Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

EPA Section 608 Technician Certification Study Guide 100% Correct Answers Verified Latest 2024 Version

Rating
-
Sold
-
Pages
27
Grade
A+
Uploaded on
03-07-2024
Written in
2023/2024

What are the typical uses of the center port of gauge set? - Used during evacuation, charging and recovery procedures. What color are the gauges on a manifold gauge set? - Low pressure is blue, High pressure is red. What are the typical ranges of pressure measurements used on the gauges of a manifold gauge set? - High side is 0 to 500 PSIG; Low side is 0 to 350 PSIG and 0 to 30 in. Hg below atmospheric pressure. Is the refrigerant leaving a condenser at a high or low pressure? Is it a liquid or a gas? - High pressure, liquid. Is the refrigerant entering the expansion valve (variable metering device) a liquid or gas? - Liquid, high pressure. Is the pressure of the refrigerant entering the compressor high or low? - Low pressure vapor. Where in a refrigerant circuit does a liquid boil to absorb heat? - In the evaporator. The refrigerant in the suction line is a gas that has been heated above its saturation. What is this condition called? - Superheated vapor. What can cause liquid refrigerant to migrate to a compressor crankcase? - If the compressor is located in the coldest location in the circuit. List two conditions that can quickly damage a compressor that is starting to run? - Operating while in a deep vacuum or when the service valves are closed.What system failures require taking an oil sample? - A compressor burnout or if the unit has had a leak. Is flushing with refrigerant an acceptable tube cleaning method? - No. In addition to preventing and repairing leaks what else should a technician do to conserve refrigerant? - Recover and recycle used refrigerants. What factors affect the speed of an evacuation? - Pump size, hose length, hose diameter, size of system to be evacuated, ambient temperature, suction line size, and the amount of moisture in the system. How should gauge set hoses be sized for use in evacuating a system? - Use the shortest length and the largest diameter possible for the quickest evacuation. At least as large as the vacuum pump inlet. When evacuating what is the benefit of using short hoses with large diameters? - Reduces emissions, pressure drop and evacuation time. Which connection determines the preferred size of hoses used with a vacuum pump? - The vacuum pump inlet. As the capacity and suction hose size increase what happens to the time needed for an evacuation? - Time is reduced. What purpose is served by heating a system during dehydration? - To speed up moisture removal. Does a thorough evacuation remove moisture from a system? - Yes. What can happen to oil in the compressor if the moisture is left in an operating system? - The oil will form hydrofluoric and hydrochloric acids which will corrode the internal parts of the system.What is the result of over-evacuating a system? - No damage will be done. How can a system be leak checked using a low pressure gauge? - Vacuum reading will rise when vacuum pump is turned off. How close should the vacuum gauge be connected to the vacuum pump during evacuation? - As far away as possible. When measuring the vacuum of a system being evacuated the system must be isolated. What must be done to the vacuum pump? - Turn it off and valve it off. What is ozone? - 3 atoms of oxygen. It blocks much of the harmful ultraviolet radiation (uv-b) emitted from the sun and it keeps our earth's temperature stable. How much ozone can a chlorine atom destroy in the stratosphere? - One atom can destroy 100,000 ozone molecules. What is Ozone Depletion Potential (ODP)? - The ability of any chemical to deplete the ozone layer. What is CFC? - Chlorofluorocarbon. Which refrigerants are CFC's? - R-11,12,113,114. Which chemical in the CFC refrigerants does the most damage to the ozone layer? - Chlorine. What is an HCFC? - Hydrochlorofluorocarbons. Which refrigerants are HCFC's? - R-22,123.

Show more Read less
Institution
Course

Content preview

EPA Section 608 Technician Certification
Study Guide | 100% Correct Answers |
Verified | Latest 2024 Version
What are the typical uses of the center port of gauge set? - ✔✔Used during evacuation, charging and
recovery procedures.



What color are the gauges on a manifold gauge set? - ✔✔Low pressure is blue, High pressure is red.



What are the typical ranges of pressure measurements used on the gauges of a manifold gauge set? -
✔✔High side is 0 to 500 PSIG; Low side is 0 to 350 PSIG and 0 to 30 in. Hg below atmospheric pressure.



Is the refrigerant leaving a condenser at a high or low pressure? Is it a liquid or a gas? - ✔✔High
pressure, liquid.



Is the refrigerant entering the expansion valve (variable metering device) a liquid or gas? - ✔✔Liquid,
high pressure.



Is the pressure of the refrigerant entering the compressor high or low? - ✔✔Low pressure vapor.



Where in a refrigerant circuit does a liquid boil to absorb heat? - ✔✔In the evaporator.



The refrigerant in the suction line is a gas that has been heated above its saturation. What is this
condition called? - ✔✔Superheated vapor.



What can cause liquid refrigerant to migrate to a compressor crankcase? - ✔✔If the compressor is
located in the coldest location in the circuit.



List two conditions that can quickly damage a compressor that is starting to run? - ✔✔Operating while in
a deep vacuum or when the service valves are closed.

,What system failures require taking an oil sample? - ✔✔A compressor burnout or if the unit has had a
leak.



Is flushing with refrigerant an acceptable tube cleaning method? - ✔✔No.



In addition to preventing and repairing leaks what else should a technician do to conserve refrigerant? -
✔✔Recover and recycle used refrigerants.



What factors affect the speed of an evacuation? - ✔✔Pump size, hose length, hose diameter, size of
system to be evacuated, ambient temperature, suction line size, and the amount of moisture in the
system.



How should gauge set hoses be sized for use in evacuating a system? - ✔✔Use the shortest length and
the largest diameter possible for the quickest evacuation. At least as large as the vacuum pump inlet.



When evacuating what is the benefit of using short hoses with large diameters? - ✔✔Reduces emissions,
pressure drop and evacuation time.



Which connection determines the preferred size of hoses used with a vacuum pump? - ✔✔The vacuum
pump inlet.



As the capacity and suction hose size increase what happens to the time needed for an evacuation? -
✔✔Time is reduced.



What purpose is served by heating a system during dehydration? - ✔✔To speed up moisture removal.



Does a thorough evacuation remove moisture from a system? - ✔✔Yes.



What can happen to oil in the compressor if the moisture is left in an operating system? - ✔✔The oil will
form hydrofluoric and hydrochloric acids which will corrode the internal parts of the system.

, What is the result of over-evacuating a system? - ✔✔No damage will be done.



How can a system be leak checked using a low pressure gauge? - ✔✔Vacuum reading will rise when
vacuum pump is turned off.



How close should the vacuum gauge be connected to the vacuum pump during evacuation? - ✔✔As far
away as possible.



When measuring the vacuum of a system being evacuated the system must be isolated. What must be
done to the vacuum pump? - ✔✔Turn it off and valve it off.



What is ozone? - ✔✔3 atoms of oxygen. It blocks much of the harmful ultraviolet radiation (uv-b)
emitted from the sun and it keeps our earth's temperature stable.



How much ozone can a chlorine atom destroy in the stratosphere? - ✔✔One atom can destroy 100,000
ozone molecules.



What is Ozone Depletion Potential (ODP)? - ✔✔The ability of any chemical to deplete the ozone layer.



What is CFC? - ✔✔Chlorofluorocarbon.



Which refrigerants are CFC's? - ✔✔R-11,12,113,114.



Which chemical in the CFC refrigerants does the most damage to the ozone layer? - ✔✔Chlorine.



What is an HCFC? - ✔✔Hydrochlorofluorocarbons.



Which refrigerants are HCFC's? - ✔✔R-22,123.

Written for

Course

Document information

Uploaded on
July 3, 2024
Number of pages
27
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$8.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller
Seller avatar
hussle

Get to know the seller

Seller avatar
hussle Harvard College
Follow You need to be logged in order to follow users or courses
Sold
1
Member since
1 year
Number of followers
1
Documents
1635
Last sold
1 year ago
A+ ExamPrep Essentials

Explore my collection of high quality study guides and exam prep materials. Whether you\\\'re striving for top grades or looking to understand complex topics better, I provide: .Detailed Study Guide .Exam-ready notes .practice Tests .Subject coverage

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions