The document titled **"Computed Tomography for Technologists: 2nd Edition Exam Review"** serves as an essential resource for professionals in the field of radiologic technology, specifically those preparing for certification exams in computed tomography (CT). This comprehensive review guide is designed to enhance the knowledge and skills of technologists, ensuring they are well-prepared for both practical applications and theoretical assessments. ## Overview of Content The document is structured to cover a wide range of topics critical to understanding CT technology. It includes detailed explanations of key concepts such as: - **Image Acquisition Techniques**: The guide discusses various scanning methods, including axial and helical scanning, emphasizing their advantages and disadvantages. It also explains the importance of parameters like slice thickness, pitch, and scan time in optimizing image quality and patient safety. - **Technical Fundamentals**: Readers will find in-depth discussions on the physics of CT imaging, including beam attenuation, Hounsfield units, and the role of contrast media. This foundational knowledge is crucial for technologists to interpret images accurately and understand the underlying principles of CT technology. - **Image Processing and Reconstruction**: The document highlights the processes involved in converting raw data into diagnostic images, including algorithms and filtering techniques. It explains how these processes affect image quality and diagnostic accuracy. - **Radiation Safety**: A significant focus is placed on minimizing radiation exposure to patients while maximizing image quality. The guide outlines best practices for radiation dose management, which is essential for ethical and safe imaging practices. - **Clinical Applications**: The review includes practical scenarios and case studies that illustrate the application of CT in various medical settings. This contextual information helps technologists understand how to apply their knowledge in real-world situations. ## Features That Enhance Readability and Engagement - **Question and Answer Format**: The document employs a Q&A format that mimics the style of certification exams, allowing readers to test their knowledge and identify areas for improvement. This interactive approach increases engagement and retention of information. - **Visual Aids**: Diagrams and illustrations are included to clarify complex concepts, making the material more accessible to visual learners. - **Comprehensive Review Questions**: At the end of each section, review questions reinforce learning and provide a self-assessment tool for readers. ## Target Audience This document is ideal for: - **Radiologic Technologists**: Those seeking to specialize in CT imaging and enhance their certification prospects. - **Students in Radiologic Technology Programs**: Individuals preparing for their exams who require a thorough review of CT principles and practices. - **Healthcare Professionals**: Other medical personnel interested in understanding the role of CT in diagnostics and patient care. ## Conclusion "Computed Tomography for Technologists: 2nd Edition Exam Review" is a vital tool for anyone involved in the field of radiologic technology. Its structured approach, comprehensive content, and practical focus make it an invaluable resource for exam preparation and professional development. By investing in this guide, readers can enhance their knowledge, improve their clinical skills, and ultimately contribute to better patient outcomes in the realm of medical imaging.

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

Computed Tomography for
Technologists 2nd Edition Exam Review
Which is NOT a synonym for the preliminary/localizer image taken at the start of a CT
examination?
A. Topogram
B. Scout
C. Scanogram
D. Spiral - ANSWER: D. Spiral

The ability of a system to differentiate, on the image, objects with similar densities is
known as:
A. High contrast resolution
B. Low contrast resolution
C. Spatial resolution
D. Temporal resolution - ANSWER: B. Low contrast resolution

Each two dimensional square of data that make up the CT image is called a:
A. Pixel
B. Voxel
C. Matrix
D. Fragment - ANSWER: A. Pixel

How many pixels are contained in a 1,024 matrix image? A. 1,024
B. 2,048
C. 262,144
D. 1,048,576 - ANSWER: D. 1,048,576

Beam attenuation can be defined as:
A. The phenomenon by which artifacts result when lower energy photons are
preferentially absorbed, leaving only higher-intensity photons to strike the detector
array.
B. Xray energy that is produced from bombarding a substance with fast moving
electrons.
C. The ability of the detector to capture transmitted photons and change them to
electronic signals.
D. The phenomenon by which an xray beam passing through a structure is decreased
in intensity or amount because of absorption and interaction with matter. - ANSWER: D.
The phenomenon by which an xray beam passing through a structure is decreased in
intensity or amount because of absorption and interaction with matter.

Which of the following is a low attenuation structure:
A. Iodine filled aorta
B. Rib

,C. Trachea
D. Calcified arteries - ANSWER: C. Trachea

An object is slightly less dense than water. What is the expected hounsfield
measurement?
A. -940
B. -10
C. 50
D. 850 - ANSWER: B. -10

Why does the administration of iodinated contrast media result in an enhanced image?
A. Iodinated contrast material increases the ability of the enhanced structure to
attenuate the xray beam.
B. Iodinated contrast material decreases the average photon energy of the xray beam;
therefore more photons are absorbed by the patient.
C. The administration of contrast material results in a smaller pixel, thereby increasing
spatial resolution, which results in an enhanced image.
D. - ANSWER: A. Iodinated contrast material increases the ability of the enhanced
structure to attenuate the xray beam.

The xray beam sources for CT produce xray energy that is polychromatic. This means:
A. When viewed by the naked eye, the beam exhibits many different colors.
B. It produce, as a byproduct, a substance known as polychlorinated biphenyl.
C. Photons contained in the beam are all of the same wavelength.
D. The beam comprises photons with varying energies. - ANSWER: D. The beam
comprises photons with varying energies.

An object that appears on the image but is not present in the object scanned is called
a/n:
A. Artifact
B. Anomaly
C. Shadow
D. Ghost - ANSWER: A. Artifact

Which is an advantage of filtering the xray beam?
A. Filtering reduces the anode heat load
B. A filtered beam produces images with substantially less quantum mottle
C. Filtering the beam prevents energy from being converted to heat, therefore 100% of
the energy is converted to xrays.
D. Filtering reduces the radiation dose to the patient. - ANSWER: D. Filtering reduces
the radiation dose to the patient

Scan thickness is primarily important for the part it plays in:
A. Noise reduction
B. The contrast scale
C. Detector aperture opening

,D. Volume averaging - ANSWER: D. Volume averaging

You are working with the radiologist to establish examination protocols for your
department. Which of the following is a logical consideration when determining an
appropriate slice thickness for studies of the internal auditory canal?
A. Because the auditory ossicles are quite small, a thin slice will be necessary to reduce
the chance that volume averaging will obscure their appearance on the image.
B. The appropriate slice thickness will vary considerably from patient to patient.
Therefore, each technologist should be free to adjust the slice thickness as he or she
deems necessary for the particular patient.
C. A slice thickness of 5 to 7mm is adequate because the structures of interest are not
particularly small and the examination is most often ordered as a screening study for
asymptomatic patients.
D. The thickest slice available should be used to reduce the radiation dose to the
corneas. - ANSWER: A. Because the auditory ossicles are quite small, a thin slice will
be necessary to reduce the chance that volume averaging will obscure their appearance
on the image.

How many CT numbers are assigned to each pixel in the image matrix?
A. One half the number of all values recorded from the detector array
B. One
C. The number of HU per pixel is one tenth the display field of view
D. Two values for a 256 matrix; 4 values for a 512 matrix - ANSWER: B. One

Which is another name for raw data?
A. Image data
B. Scan data
C. Reconstructed data
D. Displayed data - ANSWER: B. Scan data

When in the anatomic position, the arms are:
A. raised above the head, palms backwards
B. crossed over the chest, palms on opposite shoulders
C. down by the sides, palms forward
D. by the sides, elbows bent, palms backward and resting on hips - ANSWER: C. down
by the sides, palms forward

Which of the following components is NOT housed within the gantry?
A. Three phase generator
B. High-frequency generator
C. Slip rings
D. Xenon gas detectors - ANSWER: A. Three phase generator

The power capacity of the generator is listed in:
A. milliamperes (mA)
B. thousand heat units (KHU)

, C. million heat units (MHU)
D. kilowatts (kW) - ANSWER: D. kilowatts (kW)

Which of the following describes a slip ring device?
A. A recoiling system cable used to rotate the gantry frame
B. A brushlike apparatus that provides continuous electrical power and electronic
communication across a rotating surface
C. A device used to shape the xray beam, thereby reducing the radiation dose to the
patient and reducing image artifact
D. A device that restricts the xray beam emerging from the gantry to thin ribbons -
ANSWER: B. A brushlike apparatus that provides continuous electrical power and
electronic communication across a rotating surface

Which is a disadvantage of a small focal spot size?
A. Reduced spatial resolution
B. Reduced detector efficiency
C. Increased penumbra
D. Reduced heat capacity - ANSWER: D. Reduced heat capacity

The ability of the tube to withstand by product heat is called:
A. heat capacity
B. heat dissipation
C. thermal potential
D. thermal transference - ANSWER: A. Heat capacity

Regarding the detectors in the CT system, geometric efficiency is controlled primarily
by:
A. detector material
B. type of photodiode used
C. filtration
D. detector spacing and aperture - ANSWER: D. Detector spacing and aperture

Which of the following is a characteristic of xenon gas detectors?
A. Low efficiency
B. Sensitive to temperature and moisture
C. May exhibit afterglow
D. Also called scintillators - ANSWER: A. Low efficiency

Which component of the CT system converts the electric signal supplied by the
detectors into a digital format?
A. Photodiode
B. Array processor
C. Display processor
D. Analog to digital converter - ANSWER: D. Analog to digital converter

Geschreven voor

Vak

Documentinformatie

Geüpload op
18 augustus 2024
Aantal pagina's
32
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$23.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
mosemgitete
3.0
(1)

Maak kennis met de verkoper

Seller avatar
mosemgitete Princeton University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
1
Lid sinds
2 jaar
Aantal volgers
0
Documenten
50
Laatst verkocht
1 jaar geleden

3.0

1 beoordelingen

5
0
4
0
3
1
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen