.



After walking 5 minutes on treadmill, patient experiences decrease in ankle pressure of 40% on right and
15% on left. These findings suggest? - ✔✔Claudication.



What is the correct setting for arterial volume recording? - ✔✔AC-coupled output.



What Doppler waveform abnormality in the lower extremity arterial circulation distal to a
hemodynamically significant stenosis show? - ✔✔An absent flow recersal component, blunting of the
peak velocity and prolonged upslope and downslope.



A normal arterial volume waveform may have all EXCEPT: Swift upstroke, sharp peak, rapid downslope
bowed toward baseline, dicrotic notch or reverse flow component? - ✔✔Reverse flow component
because it is part of a Doppler waveform not volume waveform.



T or F- Most analog Doppler analysis is qualitative, assessing for presence or absence of characteristics. -
✔✔True.



What is the normal response of ankle pressure to exercise testing? - ✔✔There should be no change if
normal.

, With severe lower extremity arterial occlusive disease, how will distal Doppler waveforms appear? -
✔✔Markedly dampened, possibly making interpretation difficult for distal segments.



What is the usual cuff pressure used in arterial volume recording? - ✔✔65 mmHg.



What would the CFA signal look like with aortoiliac occlusion? - ✔✔Low pitched and monophasic.



T or F- Diastolic flow reversal is always present in all abnormal limbs. - ✔✔False. It may be absent in
vasodialted limbs.



What is the most important reason Doppler evaluations should be performed with patient in a basal
state and warm temperature? - ✔✔The results are influenced by the patient's peripheral resistence.



Audible Doppler venous signals are usually low frequency and vary with respiration, where as normal
arterial signals in the arms and legs are __________________. - ✔✔Relatively high frequency with
pulsatile components and dont change with respiration.



When listening with CW Doppler over a stenotic lesion you will hear high frequency or low frequency
sound? - ✔✔High frequency.



A normal PORH (postocclusive reactive hyperemia) response is a major velocity increase of what percent
increase in mean velocity? - ✔✔>100%.



What are falsely elevated less frequently than tibial ankle pressures? - ✔✔Toe pressures.



How can a PTFE graft be identified during ultrasonographic imaging? - ✔✔A double line appearance of
the graft walls.



Velocities measured in a reversed saphenous vein bypass graft are usually ___________ proximally and
____________ distally. - ✔✔Higher, lower.

Written for

Course

Document information

Uploaded on
June 16, 2024
Number of pages
8
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$8.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller
Seller avatar
hov
1.0
(2)

Also available in package deal

Get to know the seller

Seller avatar
hov State University Of West Georgia
Follow You need to be logged in order to follow users or courses
Sold
12
Member since
2 year
Number of followers
3
Documents
2125
Last sold
2 months ago
Academic Avengers

Expert Verified Exams {Latest Versions} 99% Pass Rate

1.0

2 reviews

5
0
4
0
3
0
2
0
1
2

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions