CSST BUILDING INSPECTION EXAM NEWEST ACTUAL
EXAM COMPLETE 120 QUESTIONS AND CORRECT
DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY
GRADED A+
Guards shall be required for open sided walking surfaces more than _
above the
floor or grade below. - ANSWER: 30in

Group M occupancy - ANSWER: MERCANTILE - Display and sale of merchandise

When required under concrete slabs, lap joints for polyethylene vapor retarders shall
not be less than - ANSWER: 6in

Audible alarm notification appliances shall provide a sound pressure level of.
decibels above the average ambient sound or _
_decibels above the maximum sound
level having a duration of at least 60 seconds, whichever is greater - ANSWER: 15 - 5

Particle board used as underlayment shall be at least ___ thick. - ANSWER: .25in

A bakery constructed of type IIIB construction, with an automated sprinkler
throughout shall not be more than ___ stories in height. - ANSWER: 3

What is the minimum nominal thickness of masonry chimney walls - ANSWER: 4 in

How far can a decorative trim project in to the required width of an exit pathway -
ANSWER: 1.5in

A 6 foot tall, 7-1/2 inch thick concrete wall with 5 feet of unbalanced backfill shall
have which of the following as minimum reinforcement? - ANSWER: Plain concrete

Work must commence on the site within_____after a permit is issued or it becomes
invalid. - ANSWER: 180 days

What is the minimum allowable thickness of a concrete floor slab, supported directly
on the ground? - ANSWER: 3.5 in

A mezzanine shall not exceed____
of the floor area of that room or space in which
they are located. - ANSWER: 1/3

Who is responsible for the maintenance of an existing building or structure? -
ANSWER: The owner or the owner,s agent

, The top of any exterior foundation shall extend above the elevation of the street
gutter at a point of discharge at least - ANSWER: 12 in

The maximum dimension permitted in the above image - ANSWER: 34 In

Combustible interior decorative trim, excluding handrails and guardrails, shall be
limited to a maximum of _ _of the aggregate wall or ceiling area in which it is located
- ANSWER: 10%

5.7 sq ft - ANSWER: emergency escape and rescue openings shall have a minimum
net clear opening of

1 hour - ANSWER: in an office building of type II construction, what is the minimum
required fire resistance rating of the interior baring wall

3 in - ANSWER: how far shall a 2 x 8 floor joist bare on an 8 inch CMU foundation wall

16 in - ANSWER: foundation walls of rough or rubblestone must be at least __ thick

2 hours - ANSWER: in a four story office building the elevator services the entire
building including the basement, what is the minimum fire resistance rating for the
machine room that is attached and services the elevator?

24 ft - ANSWER: what is the maximum amount of height of a solid roof sign
(measured from the roof surface)?

1 hour - ANSWER: where a fire barrier is utilized to separate a Group U occupancy
into multiple fire areas, what is the minimum fire resistance rating of the fire barrier?

1 in - ANSWER: a thermal barrier is not required form foam plastic installed in a
masonry or concrete wall, floor or roof system where the foam plastic insulation is
covered on each face by a minimum of ___ thickness of masonry or concrete

1 hour - ANSWER: what is the minimum fire protection rating for a fire door
assembly in a 1 hour rated exit enclosure

6 - ANSWER: the smoke level in a means of egress serving a smoke protected
assembly seating area is intended to be located a minimum of ___ feet above the
floor of the means of egress

8 ft - ANSWER: covered walkways implemented to protect the public during
construction shall have a clear height of not less than ____

30 in - ANSWER: A ___ minimum clear headroom in the attic space shall be provided
at or above the access opening

Connected book

Written for

Course

Document information

Uploaded on
September 17, 2024
Number of pages
6
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$18.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
maxmaxwellmm254 University College Maastricht
Follow You need to be logged in order to follow users or courses
Sold
9
Member since
1 year
Number of followers
1
Documents
839
Last sold
7 months ago
EXCELLENT HOMEWORK

EXCELLENT HOMEWORK HELP AND TUTORING ,ALL KIND OF QUIZ AND EXAMS WITH GUARANTEE OF A EXCELLENT HOMEWORK HELP AND TUTORING ,ALL KIND OF QUIZ AND EXAMS WITH GUARANTEE OF A Am an expert on major courses especially; psychology,Nursing, Human resource Management and Mathemtics Assisting students with quality work is my first priority. I ensure scholarly standards in my documents and that's why i'm one of the BEST GOLD RATED TUTORS in STUVIA. I assure a GOOD GRADE if you will use my work.

Read more Read less
4.9

135 reviews

5
123
4
11
3
0
2
0
1
1

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions