2024 OSP-001 PRACTISE TEST
EXAM WITH CORRECT ANSWERS

in areas where future excavation is anticipated, it may be advisable to place
the cable at a greater depth. For example, if road grading that will remove
610 mm (24 in) of dirt is planned in a particular area, it would be wiser to
initially place the cable at 1.2 m (4 ft) versus the standard
610 mm (24 in). - CORRECT-ANSWERSTrue

OSP designers need to give special consideration to telecommunications
services at ______ - CORRECT-ANSWERSmarinas

OSP designers need to give special consideration to telecommunications
services at marinas because of the following unique conditions: - CORRECT-
ANSWERS• Changing water levels
• High moisture and humidity
• Severe weather (e.g., winds, waves, sun)
• Potential for deterioration of the distribution cable ( cable damage )
• Salt (corrosive environment)
• Transience of boat owners ( temporary )
• Difficulty in establishing a dependable and approved electrical grounding
point

The space reserved for a boat adjacent to a dock is _______ - CORRECT-
ANSWERSBoat slip

A portion of a dock that is publicly accessible to all marina users is call
________ - CORRECT-ANSWERSCommon element

placing all of the conduits during the initial conduit system installation is
desirable,
if not mandatory.
*True
*False - CORRECT-ANSWERSTrue


A portion of a dock that is accessible only to those boat
slips that it serves on either side is call ________ - CORRECT-ANSWERSLimited
common element (LCE)

A boat slip that is owned or subleased is ________ - CORRECT-
ANSWERSCondominium slip

,To accommodate the movement of a floating dock to and from a shoreline,
the following arrangements should be used: - CORRECT-ANSWERS• Hose-
reeling cable on a floating section
• A point of connection at both ends of a dock section to ease adding or
removing sections
of cable
• Jack and plug arrangements for smaller installations that need only a few
service cables
• Cables placed in a festoon arrangement, similar to the festooned cables
placed on
bleachers that are retracted and expanded

It is known in advance that all or most of the boat slips require
telecommunications services - CORRECT-ANSWERSPrecable each boat slip
during construction of the dock. For security, each run should be terminated
in the patch panel cross-connect at the dock master or marina office.

Fewer than 10 boat slips are cabled - CORRECT-ANSWERSRun one- or two-
pair cables from the boat slips to a distribution terminal on the closest point
of land.

If 10 or more boat slips are cabled - CORRECT-ANSWERSPlace distribution
cable onto the dock and terminate in a suitable cabinet or enclosure. Run
service drop to each boat slip.

All cable splices should be mechanically protected from the harsh
environment using: - CORRECT-ANSWERS• Conduit.
• Cable trays.
• Weatherproof enclosures.
• Other structures suited for harsh, outdoor conditions.

______ cable on docks should be used. - CORRECT-ANSWERSWater-blocked

in marinas the type and size of conduit can be selected following these
guidelines: - CORRECT-ANSWERS• Use rigid nonmetallic conduit wherever
possible.
• Join the sections of rigid conduit with flexible duct where movement of a
dock is probable.
• Use minimum 21 mm (3/4 trade size) conduits for service cables to each
slip.

a common telecommunications conduit within a prefabricated dock section
might be the only available cabling medium: - CORRECT-ANSWERS• In areas
where direct local exchange service and public telephone service are
provided by

,different companies.
• Where CATV is requested.

When an individual boat slip is owned and subleased as a regular
condominium, only the two bordering boat slip owners can legally use a
finger slip, a limited common element.

True
False - CORRECT-ANSWERSTrue


It is not always necessary to build new pathways for cable placement
*True
*False - CORRECT-ANSWERSTrue

The length of a cable loop from the switch to a customer depends on three
factors - CORRECT-ANSWERS• Resistance of the cable in ohms
• Signaling limits of the telephone and the terminating device switch in ohms
• Pair loading

Outside Plant (OSP) - CORRECT-ANSWERSTelecommunications OSP cabling
began with the placement of the first telegraph system,

Cable Types - CORRECT-ANSWERS• Optical fiber:
- 62.5/125 micrometer (μm) multimode optical fiber (OM1).
- 50/125 μm multimode optical fiber (OM2, OM3, and OM4).
- Singlemode optical fiber (OS1 and OS2).
• 100-ohm balanced twisted-pair.
• 75-ohm coaxial.

Codes - CORRECT-ANSWERSrules specified by governmental entities

Installation manuals are examples of - CORRECT-ANSWERSMethodology

Support structures: - CORRECT-ANSWERS- MHs).
- (HHs).
- Poles, support strands, and guying information.

The basic types of OSP pathways and spaces are: - CORRECT-ANSWERS•
Underground.
• Direct-buried.
• Aerial.

advantage to use optical fiber in backbones campus applications: -
CORRECT-ANSWERS• Increased distance.
• Higher bandwidth applications.

, • All-dielectric cable.
• Less susceptibility to EMI and lightning.
• No crosstalk.
• No grounding (earthing) requirement for all-dielectric cable.

Optical Fiber Connectors: - CORRECT-ANSWERS• LC
• SC
• ST

How to calculate passive cable system attenuation - CORRECT-
ANSWERSTotal optical fiber loss
+ Total connector loss
+ Total splice loss

Calculate link loss budget - CORRECT-ANSWERSSystem gain - Power
penalties

Splice loss values - CORRECT-ANSWERSMM SM
SP type Avr. max. Avr. max.

Fusion 0.05 0.3 0.05 0.3
Mecha 0.10 0.3 0.10 0.3

Ribbon fiber - CORRECT-ANSWERSdesigns can be single tube or
multitube ,the fiber is bound in a flat array

Tight-buffered fibers - CORRECT-ANSWERShave a 900 μm coating applied
directly to the optical fiber.

A transition point shall be required for unlisted OSP cable when the
termination
point is greater than _________ from the point of entrance and the cable
cannot
be installed in a properly rated conduit. - CORRECT-ANSWERS15 m (50 ft)

NEMA - CORRECT-ANSWERSNational Electrical Manufacturers Association

Most blown fiber systems publish maximum blowing distances of ____________
without
employing advanced blowing techniques. - CORRECT-ANSWERS1 km (3281
ft)

ITU G.652D - CORRECT-ANSWERSSinglemode, low water, nondispersion-
shifted fiber [NDSF]

Written for

Institution
OSP-001
Course
OSP-001

Document information

Uploaded on
August 22, 2024
Number of pages
48
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$20.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Elitaa Chamberlain university
Follow You need to be logged in order to follow users or courses
Sold
206
Member since
2 year
Number of followers
28
Documents
7503
Last sold
13 hours ago
A+ Academic Resources provides high-quality exam materials, assignments, past papers, and verified study documents to help students achieve top grades with confidence. Our resources are carefully organized to support effective learning.

We have just re-established our shop, my aim is to elevate and guide students academically with actual guides and exams 100% verified.Incase you dont find the exam that you are looking for,feel free to inbox me and request any exam.My prices are never fixed,always negotiable , WELCOME ,LETS BEGIN.

3.6

30 reviews

5
12
4
5
3
6
2
2
1
5

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions