Which is NOT a synonym for the preliminary/localizer image taken at the start of a CT examination? A. Topogram B. Scout C. Scanogram D. Spiral - Answer- D. Spiral The ability of a system to differentiate, on the image, objects with similar densities is known as: A. High contrast resolution B. Low contrast resolution C. Spatial resolution D. Temporal resolution - Answer- B. Low contrast resolution

Meer zien Lees minder
Instelling
Computed Tomography For Technologists 2nd Edition
Vak
Computed Tomography for Technologists 2nd Edition

Voorbeeld van de inhoud

Computed Tomography for Technologists 2nd Edition
Exam Review with questions and 100 %all sure answers
2024
Which is NOT a synonym for the preliminary/localizer image taken at the start of a CT examination?
A. Topogram
B. Scout
C. Scanogram
D. Spiral - Answer- D. Spiral


The ability of a system to differentiate, on the image, objects with similar densities is known as:
A. High contrast resolution
B. Low contrast resolution
C. Spatial resolution
D. Temporal resolution - Answer- B. Low contrast resolution


Each two dimensional square of data that make up the CT image is called a:
A. Pixel
B. Voxel
C. Matrix
D. Fragment - Answer- A. Pixel


How many pixels are contained in a 1,024 matrix image? A. 1,024
B. 2,048
C. 262,144
D. 1,048,576 - Answer- D. 1,048,576


Beam attenuation can be defined as:
A. The phenomenon by which artifacts result when lower energy photons are preferentially absorbed,
leaving only higher-intensity photons to strike the detector array.

,B. Xray energy that is produced from bombarding a substance with fast moving electrons.
C. The ability of the detector to capture transmitted photons and change them to electronic signals.
D. The phenomenon by which an xray beam passing through a structure is decreased in intensity or
amount because of absorption and interaction with matter. - Answer- D. The phenomenon by which an
xray beam passing through a structure is decreased in intensity or amount because of absorption and
interaction with matter.


CT basics - Answer- • Essentially an x-ray tube that rotates round the pt
• Table moves, feeding pt into the gantry
• Each large is data collected as a series of slices
o Each slice is divided into voxels (volume elements)


Multislice scanner - Answer- voxel thickness is equal to x-ray beam thickness


Slices - Answer- o Thinner slice higher radiation dose better quality image
o Width and height depend on FOV
o Determined by the operator
o Thickness is determined by the image requirements


calculate linear attenuation coefficient for each voxel - Answer- o From this a T # is calculated this
determines hoe the voxel appears
o Voxel appearance can be changed with windowing
♣ High CT numbers: brighter
♣ Low CT numbers: darker
• Linear attenuation coefficient is calculated in the reconstruction process


Linear attenuation coefficient calculation - Answer- Xray tube passes around the pt, through the pt and
detected when they leave the pt
o By comparing their intensities to unattenuated rays, the net linear attenuation is calculated for each ray
o This # is assigned to each voxel along the rays path
o By doing this from a number of different angles the true values for each voxel is obtained
• Each voxel is assigned a CT # which depends on its linear attenuation coefficient

,o This is assigned a shade of gray for the final display


Which of the following is a low attenuation structure:
A. Iodine filled aorta
B. Rib
C. Trachea
D. Calcified arteries - Answer- C. Trachea


An object is slightly less dense than water. What is the expected hounsfield measurement?
A. -940
B. -10
C. 50
D. 850 - Answer- B. -10


Why does the administration of iodinated contrast media result in an enhanced image?
A. Iodinated contrast material increases the ability of the enhanced structure to attenuate the xray beam.
B. Iodinated contrast material decreases the average photon energy of the xray beam; therefore more
photons are absorbed by the patient.
C. The administration of contrast material results in a smaller pixel, thereby increasing spatial resolution,
which results in an enhanced image.
D. - Answer- A. Iodinated contrast material increases the ability of the enhanced structure to attenuate the
xray beam.


The xray beam sources for CT produce xray energy that is polychromatic. This means:
A. When viewed by the naked eye, the beam exhibits many different colors.
B. It produce, as a byproduct, a substance known as polychlorinated biphenyl.
C. Photons contained in the beam are all of the same wavelength.
D. The beam comprises photons with varying energies. - Answer- D. The beam comprises photons with
varying energies.


An object that appears on the image but is not present in the object scanned is called a/n:

, A. Artifact
B. Anomaly
C. Shadow
D. Ghost - Answer- A. Artifact


first generation CT - Answer- Translate-Rotate
xray beam picked up by single detector and move together, then rotate together to image a different angle.
5min/slice


second generation CT - Answer- Translate-Rotate
xray beam picked up by a row of up to 30 detectors and move together, then rotate together to image a
different angle. 5-90s/slice


third generation CT - Answer- Rotate-Rotate
xray beam hits a row of detector wide enough to image a whole slice, then they both rotate together to
image a different angle. >1s/slice


fourth generation - Answer- Rotate-Rotate
fixed complete ring of detectors and xray source rotates around to capture a slice. they both move down
the patient to begin imaging a new slice


EBCT (electron beam computed tomography) - Answer- uses large electron gun as stay source, used in
cardiac imaging


Localizer scans (scout, topogram) - Answer- digital image acquisitions that are created while the tube is
stationary and the table moves through the scan field


conventional method (serial) - Answer- when the xray tube rotates around the patients, while the table
moves in increments per slice to generate the CT image.


Helical Method (spiral, volumetric) - Answer- xray tube and table move simultaneously. Tube rotates
around the patients as table is fed through the gantry

Geschreven voor

Instelling
Computed Tomography for Technologists 2nd Edition
Vak
Computed Tomography for Technologists 2nd Edition

Documentinformatie

Geüpload op
31 augustus 2024
Aantal pagina's
63
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$17.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Academicaffairs Kaplan University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
275
Lid sinds
3 jaar
Aantal volgers
221
Documenten
1385
Laatst verkocht
1 week geleden

3.9

36 beoordelingen

5
17
4
7
3
8
2
1
1
3

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen