BACKFLOW PREVENTION FINAL EXAM QUESTIONS WITH COMPLETE SOLUTIONS VERIFIED GRADED A+ 1. Backflow is defined as: a) the pressure in the distribution piping of the potable water supply b) the undesirable reversal of water, other liquids, gases or substances in the distribution pipes of the potable water supply c) high pressure in the pipes of the water user d) excess pressure through a pressure regulator b) the undesirable reversal of water, other liquids, gases or substances in the distribution pipes of the potable water supply 2. Primary responsibility for cross connection control is vested in a) the water purveyor b) the water site supervisor c) the health department d) the State Health department a) the water purveyor 3. A reduced pressure principle backflow prevention assembly is comprised of: a) two independently operating air inlet valves with a hydraulically operating mechanically independent differential relief valve b) two check valves, two shut off valves and an air relief valve c) two independently acting approved check valves, a hydraulically operated differential pressure relief valve, with four appropriately located resilient seated test cocks and two resilient seated shut off valves d) two independently operated approved check valves, mechanically operated air relief valve, four resilient seated test cocks between two resilient seated shut off valves c) two independently acting approved check valves, a hydraulically operated differential pressure relief valve, with four appropriately located resilient seated test cocks and two resilient seated shut off valves 4. A local ordinance establishing a cross connection control program must require that: a) the property owner test the assembly periodically b) a certified tester test the assembly at least once every twelve months and report the test results to the water purveyor it a timely manner c) the water purveyor will install the necessary cross connection control assembly d) pressure vacuum breaker will be installed at all service connections b) a certified tester test the assembly at least once every twelve months and report the test results to the water purveyor it a timely manner 5. The definition of an approved air gap used for backflow prevention shall be: a) be equipped with a splash guard and a receiving funnel b) be not less than one inch from the side wall of the receiving vessel c) be a vertical dimension of at least twice the diameter of the supply pipe but not less than one inch above the receiving vessel d) be less that one inch above the flood rim of the receiving vessel c) be a vertical dimension of at least twice the diameter of the supply pipe but not less than one inch above the receiving vessel 6. The correct installation of a reduced pressure principle backflow prevention assembly is: a) it doesn't matter where the assembly is placed b) in a pit behind the water meter c) in a vented vault below the floodplain d) in an above grade, protected and accessible site d) in an above grade, protected and accessible site 7. If water is continuously flowing from the relief valve port of a reduced pressure principle backflow prevention assembly the tester may report: a) the relief valve is stuck closed b) the first check may be fouled, or the differential pressure relief valve may have malfunctioned, or the second check is fouled with backpressure on the assembly c) the distribution line is subject to pressure surges d) the number two check valve has failed b) the first check may be fouled, or the differential pressure relief valve may have malfunctioned, or the second check is fouled with backpressure on the assembly 8. Backpressure will cause backflow: a) through an unprotected over the rim feed to an open make-up water tank b) through an unprotected over the rim gravity feed line to an open wash tank

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

BACKFLOW PREVENTION FINAL EXAM QUESTIONS WITH

COMPLETE SOLUTIONS VERIFIED GRADED A+


1. Backflow is defined as:

a) the pressure in the distribution piping of the potable water supply

b) the undesirable reversal of water, other liquids, gases or substances in the

distribution pipes of the potable water supply

c) high pressure in the pipes of the water user

d) excess pressure through a pressure regulator

b) the undesirable reversal of water, other liquids, gases or substances in the

distribution pipes of the potable water supply

2. Primary responsibility for cross connection control is vested in

a) the water purveyor

b) the water site supervisor

c) the health department

d) the State Health department

a) the water purveyor

3. A reduced pressure principle backflow prevention assembly is comprised of:

a) two independently operating air inlet valves with a hydraulically operating

mechanically independent differential relief valve

b) two check valves, two shut off valves and an air relief valve

c) two independently acting approved check valves, a hydraulically operated

,differential pressure relief valve, with four appropriately located resilient seated

test cocks and two resilient seated shut off valves

d) two independently operated approved check valves, mechanically operated air

relief valve, four resilient seated test cocks between two resilient seated shut off

valves

c) two independently acting approved check valves, a hydraulically operated differential

pressure relief valve, with four appropriately located resilient seated test cocks and two

resilient seated shut off valves

4. A local ordinance establishing a cross connection control program must

require that:

a) the property owner test the assembly periodically

b) a certified tester test the assembly at least once every twelve months and

report the test results to the water purveyor it a timely manner

c) the water purveyor will install the necessary cross connection control

assembly

d) pressure vacuum breaker will be installed at all service connections

b) a certified tester test the assembly at least once every twelve months and report the

test results to the water purveyor it a timely manner

5. The definition of an approved air gap used for backflow prevention shall be:

a) be equipped with a splash guard and a receiving funnel

b) be not less than one inch from the side wall of the receiving vessel

c) be a vertical dimension of at least twice the diameter of the supply pipe but not

,less than one inch above the receiving vessel

d) be less that one inch above the flood rim of the receiving vessel

c) be a vertical dimension of at least twice the diameter of the supply pipe but not less

than one inch above the receiving vessel

6. The correct installation of a reduced pressure principle backflow prevention

assembly is:

a) it doesn't matter where the assembly is placed

b) in a pit behind the water meter

c) in a vented vault below the floodplain

d) in an above grade, protected and accessible site

d) in an above grade, protected and accessible site

7. If water is continuously flowing from the relief valve port of a reduced pressure

principle backflow prevention assembly the tester may report:

a) the relief valve is stuck closed

b) the first check may be fouled, or the differential pressure relief valve may have

malfunctioned, or the second check is fouled with backpressure on the assembly

c) the distribution line is subject to pressure surges

d) the number two check valve has failed

b) the first check may be fouled, or the differential pressure relief valve may have

malfunctioned, or the second check is fouled with backpressure on the assembly

8. Backpressure will cause backflow:

a) through an unprotected over the rim feed to an open make-up water tank

b) through an unprotected over the rim gravity feed line to an open wash tank

, c) through an unprotected feed to a closed make-up water tank

d) through an unprotected feed to a cattle watering trough

c) through an unprotected feed to a closed make-up water tank

9. In testing a reduced pressure principle backflow prevention assembly:

a) the relief valve must be tested first

b) the apparent drop across the first check valve must be tested first

c) the second check must be tested first

d) the flow rate must be tested first

a) the relief valve must be tested first

10. A water purveyor or public health agency may require more frequent testing

of a backflow prevention assembly than the maximum time allowed between

testing. What is the maximum legal length of time permitted between tests:

a) six months

b) eighteen months

c) twelve weeks

d) twelve months

d) twelve months

11. Which of the following types of cross connections are considered to be

illegal?

a) a by-pass hose with a shut off valve installed around a reduced pressure

principle backflow prevention assembly

b) a supply line to a boiler from a domestic service equipped with a reduced

pressure principle backflow prevention assembly

Geschreven voor

Vak

Documentinformatie

Geüpload op
30 juni 2024
Aantal pagina's
43
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$10.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
AcademicSuperScores Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
296
Lid sinds
3 jaar
Aantal volgers
37
Documenten
7648
Laatst verkocht
16 uur geleden
AcademicSuperScores

NURSING, ECONOMICS, MATHEMATICS, BIOLOGY AND HISTORY MATERIALS. BEST TUTORING, HOMEWORK HELP, EXAMS, TESTS AND STUDY GUIDE MATERIALS WITH GUARANTEE OF A+ I am a dedicated medical practitioner with diverse knowledge in matters Nursing and Mathematics. I also have an additional knowledge in Mathematics based courses (finance and economics)

4.5

155 beoordelingen

5
124
4
9
3
11
2
5
1
6

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen