Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

FDNY S-92 Questions with 100% Correct Answers Latest Version 2024 Verified

Beoordeling
-
Verkocht
-
Pagina's
11
Cijfer
A+
Geüpload op
04-07-2024
Geschreven in
2023/2024

The following are types of what? LPG, CNG, piped natural gas or solid fuel (coke). - Portable fueled salamanders/space heaters National Institute for Occupational Safety and Health (NIOSH) Recommended Exposure Limit (REL) for carbon monoxide - 35 parts per million (ppm) over an 8 hour period What is the third leading cause of fires in buildings under construction ? - temporary heating What is direct heat flow through matter? - CONDUCTION What is the transport of heat within a gas or liquid caused by the actual flow of the material itself - CONVECTION the transmission of electromagnetic rays through space. - Radiation Heaters that release all of the heat generated by the flame (and the emissions that result) directly into the heated area - Direct-fired heaters What are the most common type of heater found at construction sites? - Direct-fired heaters The flame of this heater is enclosed in a heat exchanger that separates combustion products from the air to be heated. - Indirect-Fired HeatersWhen may portable oil-fueled space heaters be stored, handled and used at construction sites - only during the heating season (October 15th - May 30th). A fail-safe system or other approved device, equipment or system designed to shut off flow caused by a rupture in a pressurized piping system. - EXCESS FLOW CONTROL A liquefied compressed gas which, under a charged pressure, is partially liquid at a temperature of 68°F (20°C) and which is a flammable gas. - FLAMMABLE LIQUEFIED GAS supervision by the holder of any department certificate who is responsible but need not be personally present on the premises at all times - GENERAL SUPERVISION A material having a melting point that is equal to or less than 68°F (20°C) and a boiling point that is greater than 68°F (20°C) at 14.7 psia (101 kpa). - LIQUID The minimum concentration of vapor in air at which propagation of flame will occur in the presence of an ignition source. The LFL is sometimes referred to as LEL or lower explosive limit - LOWER FLAMMABLE LIMIT (LFL) The transfer of flammable or combustible liquids between cargo tanks or tank cars and containers, tanks piping and other equipment that is to be used in process operations. - PROCESS TRANSFER what shall be on site and available for inspection at all times? - All FDNY original permits A method of supervision by the holder who is

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

FDNY S-92 Questions with 100% Correct
Answers | Latest Version 2024 | Verified
The following are types of what? LPG, CNG, piped natural gas or solid fuel (coke). - ✔✔Portable fueled
salamanders/space heaters



National Institute for Occupational Safety and Health (NIOSH) Recommended

Exposure Limit (REL) for carbon monoxide - ✔✔35 parts per million (ppm) over an 8 hour period



What is the third leading cause of fires in buildings under

construction ? - ✔✔temporary heating



What is direct heat flow through matter? - ✔✔CONDUCTION



What is the transport of heat within a gas or liquid caused by the

actual flow of the material itself - ✔✔CONVECTION



the transmission of electromagnetic rays through space. - ✔✔Radiation



Heaters that release all of the heat generated by the flame (and the

emissions that result) directly into the heated area - ✔✔Direct-fired heaters



What are the most common type of heater found at construction

sites? - ✔✔Direct-fired heaters



The flame of this heater is enclosed in a heat exchanger that separates combustion products from the air
to be heated. - ✔✔Indirect-Fired Heaters

, When may portable oil-fueled space heaters be stored, handled and used at

construction sites - ✔✔only during the heating season (October 15th - May 30th).



A fail-safe system or other approved device,

equipment or system designed to shut off flow caused by a rupture in a

pressurized piping system. - ✔✔EXCESS FLOW CONTROL



A liquefied compressed gas which, under a charged pressure, is partially liquid at a temperature of 68°F
(20°C) and which is a flammable gas. - ✔✔FLAMMABLE LIQUEFIED GAS



supervision by the holder of any department certificate who is responsible but need not be personally
present on the premises at all times - ✔✔GENERAL SUPERVISION



A material having a melting point that is equal to or less than 68°F (20°C) and a boiling point that is
greater than 68°F (20°C) at 14.7 psia (101

kpa). - ✔✔LIQUID



The minimum concentration of vapor in

air at which propagation of flame will occur in the presence of an ignition

source. The LFL is sometimes referred to as LEL or lower explosive limit - ✔✔LOWER FLAMMABLE LIMIT
(LFL)



The transfer of flammable or combustible liquids

between cargo tanks or tank cars and containers, tanks piping and other

equipment that is to be used in process operations. - ✔✔PROCESS TRANSFER



what shall be on

site and available for inspection at all times? - ✔✔All FDNY original permits



A method of supervision by the holder who is

Geschreven voor

Vak

Documentinformatie

Geüpload op
4 juli 2024
Aantal pagina's
11
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$8.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
hussle

Maak kennis met de verkoper

Seller avatar
hussle Harvard College
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
1
Lid sinds
1 jaar
Aantal volgers
1
Documenten
1635
Laatst verkocht
1 jaar geleden
A+ ExamPrep Essentials

Explore my collection of high quality study guides and exam prep materials. Whether you\\\'re striving for top grades or looking to understand complex topics better, I provide: .Detailed Study Guide .Exam-ready notes .practice Tests .Subject coverage

0.0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen