100% Correct Answers | Verified | Latest
2024 Version
What are the 4 stages of a fire? - ✔✔Growth, Flashover, Fully Developed, and Decay
What are the 5 Fire Attack Steps? - ✔✔Size up the fire, Attack the fire, Isolate affected
equipment/systems/spaces, Protect compartments exposed to fire, and Set fire and smoke boundaries
What are the 4 Attack methods? - ✔✔Direct Fire Attack, Venting the Fire Compartment, Fog Attack, and
Indirect Fire Attack
Utilizing a Fog Attack, adjusting the nozzle to a medium angle pattern constitutes adjusting the nozzle to
how many degrees? - ✔✔60 degrees
Utilizing a Fog Attack, at what angle should the firefighter point the nozzle? - ✔✔45 degrees above
horizontal
Utilizing a Fog Attack, how long is a short fog burst and how long is the pause that follows? - ✔✔3-5
seconds and 2-3 seconds
In what 5 instances should a Fog Attack be utilized? - ✔✔Out of Control Fires, Rollovers, Seat of fire is
obstructed, Multiple seats of fire present, Delay or prevent flashover during growth stage
If a Fog Attack is not employed properly what is likely to happen? - ✔✔Excessive steam produced forcing
firefighters to withdraw
How is a fire attacked utilizing an Indirect Fire Attack? - ✔✔Water Fog is applied through opening to the
space (i.e. cracked door or penetration)
Whose permission is required to cut holes in bulkheads or overheads? - ✔✔CO's
, An Indirect Fire Attack should immediately be followed by what attack? - ✔✔Direct Attack
During a fire casualty, all electrical equipment should be secured with the exception of what 4 circuits? -
✔✔Lighting, Ventilation, HALON, and AFFF
Electrical equipment should be secured from where during a fire casualty? - ✔✔A Load Center or
Distribution Panel outside of the space
Electrical Isolation should be done by whom? - ✔✔A qualified Repair Party Electrician
Who must make the decision whether to secure or not secure lighting? - ✔✔Scene Leader
The decision to secure ventilation should be made where? - ✔✔On scene
At what point is ventilation typically secured? - ✔✔When fully equipped fire fighters arrive on scene
In regards to smoke boundaries, what should be propositioned at selected doors, hatches, archways, and
hatchways? - ✔✔Smoke curtains and smoke blankets
Active Desmoking is at the discretion of whom? - ✔✔OSL
Who prepares the desmoking flow path? - ✔✔Locker Leader
Who approves and directs active desmoking? - ✔✔Repair Party Leader
When re-entering a space on which side of the door should firefighters be positioned? - ✔✔On the non-
hinge side