Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

Massachusetts Oil burner Practice Exam With Questions And Veried Answers Already Graded A 100 Percent Pass

Beoordeling
-
Verkocht
-
Pagina's
5
Cijfer
A+
Geüpload op
27-08-2024
Geschreven in
2024/2025

Massachusetts Oil burner Practice Exam With Questions And Veried Answers Already Graded A 100 Percent Pass The cross connection between two supply tanks shall not exceed? - ANSWER660 gallons When is an automatic draft control not required? - ANSWERWhen the equipment is designed to control the draft. Combustion performance testing can indicate: - ANSWERImproper air oil mixture, too much combustion air, and low pump pressure. If a second oil-burning appliance is installed in a single chimney, you must insure: - ANSWERSufficient draft is available for safe operation of all connected equipment. Delayed ignition can be caused by: - ANSWERWeak ignition transformer You should replace the oil burner nozzle with: - ANSWERThe manufacturers recommended nozzle spray pattern and spray angle. Viscosity problems can be corrected by: - ANSWERDecreasing the nozzle size and increasing the pump pressure accordingly The minimum operating pressure of an oil pump is: - ANSWER100 PSI If a stack relay fails you, must? - ANSWERReplace it with an approved type controller Aquastats are normally found on what type of heating systems? - ANSWERHydronic Airstats are found on what type of heating systems? - ANSWERForced warm air systems

Meer zien Lees minder
Instelling
Massachusetts Oil Burner Practice
Vak
Massachusetts Oil burner Practice

Voorbeeld van de inhoud

Massachusetts Oil burner Practice Exam With Questions And
Veried Answers Already Graded A 100 Percent Pass

The cross connection between two supply tanks shall not exceed? - ANSWER>>660 gallons


When is an automatic draft control not required? - ANSWER>>When the equipment is designed
to control the draft.


Combustion performance testing can indicate: - ANSWER>>Improper air oil mixture, too much
combustion air, and low pump pressure.


If a second oil-burning appliance is installed in a single chimney, you must insure: -
ANSWER>>Sufficient draft is available for safe operation of all connected equipment.


Delayed ignition can be caused by: - ANSWER>>Weak ignition transformer


You should replace the oil burner nozzle with: - ANSWER>>The manufacturers recommended
nozzle spray pattern and spray angle.


Viscosity problems can be corrected by: - ANSWER>>Decreasing the nozzle size and increasing
the pump pressure accordingly


The minimum operating pressure of an oil pump is: - ANSWER>>100 PSI


If a stack relay fails you, must? - ANSWER>>Replace it with an approved type controller


Aquastats are normally found on what type of heating systems? - ANSWER>>Hydronic


Airstats are found on what type of heating systems? - ANSWER>>Forced warm air systems

, Under sized returns on a warm air system can result in what? - ANSWER>>Short cycling of the oil
burner


Incorrect nozzle selection in regards to gallon per hour, can result in what problems in a steam
system? - ANSWER>>Some radiators not heating quickly enough


Low boiler water temperature in a hydronic hot water system may be caused by? -
ANSWER>>Undersized oil burner nozzles


Delayed opening oil valves are used to? - ANSWER>>Allow oil pump to come up to speed


If a steam boiler is to be installed with an automatic feeder it must also have: - ANSWER>>A
backflow prevention device


How can a damaged heat exchanger be detected on a forced warm air system? - ANSWER>>With
a smoke trace candle


If a high limit is installed to prevent high boiler water temperature, what is the function of the
low limit? - ANSWER>>To maintain temperature for domestic hot water


On a steam system, a plugged siphon loop can have what affect on the heating system? -
ANSWER>>Insufficient heat in the living space


On a triple acting aquastat a minimum of 20 degrees is recommend between the high and low
limit, this will prevent? - ANSWER>>The boiler going off on high limit before reaching the
minimum circulator temperature


An advantage of flame retention burner is - ANSWER>>Their high static pressure enables boilers
and furnaces with tighter more efficient heat exchange passages

Geschreven voor

Instelling
Massachusetts Oil burner Practice
Vak
Massachusetts Oil burner Practice

Documentinformatie

Geüpload op
27 augustus 2024
Aantal pagina's
5
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$15.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
winniewaweru Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
82
Lid sinds
2 jaar
Aantal volgers
36
Documenten
990
Laatst verkocht
2 maanden geleden
EXCELLENT HOMEWORK HELP AND TUTORING ,ALL KIND OF QUIZ AND EXAMS WITH GUARANTEE OF A

Am an expert on major courses especially; psychology,Nursing, Human resource Management and Mathemtics Assisting students with quality work is my first priority. I ensure scholarly standards in my documents and that's why i'm one of the BEST GOLD RATED TUTORS in STUVIA. I assure a GOOD GRADE if you will use my work.

4.9

61 beoordelingen

5
59
4
0
3
0
2
0
1
2

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen