CHL IAHCSMM Chps 22-25 Questions And Answers With Verified Solutions Graded A+
Biobarrier - A package system that allows a sterilant to enter a pack and after sterilization, creates a barrier to contamination. Catalog number - This quick reference can help when ordering replacement instruments from specified vendors. Cost containment - The process of controlling inefficiencies in consumption, allocation or production of services that contribute to higher that necessary costs is called: Extended cycle - Sterilization cycles that fall outside of the traditional cycles used in the Central Service department because exposure times exceed standard steam sterilization times. Extending sterilization cycles - While some sterilization failures result from mechanical failures over which the technician has no control, many failures can be avoided by: False - A steam sterilizer can successfully sterilize anything placed in it. False - Well-managed departments are not impacted by the grapevine. Firewall - A network link through which only authorized data can pass that keeps computers safe from hackers and hardware failures that occur elsewhere FMEA (Failure Mode and Effect Analysis - A process used to predict the adverse outcomes of various human and machine failures. Lot (load) control number - Number and /or letters by which a specific group of products can be traced to a particular manufacturing or sterilization operation.Master budget - This budget predicts the healthcare facility's total revenue and expenses for a specified period of time. Personnel budget - Costs for labor are addressed in a: Prions - Cause for special concern in CS because routine reprocessing processes are not enough to protect patients. Qualification - Testing that assesses the performance of a steam sterilizer in the environment in which it will be used before the equipment is approved for routine use in the healthcare facility. Six Sigma - A quality process that focuses on developing near-perfect products and services. Steam traps - These are installed on the steam distribution line to help remove condensation. Validation - Documented procedures performed by a medical device manufacturer to establish that a process consistently yields a product complying with predetermined specifications. Verification - Documented procedures performed in the users environment to establish that predetermined specifications have been met. Wet pack - Trays/containers containing moisture after the sterilization process is complete Zero - based budget - An approach to budget preparation that requires planners to explain all expenses and provide justification for each line item funded with resources allocated accordingly.
Geschreven voor
- Instelling
- CHL IAHCSMM Chps 22-25
- Vak
- CHL IAHCSMM Chps 22-25
Documentinformatie
- Geüpload op
- 28 juli 2024
- Aantal pagina's
- 2
- Geschreven in
- 2023/2024
- Type
- Tentamen (uitwerkingen)
- Bevat
- Vragen en antwoorden
Onderwerpen
-
chl iahcsmm chps 22 25