California UST Service Technician part 1

July 1 2005, service techs shall possess or work under someone who has a current
certification indicating he or she has passed the ? - ANS-California UST service
technician exam

ICC cert must be renewed every? - ANS-24 months

Service techs must posses or be employed by a person who has the appropriate
contractors license unless? - ANS-The individual has a Tank testing licens

Service tech is defined by any individual who? - ANS-Test UST monitoring equipment
Trouble shoots UST systems
Installs UST monitoring equipment

If the manufacturer training no longer exist , the local angency may? - ANS-Approve
comparable alternat training .

UST includes? - ANS-Tank and connected piping

What is considered and UST - ANS-petroleum storage tank

What UST system meets the requirements for secondary containment? - ANS-Doubled
wall tanks

According to title 23; the following piping components if installed after July 1 1987 must
have secondary containment - ANS-Pressured product piping

Considered "pipe" on tanks installed after July 1 2003 - ANS-Pressured product piping
and below ground vapor recovery

Under dispenser containment (UDC) was required for all UST systems by -
ANS-December 31 2003

System for exchanging gas vapors in a storage tank and product in a fuel delivery truck
- ANS-Stage 1 vapor recovery

, An approved method for non visual monitoring for existing UST systems. -
ANS-Statistical Inventory Reconciliation (SIR)

ATG must be capable for detecting a release of ? - ANS-.2 gallons per hour

Manual inventory reconciliation. - ANS-No longer an approved method for non visual
monitoring on existing UST systems

Automatic line leak detectors installed on underground piping with secondary
containment shall be capable of tetecting a leak of ? - ANS-3 gallons per hour at 10 psi

ATG should be programmed to test the tank ? - ANS-At least monthly

According to PEI RP 300 a combustible gas can be used to ? - ANS-Detect vapor leaks
in a vapor recovery system.

According to PEI RP 300. A written scope of work for vapor recovery installation should
include? - ANS-Construction plans

Positive shut off overfill protection device must stop the flow of fuel when the tank is no
more then ? - ANS-95% full

According to EO VR 201 A What could cause a nozzle shut off mechanism or
malfunction? - ANS-Depended filter seal damage

According to VR 201 A Breakaway reconnection must be ? - ANS-Logged in GDF log

According to PEI RP 300 the following method of documenting piping location is NOT to
? - ANS-Sketch a diagram on the inside cover of vapor recovery equipment manual

According to PEI RP 300 as built drawing or pictures of the underground pipping and
other components shall be ? - ANS-Maintained as long as UST is in service

According to EO VR 101 E maintance records are required to include? - ANS-Name
and designated UST operator .

The Phil-Tite EVR phase 1 system require that vapor vent pipes at any UST system be -
ANS-Used with no more then 3 p/v valves

Geschreven voor

Vak

Documentinformatie

Geüpload op
4 juli 2024
Aantal pagina's
5
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$8.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
GOLDSOLUTIONS Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
12384
Lid sinds
2 jaar
Aantal volgers
61
Documenten
17415
Laatst verkocht
2 dagen geleden

4.5

123 beoordelingen

5
93
4
10
3
10
2
4
1
6

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen