What size syringe is needed to inflate a size 1 laryngeal mask? - CORRECT
ANSWERS-5mL
What size orogastric tube do you need at the warmer if an insertion port is
present on a laryngeal mask? - CORRECT ANSWERS-5F or 6F
At the warmer you should have accessed to what type of monitor and leads? - CORRECT ANSWERS-Cardiac
Should you have equipment for free flow oxygen available at the warmer? - CORRECT ANSWERS-Yes
To check oxygen at the warmer you should have what sensor and it's cover? - CORRECT ANSWERS-Pulse oximeter
What cheat sheet or oxygen should you have at the warmer? - CORRECT ANSWERS-Target oxygen saturation table
What size straight blades should you have with laryngoscopes? - CORRECT
ANSWERS-Size-0 and size-1 (size 00 is optional)
Is a stylet optional for intubation supplies at the warmer? - CORRECT ANSWERS-Yes
What size endotracheal tubes should be at the warmer? - CORRECT ANSWERS-2.5, 3.0, and 3.5
Should a CO2 detector be at the warmer? - CORRECT ANSWERS-Yes
If there is not an endotracheal tube insertion depth table at the warmer, there should be a? - CORRECT ANSWERS-Measuring tape
If there's is not a tube securing device at the warmer there should be? - CORRECT ANSWERS-Waterproof tape
Should there be scissors at the warmer? - CORRECT ANSWERS-Yes