1. If the EPA regulations should change after a technician becomes certified:
A. the technician certification is grandfathered for 6 months to allow time for
taking recertification exam
B. a new certification test must be taken within 90 days to be recertified
C. it is the technician's responsibility to comply with any future changes in the
law - Correct Answer C. it is the technician's responsibility to comply with
any future changes in the law
2. At high temperatures, (i.e., open flames, glowing metal surfaces, etc.) R-12 and
R-22 can decompose to form:
A. hydrazine gas
B. helium gas
C. phosgene gas
D. all of the above will be formed - Correct Answer C. phosgene gas
3. Which of the following refrigerants is most commonly used as a replacement for
R-12 in new household refrigerators?
A. R-123
B. R-24
C. R-141a/141b blend
D. R-134a - Correct Answer D. R-134a
4. Recovery equipment used for the service or repair of small appliances must be
certified by an EPA- approved laboratory if the recovery equipment was
manufactured after:
A. May 15, 1993
B. June 15, 1992
C. July 15, 1993
D. November 15, 1993 - Correct Answer D. November 15, 1993
5. What is the maximum allowable factory charge of refrigerant for type 1
appliances?
A. 4 pounds
B. 5 pounds
C. 7 pounds
, D. 10 pounds - Correct Answer B. 5 pounds
6. why is it important to obtain an accurate pressure reading of refrigerant inside a
recovery cylinder?
A. the pressure reading along with a temperature reading can indicate if
there is excessive air or other non-condensables in the cylinder
B. the pressure reading can indicate the remaining cylinder capacity
C. the pressure reading can indicate if the refrigerant has been damaged
D. both a and c - Correct Answer A- the pressure reading along with a
temperature reading can indicate if there is excessive air or other non-
condensables in the cylinder
7. Recovery devices that were manufactured after November 15, 1993 and are
used for recovery of refrigerant from small appliances must be capable of:
A. recovering 90% of the refrigerant when the compressor is operating or
achieving a 4 inch vacuum under the conditions of ARI 740-1993.
B. recovering 80% of the refrigerant when the compressor is operating
C. recovering 95% of the refrigerant when the compressor is operating or
achieving a 4 inch vacuum under the conditions of ARI740-1993
D. recovering 85% of the refrigerant when the compressor is operating -
Correct Answer A. recovering 90% of the refrigerant when the
compressor is operating or achieving a 4 inch vacuum under the
conditions of ARI 740-1993
8. Solderless piercing valves should not remain installed on refrigeration systems
after completion of repairs because:
A. they are too expensive to remain on every product
B. they tend to leak over time
C. they become loose and vibrate
D. both a and c - Correct Answer B. they tend to leak over time
9. when ever nitrogen is used to pressurize or blow debris out of the system:
A. only nitrogen vapor should be used
B. only liquid nitrogen should be used
C. either liquid or vapor nitrogen can be used