Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

DAANCE Module IV & V - Emergency Protocol /Sedation 2024 Questions & Answers 100% Correct Verified

Beoordeling
-
Verkocht
-
Pagina's
21
Cijfer
A+
Geüpload op
02-07-2024
Geschreven in
2023/2024

Flow meters- what are these used to monitor? - determines the ratio of the O2/N2O mixture as well as the rate at which it is delivered. Anesthesia Machines What are the two types of anesthesia? Where are each type of anesthesia used? What are the two machines used with the first type of anesthesia? What are two safety features of the second type of anesthesia? - -Inhalation and N2O2/O2 Anesthesia - Inhalation at the hospital, N2O2/O2 in office - vaporizers and ventilators - Regulator-fail safe Mechanism and Scavenging System Vaporizer What does this device do? What kind of maintenance does this device have? - A device that converts liquid anesthetic to gases suitable for delivery with other gases. Maintenance and Checks: periodic maintenance and frequent calibrated Ventilator What does this device do? Why is this device so useful? What type of anesthesia is this used with? What kind of maintenance does this device have? - -A machine that breathes for the pt using a bellows type apparatus with +/- pressure to move gases in and out of the lungs. -Eliminates the need to manually squeeze the reservoir bag. -Used with a closed system (i.e. Endotracheal Intubation)-The anesthetic system should have a high/low pressure alarm to indicate excessive pressure or a disconnect has occurred. Regulator-Fail Safe Mechanism What setting are these used? What level of O2 will these mechanisms be engaged at? What kind of maintenance does this mechanism require (5 things)? - -Office based anesthesia. -Most anesthesia machines will stop delivering automatically when the O2 level is unsafe (20%). Maintenance and Checks: -Flow meters, reservoir bags and delivery tubes checked daily or patentcy and leaks. -Calibrate to manufacturer specs -A record should be kept during surgery. -Turn off O2 daily -Have back up O2 available (Sep. O2 tanks) Scavenging System What does this system do? Why do we use this system? - -It reduces the level of noxious agents to an acceptable level by exhausting them outside the room. -Excess gases and vapors may be expelled in the operatory from leaks in the System or through pressure relief/pop off valves. Anesthetic Gases (color coded cylinders) Why do we color code gas tanks? Match the color to the gas (green, blue, gray, yellow, black, brown) Which gases are associated with 2000psi and 750psi? What maintenance is required for tanks? - - to minimize potential for incorrect connection to anesthesia systems. Oxygen- Green (2000psi) Nitrous Oxide- Blue (750 psi)Carbon Dioxide- Gray Compressed Air- Yellow Nitrogen- Black Helium- Brown -shut off after last pt. Airway Adjuncts -What is the first thing used in the case of airway obstruction? -What is the second step is obstruction continues? How is this placed? -What is the first type of airway placed if the initial 2 steps do not work? How is it placed, and is the patient awake or asleep? - What is the second type of airway placed? How is this placed and what is the benefit of this? Are patients awake or asleep? - 1. Bag/Valve/Mask/Full Facemask 2. Tongue Traction Suture- 1 or 2 sutures can be placed through the dorsum of the tongue and grasped with a lg. hemostat. 3.Nasopharyngeal Airway- lubricated tube passed through the nares into the nasal cavity through the oropharynx to posterior of the tongue. Easily inserted and tolerated in awake patients. 4. Oropharyngeal Airway- not tolerated well by pts. It may be placed to position the tongue more anterior. Supraglottic Airways (2 types) What are the two types? describe - 1. Laryngeal Mask Airway (LMA)- a device that consists of a plastic tube at the end of which is a small air inflated balloon that sits over the top of the larynx. 2. "I-Gel"- the balloon is filled w/gel rather than air does not req. inflation

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

DAANCE Module IV & V - Emergency Protocol / Sedation
2024 Questions & Answers | 100% Correct | Verified

Flow meters- what are these used to monitor? - ✔✔determines the ratio of the O2/N2O mixture as well
as the rate at which it is delivered.



Anesthesia Machines

What are the two types of anesthesia?

Where are each type of anesthesia used?

What are the two machines used with the first type of anesthesia?

What are two safety features of the second type of anesthesia? - ✔✔

-Inhalation and N2O2/O2 Anesthesia

- Inhalation at the hospital, N2O2/O2 in office

- vaporizers and ventilators

- Regulator-fail safe Mechanism and Scavenging System



Vaporizer

What does this device do?

What kind of maintenance does this device have? - ✔✔A device that converts liquid anesthetic to gases
suitable for delivery with other gases.

Maintenance and Checks: periodic maintenance and frequent calibrated



Ventilator

What does this device do?

Why is this device so useful?

What type of anesthesia is this used with?

What kind of maintenance does this device have? - ✔✔-A machine that breathes for the pt using a
bellows type apparatus with +/- pressure to move gases in and out of the lungs.

-Eliminates the need to manually squeeze the reservoir bag.

-Used with a closed system (i.e. Endotracheal Intubation)

,-The anesthetic system should have a high/low pressure alarm to indicate excessive pressure or a
disconnect has occurred.



Regulator-Fail Safe Mechanism

What setting are these used?

What level of O2 will these mechanisms be engaged at?

What kind of maintenance does this mechanism require (5 things)? - ✔✔-Office based anesthesia.

-Most anesthesia machines will stop delivering automatically when the O2 level is unsafe (20%).

Maintenance and Checks:

-Flow meters, reservoir bags and delivery tubes checked daily or patentcy and leaks.

-Calibrate to manufacturer specs

-A record should be kept during surgery.

-Turn off O2 daily

-Have back up O2 available (Sep. O2 tanks)



Scavenging System

What does this system do?

Why do we use this system? - ✔✔-It reduces the level of noxious agents to an acceptable level by
exhausting them outside the room.

-Excess gases and vapors may be expelled in the operatory from leaks in the System or through pressure
relief/pop off valves.



Anesthetic Gases (color coded cylinders)

Why do we color code gas tanks?

Match the color to the gas (green, blue, gray, yellow, black, brown)

Which gases are associated with 2000psi and 750psi?

What maintenance is required for tanks? - ✔✔- to minimize potential for incorrect connection to
anesthesia systems.

Oxygen- Green (2000psi)

Nitrous Oxide- Blue (750 psi)

, Carbon Dioxide- Gray

Compressed Air- Yellow

Nitrogen- Black

Helium- Brown

-shut off after last pt.



Airway Adjuncts

-What is the first thing used in the case of airway obstruction?

-What is the second step is obstruction continues? How is this placed?

-What is the first type of airway placed if the initial 2 steps do not work? How is it placed, and is the
patient awake or asleep?

- What is the second type of airway placed? How is this placed and what is the benefit of this? Are
patients awake or asleep? - ✔✔1. Bag/Valve/Mask/Full Facemask



2. Tongue Traction Suture- 1 or 2 sutures can be placed through the dorsum of the tongue and grasped
with a lg. hemostat.



3.Nasopharyngeal Airway- lubricated tube passed through the nares into the nasal cavity through the
oropharynx to posterior of the tongue. Easily inserted and tolerated in awake patients.



4. Oropharyngeal Airway- not tolerated well by pts. It may be placed to position the tongue more
anterior.



Supraglottic Airways (2 types)

What are the two types? describe - ✔✔1. Laryngeal Mask Airway (LMA)- a device that consists of a
plastic tube at the end of which is a small air inflated balloon that sits over the top of the larynx.



2. "I-Gel"- the balloon is filled w/gel rather than air

does not req. inflation

.

Geschreven voor

Vak

Documentinformatie

Geüpload op
2 juli 2024
Aantal pagina's
21
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$8.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
hussle

Maak kennis met de verkoper

Seller avatar
hussle Harvard College
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
1
Lid sinds
1 jaar
Aantal volgers
1
Documenten
1635
Laatst verkocht
1 jaar geleden
A+ ExamPrep Essentials

Explore my collection of high quality study guides and exam prep materials. Whether you\\\'re striving for top grades or looking to understand complex topics better, I provide: .Detailed Study Guide .Exam-ready notes .practice Tests .Subject coverage

0.0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen