OSP 001 PRACTICE TEST | 100% Correct Answers | Verified | Latest 2024 Version in areas where future excavation is anticipated, it may be advisable to place the cable at a greater depth. For example, if road grading that will remove 610 mm (24 in) of dirt is planned in a particular area, it would be wiser to initially place the cable at 1.2 m (4 ft) versus the standard 610 mm (24 in). - True placing all of the conduits during the initial conduit system installation is desirable, if not mandatory. *True *False - True It is not always necessary to build new pathways for cable placement *True *False - True The length of a cable loop from the switch to a customer depends on three factors - • Resistance of the cable in ohms • Signaling limits of the telephone and the terminating device switch in ohms • Pair loading Outside Plant (OSP) - Telecommunications OSP cabling began with the placement of the first telegraph system, Cable Types - • Optical fiber: - 62.5/125 micrometer (μm) multimode optical fiber (OM1). - 50/125 μm multimode optical fiber (OM2, OM3, and OM4). - Singlemode optical fiber (OS1 and OS2).• 100-ohm balanced twisted-pair. • 75-ohm coaxial. Codes - rules specified by governmental entities Installation manuals are examples of - Methodology Support structures: - - MHs). - (HHs). - Poles, support strands, and guying information. The basic types of OSP pathways and spaces are: - • Underground. • Direct-buried. • Aerial. advantage to use optical fiber in backbones campus applications: - • Increased distance. • Higher bandwidth applications. • All-dielectric cable. • Less susceptibility to EMI and lightning. • No crosstalk. • No grounding (earthing) requirement for all-dielectric cable. Optical Fiber Connectors: - • LC • SC • ST How to calculate passive cable system attenuation - Total optical fiber loss + Total connector loss+ Total splice loss Calculate link loss budget - System gain - Power penalties Splice loss values - MM SM SP type Avr. max. Avr. max. Fusion 0.05 0.3 0.05 0.3 Mecha 0.10 0.3 0.10 0.3 Ribbon fiber - designs can be single tube or multitube ,the fiber is bound in a flat array Tight-buffered fibers - have a 900 μm coating applied directly to the optical fiber. A transition point shall be required for unlisted OSP cable when the termination point is greater than _________ from the point of entrance and the cable cannot be installed in a properly rated conduit. - 15 m (50 ft) NEMA - National Electrical Manufacturers Association Most blown fiber systems publish maximum blowing distances of ____________ without employing advanced blowing techniques. - 1 km (3281 ft) ITU G.652D - Singlemode, low water, nondispersion-shifted fiber [NDSF] ITU G.655a and b - Singlemode, nonzero dispersion-shifted fiber (NZDSF) Cable core design -

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

OSP 001 PRACTICE TEST | 100% Correct
Answers | Verified | Latest 2024 Version
in areas where future excavation is anticipated, it may be advisable to place the cable at a greater depth.
For example, if road grading that will remove 610 mm (24 in) of dirt is planned in a particular area, it
would be wiser to initially place the cable at 1.2 m (4 ft) versus the standard

610 mm (24 in). - ✔✔True



placing all of the conduits during the initial conduit system installation is desirable,

if not mandatory.

*True

*False - ✔✔True



It is not always necessary to build new pathways for cable placement

*True

*False - ✔✔True



The length of a cable loop from the switch to a customer depends on three factors - ✔✔• Resistance of
the cable in ohms

• Signaling limits of the telephone and the terminating device switch in ohms

• Pair loading



Outside Plant (OSP) - ✔✔Telecommunications OSP cabling began with the placement of the first
telegraph system,



Cable Types - ✔✔• Optical fiber:

- 62.5/125 micrometer (μm) multimode optical fiber (OM1).

- 50/125 μm multimode optical fiber (OM2, OM3, and OM4).

- Singlemode optical fiber (OS1 and OS2).

,• 100-ohm balanced twisted-pair.

• 75-ohm coaxial.



Codes - ✔✔rules specified by governmental entities



Installation manuals are examples of - ✔✔Methodology



Support structures: - ✔✔- MHs).

- (HHs).

- Poles, support strands, and guying information.



The basic types of OSP pathways and spaces are: - ✔✔• Underground.

• Direct-buried.

• Aerial.



advantage to use optical fiber in backbones campus applications: - ✔✔• Increased distance.

• Higher bandwidth applications.

• All-dielectric cable.

• Less susceptibility to EMI and lightning.

• No crosstalk.

• No grounding (earthing) requirement for all-dielectric cable.



Optical Fiber Connectors: - ✔✔• LC

• SC

• ST



How to calculate passive cable system attenuation - ✔✔Total optical fiber loss

+ Total connector loss

,+ Total splice loss



Calculate link loss budget - ✔✔System gain - Power penalties



Splice loss values - ✔✔MM SM

SP type Avr. max. Avr. max.



Fusion 0.05 0.3 0.05 0.3

Mecha 0.10 0.3 0.10 0.3



Ribbon fiber - ✔✔designs can be single tube or multitube ,the fiber is bound in a flat array



Tight-buffered fibers - ✔✔have a 900 μm coating applied directly to the optical fiber.



A transition point shall be required for unlisted OSP cable when the termination

point is greater than _________ from the point of entrance and the cable cannot

be installed in a properly rated conduit. - ✔✔15 m (50 ft)



NEMA - ✔✔National Electrical Manufacturers Association



Most blown fiber systems publish maximum blowing distances of ____________ without

employing advanced blowing techniques. - ✔✔1 km (3281 ft)



ITU G.652D - ✔✔Singlemode, low water, nondispersion-shifted fiber [NDSF]



ITU G.655a and b - ✔✔Singlemode, nonzero dispersion-shifted fiber (NZDSF)



Cable core design - ✔✔- Filled

, - Dry water block

- Nonfilled



Sheath design - ✔✔- Optical power ground wire (OPGW)

- All-dielectric self-supporting (ADSS)

- Dielectric

- Self-supporting

- Armored self-supporting

- Metallic



Oversheath design - ✔✔- Stainless steel

- Coated steel

- Nothing over sheath

- Self-supporting



Wavelength - ✔✔- Multimode 850/1300 nm

- Singlemode 1310/1550 nm

- Singlemode, dispersion shifted 1550 nm



optical fiber color-code - ✔✔Fiber Color

1 Blue

2 Orange

3 Green

4 Brown

5 Slate

6 White

7 Red

8 Black

Geschreven voor

Vak

Documentinformatie

Geüpload op
3 juli 2024
Aantal pagina's
60
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$9.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
hov
1.0
(2)

Maak kennis met de verkoper

Seller avatar
hov State University Of West Georgia
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
12
Lid sinds
2 jaar
Aantal volgers
3
Documenten
2125
Laatst verkocht
2 maanden geleden
Academic Avengers

Expert Verified Exams {Latest Versions} 99% Pass Rate

1.0

2 beoordelingen

5
0
4
0
3
0
2
0
1
2

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen