Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

ABO Practice Exam 2024 Questions & Answers |100% Correct

Rating
-
Sold
-
Pages
25
Grade
A+
Uploaded on
27-06-2024
Written in
2023/2024

If the wearer complains of the bifocal line being somewhat in his way when driving, the problem may be alleviated by decreasing the distance between pads. True or False - False If the wearer complains that the glasses feel snug but still slip down the nose, one likely cause is that: A. The frame is too small B. The bridge fit is tight C. Pressure is being applied by the temple shafts anterior to the ear. D. Pressure is being applied on the very tips of the temples. - Pressure is being applied by the temple shafts anterior to the ear If both nosepads press the nose or indent too much, what is probably not a possible cause? A. Pads too small for frame weight B. Temple spread is not even C. Pads too close together D. Temple tension too great - Temple spread is not even To eliminate a gap between the lens and a metal eyewire, the best alternative is to: A. Place a strip of lens liner at a point exactly opposite the gap B. Place a strip of lens liner in the gap area C. Heat the lens in the frame and allow it to cool at room temperature D. None of the above methods are satisfactoryE. All of the above methods are satisfactory - Place a strip of lens liner at a point exactly opposite the gap The larger the frame difference --------- the lens shape A. Rounder B. More squared off C. Narrower D. Wider - Narrower (Frame Difference=A-B) Which is the most favorable alternative to a 50/20 frame for measuring bifocal height when that particular size is not available? A. 52/18 B. 50/18 C. 48/20 D. 50/22 - 48/20 (would want bridge to stay the same) When the frame front is tested for four point tough, but only touches on the two temporal sides, the frame -------- A. is skewed B. has face form C. is out of coplanar alignment D. has X ing E. none of the above - Has face formWhich of the following errors will not be detected by a four point touch test? A. X-ing B. Excess face form C. Skewing D. All of the above can be detected using a four point touch - Skewing It is unnecessary to use heat in adjusting a zyl frame when: A. Bending the endpieces B. Changing the bridge area C. Bending the temple earpiece D. Changing the pantoscopic angle - Changing the pantoscopic angle If you didn't adjust the eye piece on the lensometer and the power drum reads +0.25 when the target lines are clear and focused. What do you expect the true readings for this pair of glasses be? O.D. -1.75 OS +1.75 A. -1.50, +2.00 B. -1.75, +1.75 C. -1.75, +2.00 D. -1.50, +1.75 - -1.50, +2.00 What is the final step in fitting a frame to a patient? A. Aligning the frame vertically B. Aligning the frame horizontally C. Adjusting the pantoscopic tilt

Show more Read less
Institution
Course

Content preview

ABO Practice Exam 2024 Questions & Answers |
100% Correct | Verified
If the wearer complains of the bifocal line being somewhat in his way when driving, the problem may be
alleviated by decreasing the distance between pads.



True or False - ✔✔False



If the wearer complains that the glasses feel snug but still slip down the nose, one likely cause is that:



A. The frame is too small

B. The bridge fit is tight

C. Pressure is being applied by the temple shafts anterior to the ear.

D. Pressure is being applied on the very tips of the temples. - ✔✔Pressure is being applied by the temple
shafts anterior to the ear



If both nosepads press the nose or indent too much, what is probably not a possible cause?



A. Pads too small for frame weight

B. Temple spread is not even

C. Pads too close together

D. Temple tension too great - ✔✔Temple spread is not even



To eliminate a gap between the lens and a metal eyewire, the best alternative is to:



A. Place a strip of lens liner at a point exactly opposite the gap

B. Place a strip of lens liner in the gap area

C. Heat the lens in the frame and allow it to cool at room temperature

D. None of the above methods are satisfactory

,E. All of the above methods are satisfactory - ✔✔Place a strip of lens liner at a point exactly opposite the
gap



The larger the frame difference --------- the lens shape



A. Rounder

B. More squared off

C. Narrower

D. Wider - ✔✔Narrower



(Frame Difference=A-B)



Which is the most favorable alternative to a 50/20 frame for measuring bifocal height when that
particular size is not available?



A. 52/18

B. 50/18

C. 48/20

D. 50/22 - ✔✔48/20



(would want bridge to stay the same)



When the frame front is tested for four point tough, but only touches on the two temporal sides, the
frame --------



A. is skewed

B. has face form

C. is out of coplanar alignment

D. has X ing

E. none of the above - ✔✔Has face form

, Which of the following errors will not be detected by a four point touch test?



A. X-ing

B. Excess face form

C. Skewing

D. All of the above can be detected using a four point touch - ✔✔Skewing



It is unnecessary to use heat in adjusting a zyl frame when:



A. Bending the endpieces

B. Changing the bridge area

C. Bending the temple earpiece

D. Changing the pantoscopic angle - ✔✔Changing the pantoscopic angle



If you didn't adjust the eye piece on the lensometer and the power drum reads +0.25 when the target
lines are clear and focused. What do you expect the true readings for this pair of glasses be? O.D. -1.75
OS +1.75



A. -1.50, +2.00

B. -1.75, +1.75

C. -1.75, +2.00

D. -1.50, +1.75 - ✔✔-1.50, +2.00



What is the final step in fitting a frame to a patient?



A. Aligning the frame vertically

B. Aligning the frame horizontally

C. Adjusting the pantoscopic tilt

Written for

Course

Document information

Uploaded on
June 27, 2024
Number of pages
25
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$9.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller
Seller avatar
hussle

Get to know the seller

Seller avatar
hussle Harvard College
Follow You need to be logged in order to follow users or courses
Sold
1
Member since
1 year
Number of followers
1
Documents
1635
Last sold
1 year ago
A+ ExamPrep Essentials

Explore my collection of high quality study guides and exam prep materials. Whether you\\\'re striving for top grades or looking to understand complex topics better, I provide: .Detailed Study Guide .Exam-ready notes .practice Tests .Subject coverage

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions