LMRT A+ Exam Prep Q&As 2024

2 and 3 only - ANS-Which of the following statements are correct regarding the link
between radiation dose and genetic effects

1. The link has a been demonstrated in human studies
2. The link has been demonstrated in animal studies
3. Increased risk to humans cannot be predicted with respect to an individual

Increase kVp by 30% - ANS-Which of the following changes in kilovoltage (kVp) will
result in the greatest reduction of patient dose, when milliamperage-seconds (mAs) is
adjusted to compensate for the change?

a. decrease kVp by 30%
b. decrease kVp by 15%
c. increase kVp by 15%
d. increase kVp by 30%

Faster speed IR system - ANS-Which of the following image receptor (IR) system
speeds will result in the lowest patient dose?

a. slower speed IR system
b. faster speed IR system
c. it does not matter; the IR system speed does not effect the patient dose.

Reduce the likelihood of genetic effects - ANS-What is the primary purpose of using
gonad shielding during radiography?

a. reduce the likelihood of genetic effects
b. reduce the likelihood of somatic effects
c. protect patient modesty
d. demonstrate the location of gonads in the image

2 and 3 only - ANS-Which of the following are types of gonad shields?
1. Aperture
2. Contact
3. Shadow

,When the gonads are within 5 cm of the radiation field - ANS-When should gonad
shields be used?

a. for all patients
b. for all procedures
c. when gonads are within 10 cm of the radiation field
d. when the gonads are within 5 cm of the radiation field

repeat exposures - ANS-The greatest cause of unnecessary radiation to patients that
can be controlled by the limited operator is:

a. patient condition
b. patient size
c. repeat exposures
d. equipment malfunction

clearly instructing patients - ANS-The limited operator can reduce repeat exposures by :

a. accepting marginal images
b. clearly instructing patients
c. increasing the source-image receptor distance (SID)
d. optimizing the kVP

it limits the radiation field to the area of interest - ANS-How does x-ray beam restriction
minimize patient exposure?

a. it limits radiation fog
b. it limits the radiation field to the area of interest
c. it limits the effects of patient
d. it limits repeat exposures

Collimator - ANS-What is the device that allows the limited operator to vary size of the
radiation field?

a. collimator
b. detent
c. filter
d. shield
Removes longer-wavelength photons - ANS-How does filtration reduce patient

, exposure?

a. removes shorter wavelength photons
b. removes longer wavelength photons
c. reduces size of the radiation field
d. reduces the time of exposure

2.5 mm Al equiv - ANS-What is the National Council on Radiation Protection and
Measurements (NCRP) recommendations for the amount of total filtration?

a. 0.5 mm aluminum equivalents
b. 1.5 mm Al equiv
c. 2.5 mm Al equiv
d. 3.5 mm Al equiv

time, distance, shielding - ANS-What are the three principle methods used to protect
limited operators from unnecessary radiation exposure

a. time, distance, and shielding
b. time, distance and collimation
c. distance, collimation, and shielding
d. time, collimation, and filtration

Shadow - ANS-Which of the following is not a type of personnel radiation shielding?

a. apron
b. glove
c. thyroid shield
d. shadow

Scatter radiation from the patient - ANS-Personnel shielding must be worn on the rare
occasion during which the limited operator may need to remain in the radiographic room
during an exposure to assist patient in maintaining proper position. What is the source of
the greatest radiation hazard under this circumstance?

a. off focus radiation
b. leakage radiation
c. scatter radiation from the patient
d. backscatter radiation from the IR

Geschreven voor

Vak

Documentinformatie

Geüpload op
30 juni 2024
Aantal pagina's
16
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$8.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
scholartutor Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
2771
Lid sinds
1 jaar
Aantal volgers
3
Documenten
10727
Laatst verkocht
3 dagen geleden

4.8

923 beoordelingen

5
813
4
79
3
20
2
7
1
4

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen