BACKFLOW TESTER EXAM ACTUAL QUESTIONS WITH COMPLETE SOLUTIONS VERIFIED 2024/2025 GRADED A+ A double check valve assembly is installed 12 above the floor for? Maintenance A low hazard Backflow preventer is a? Double Check valve assembly A field test report for a double check will include the manufacturer name, model, size and ?? Serial number Double check valve assembly components are?? Independently acting A double check valve assembly hydraulic use is?? Continuous A detector assembly contains a device of equal? Protection Each check valve of a double check valve assembly is forced to load to what psi? 1.0 A double check valve assembly is required to contain test cocks that total? 4 A double check valve assembly is designed to detect low flow rates up to what gpm 1 A double check detector assembly is referenced as a? DCDA A double check valve assembly installed in a vertical flow down orientation is only allowed? If approved for that orientation The max height the water will rise in a barometric loop is dependent of? Atmospheric pressure The number 1 check spring on a RP has a minimum spring tension requirement of? 5 psi Relief valves are designed to open to atmosphere when supply pressure becomes less than? 2 psi A RP has an inlet supply pressure of 97psi. The pressure in the zone will be at least? 92 psi The purpose of an RP is to? Prevent contamination from entering the water supply The application of an RP is? Any hazard application The max level of protection provided by a RP is? Health hazard A RP zone pressure should be 5 psi - less than supply A RP fouled check valve number 1 may be indicated by Continuous dripping With both shut off valves closed and test cocks 3-4 open, a continuous discharge from test cock 4 might indicate a leak through Shut off valve number 2 Lock out tag out must be used All the above An RP relief valve is loaded to Push the valve away from its seat The purpose of RP check valve number 1 loading is Create a reduction in water pressure Intermittent relief valve discharge from a RP is probably caused by Water hammer Back pressure to a RP fouled check valve number 2 likely Forced the relief valve to open and discharge An air gap separation must be maintained at a RP,s Relief valve discharge An RP's "Buffer" can be described as Difference between the check valve 1 loading and the relief valve opening point When an RP is installed vertically, the relief valve discharge must be Lower than check valve number 1

Show more Read less
Institution
Course

Content preview

BACKFLOW TESTER EXAM ACTUAL QUESTIONS WITH

COMPLETE SOLUTIONS VERIFIED 2024/2025 GRADED A+


A double check valve assembly is installed 12 above the floor for?

Maintenance

A low hazard Backflow preventer is a?

Double Check valve assembly

A field test report for a double check will include the manufacturer name, model,

size and ??

Serial number

Double check valve assembly components are??

Independently acting

A double check valve assembly hydraulic use is??

Continuous

A detector assembly contains a device of equal?

Protection

Each check valve of a double check valve assembly is forced to load to what psi?

1.0

A double check valve assembly is required to contain test cocks that total?

4

A double check valve assembly is designed to detect low flow rates up to what

gpm

,1

A double check detector assembly is referenced as a?

DCDA

A double check valve assembly installed in a vertical flow down orientation is

only allowed?

If approved for that orientation

The max height the water will rise in a barometric loop is dependent of?

Atmospheric pressure

The number 1 check spring on a RP has a minimum spring tension requirement

of?

5 psi

Relief valves are designed to open to atmosphere when supply pressure

becomes less than?

2 psi

A RP has an inlet supply pressure of 97psi. The pressure in the zone will be at

least?

92 psi

The purpose of an RP is to?

Prevent contamination from entering the water supply

The application of an RP is?

Any hazard application

The max level of protection provided by a RP is?

Health hazard

, A RP zone pressure should be

5 psi - less than supply

A RP fouled check valve number 1 may be indicated by

Continuous dripping

With both shut off valves closed and test cocks 3-4 open, a continuous discharge

from test cock 4 might indicate a leak through

Shut off valve number 2

Lock out tag out must be used

All the above

An RP relief valve is loaded to

Push the valve away from its seat

The purpose of RP check valve number 1 loading is

Create a reduction in water pressure

Intermittent relief valve discharge from a RP is probably caused by

Water hammer

Back pressure to a RP fouled check valve number 2 likely

Forced the relief valve to open and discharge

An air gap separation must be maintained at a RP,s

Relief valve discharge

An RP's "Buffer" can be described as

Difference between the check valve 1 loading and the relief valve opening point

When an RP is installed vertically, the relief valve discharge must be

Lower than check valve number 1

Written for

Course

Document information

Uploaded on
June 30, 2024
Number of pages
24
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$10.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF


Also available in package deal

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
AcademicSuperScores Chamberlain College Of Nursing
Follow You need to be logged in order to follow users or courses
Sold
299
Member since
3 year
Number of followers
37
Documents
7648
Last sold
1 week ago
AcademicSuperScores

NURSING, ECONOMICS, MATHEMATICS, BIOLOGY AND HISTORY MATERIALS. BEST TUTORING, HOMEWORK HELP, EXAMS, TESTS AND STUDY GUIDE MATERIALS WITH GUARANTEE OF A+ I am a dedicated medical practitioner with diverse knowledge in matters Nursing and Mathematics. I also have an additional knowledge in Mathematics based courses (finance and economics)

4.6

156 reviews

5
125
4
9
3
11
2
5
1
6

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions