2023/2024

RETA CARO EXAM QUESTIONS WITH 100% VERIFIED ANSWERS Which refrigerant has the highest mass flow requirement at the same evaporator and condensing temperature? CFC-12 which refrigerant is the first to be phased out by Montreal Protocol CFC-12 As the ratio between the evaporator and condensing pressure increases the theoretical discharge temperature increases Under the Montreal Protocol as long as a technician does not perform work on the refrigerant containing portions of a system they do not need to be certified Refrigerant leaks are detected using Either a sulfur stick on ammonia or electronic leak detector for CFCs or HCFCs the primary reason for concern about CFC-12 concentration in an engine room is oxygen deprivation the published lower explosive limit for ammonia is 16% under normal conditions an ammonia vessel should only be filled to what percentage 80% which refrigerant can be detected by its odor even in low concentrations R-717 Which refrigerant would have the lowest condensing pressure at 95 Degrees F CFC-11 A cartridge type gas mask may legally be used for personal protection when the type of the hazard is known and the concentration is known a vapor can NOT be subcooled what kind of measure is a to of refrigeration a rate of heat transfer in BTUs per Unit of time

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

RETA CARO EXAM QUESTIONS WITH 100%
VERIFIED ANSWERS
Which refrigerant has the highest mass flow requirement at the same evaporator and condensing
temperature?
CFC-12


which refrigerant is the first to be phased out by Montreal Protocol
CFC-12


As the ratio between the evaporator and condensing pressure increases
the theoretical discharge temperature increases


Under the Montreal Protocol
as long as a technician does not perform work on the refrigerant containing portions of a system they
do not need to be certified


Refrigerant leaks are detected using
Either a sulfur stick on ammonia or electronic leak detector for CFCs or HCFCs


the primary reason for concern about CFC-12 concentration in an engine room is
oxygen deprivation


the published lower explosive limit for ammonia is
16%


under normal conditions an ammonia vessel should only be filled to what percentage
80%


which refrigerant can be detected by its odor even in low concentrations
R-717


Which refrigerant would have the lowest condensing pressure at 95 Degrees F
CFC-11


A cartridge type gas mask may legally be used for personal protection when
the type of the hazard is known and the concentration is known


a vapor can NOT be
subcooled


what kind of measure is a to of refrigeration
a rate of heat transfer in BTUs per Unit of time

Geschreven voor

Vak

Documentinformatie

Geüpload op
22 juni 2024
Aantal pagina's
2
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$11.19
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
LectDan Teachme2-tutor
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
221
Lid sinds
3 jaar
Aantal volgers
157
Documenten
7993
Laatst verkocht
1 week geleden

4.0

48 beoordelingen

5
25
4
12
3
2
2
4
1
5

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen