BACKFLOW PREVENTION ASSEMBLY TESTER EXAM WITH LATEST QUESTIONS AND CORRECT ANSWERS ALREADY GRADED A+ Backsiphonage - ANS-A backflow condition in which the pressure in the distribution system is less than atmospheric pressure (subatmospheric) Auxiliary Supply (Reclaimed Water) - ANS-Any water source or system, other than the potable water supply, that may be available in the building or premise. Primary consideration when deciding on DC or RP - ANS-Degree of Hazard When testing an RP, the #1 SOV - ANS-is to be left open at all times Containment Protection - ANS-Protects all consumers on a Public Water System Vacuum - ANS-Any pressure less than that exerted by the atmosphere Internal Protection - ANS-The backflow device at the point of use How much does 1 cubic foot of water weigh - ANS-62.4 pounds How much does one gallon of water weigh - ANS-8.3 pounds An RP is not required at the service connection of - ANS-A single family dwelling A perfect vacuum a see level will raise the water level in a pipe a maximum of - ANS-33.9 feet A mixture of air and gas is considered to become hazardous when it exceeds ___ of the lower explosive limit - ANS-10% Vacumm - ANS-Any pressure less than that exerted by the atmosphere Backpressure & Backsiphonage - ANS-Backflow occurs because of what two things maximum distance that an absolute vacuum breaker at sea level will lift a column of water is - ANS-33.9 feet This amount of absolute pressure could cause backsiphonage to occur in a hydraulic system - ANS-10.5 psia When testing DC and the #2 check valve is leaking you must - ANS-Repair the #2 check Each check valve on a DC is designed to hold - ANS-1.0 psid Maximum absolute pressure loss for a DC is - ANS-10 psi Air Inlet on a PVB must open at or above - ANS-1 psid

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

BACKFLOW PREVENTION ASSEMBLY
TESTER EXAM 2024-2025 WITH LATEST
QUESTIONS AND CORRECT ANSWERS
ALREADY GRADED A+




Backsiphonage - ANS-A backflow condition in which the pressure in the distribution system is less than
atmospheric pressure (subatmospheric)



Auxiliary Supply (Reclaimed Water) - ANS-Any water source or system, other than the potable water
supply, that may be available in the building or premise.

Primary consideration when deciding on DC or RP - ANS-Degree of Hazard



When testing an RP, the #1 SOV - ANS-is to be left open at all times



Containment Protection - ANS-Protects all consumers on a Public Water System



Vacuum - ANS-Any pressure less than that exerted by the atmosphere

Internal Protection - ANS-The backflow device at the point of use

Geschreven voor

Vak

Documentinformatie

Geüpload op
14 augustus 2024
Aantal pagina's
3
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$22.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
Shimwai126

Maak kennis met de verkoper

Seller avatar
Shimwai126 All
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
1
Lid sinds
2 jaar
Aantal volgers
1
Documenten
487
Laatst verkocht
1 jaar geleden

0.0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen