EPA 608 TYPE 1 ,TYPE 2 AND TYPE 3 LATEST ACTUAL EXAM
QUESTIONS AND CORRECT DETAILED ANSWERS
Technicians maintaining, servicing, repairing or disposing of high pressure or very
high-pressure appliances, except small appliances and MVAC, must be certified
either as a Universal Technician or a ______ ___. - ANSWER: Type 2

After the installation of any type of system, the unit should be pressurized with
_____ and _____ checked. - ANSWER: nitrogen leak

Nitrogen is an ______ gas. - ANSWER: inert

In order to determine the general area of a leak, technicians should use a _____ or
_____ leak detector. - ANSWER: electronic ultrasonic

After locating the general area of a leak, ______ ______ are used to pinpoint it. -
ANSWER: soap bubbles

A refrigeration unit using an open compressor that has not been used in several
months is likely to leak from the rotating shaft ______. - ANSWER: seal

During a visual inspection of any type of system, _____ of _____ are an indicator of a
refrigerant leak. - ANSWER: traces oil

Excessive ________, caused by a low refrigerant charge, is an indication of a leak in a
high-pressure system. - ANSWER: superheat

A low ______ _______ may be the cause of excessive superheat in a high-pressure
system. - ANSWER: refrigerant charge

Epa regulations require that all comfort cooling appliances containing more than
_____ lbs. of refrigerant MUST be repaired when the annual leak rate exceeds _____
%. - ANSWER: 50 15

Epa regulations require that all commercial and industrial process refrigeration
systems containing more than _____ lbs. of refrigerant MUST be repaired when the
annual leak rate exceeds _____ %. - ANSWER: 50 35

Recovered refrigerants may contain _____, moisture, and oil. - ANSWER: acids

Recovered refrigerants may contain acids, ______, and oil. - ANSWER: moisture

Recovered refrigerants may contain acids, moisture, and ________. - ANSWER: oil

, Because of the acids, moisture, and oil that may be in recovered refrigerants, it is
necessary to frequently check and change both the _____ and _____ on recycling
machines. - ANSWER: oil filter

Recycling and Recovery machines using ______ compressors may overheat when
pulling a deep vacuum. - ANSWER: hermetic

Recycling and Recovery machines using hermetic compressors may overheat when
pulling a deep vacuum because the unit relies on the flow of ______ through the
compressor for ______. - ANSWER: refrigerant cooling

Before using a recovery unit, you should always check the _______ _______
_______, the oil level of the unit, and evacuate and recover any remaining
refrigerant in the unit's receiver. - ANSWER: service valve positions

Before using a recovery unit, you should always check the service valve positions, the
_____ _____ of the unit, and evacuate and recover an remaining refrigerant in the
unit's receiver. - ANSWER: oil level

Before using a recovery unit, you should always check the service valve positions, the
oil level of the unit and evacuate and recover an remaining refrigerant in the unit's
________. - ANSWER: receiver

Technicians working with multiple refrigerants, before recovering and/or recycling a
different refrigerant, must ______ the recover/recycle equipment by recovering as
much of the first refrigerant as possible, change the filter, and evacuate. Exception:
technicians working with R - 134 A. - ANSWER: purge

Technicians working with multiple refrigerants, before recovering and/or recycling a
different refrigerant, must purge the recover/recycle equipment by ______ as much
of the first refrigerant as possible, change the filter, and evacuate. Exception:
technicians working with R - 134 A. - ANSWER: recovering

Technicians working with multiple refrigerants, before recovering and/or recycling a
different refrigerant, must purge the recover/recycle equipment by recovering as
much of the first refrigerant as possible, change the ______, and evacuate.
Exception: technicians working with R - 134 A. - ANSWER: filter

Technicians working with multiple refrigerants, before recovering and/or recycling a
different refrigerant, must purge the recover/recycle equipment by recovering as
much of the first refrigerant as possible, change the filter, and ______. Exception:
technicians working with R - 134 A. - ANSWER: evacuate

Technicians working with multiple refrigerants, before recovering and/or recycling a
different refrigerant, must purge the recover/recycle equipment by recovering as
much of the first refrigerant as possible, change the filter, and evacuate. Exception:
technicians working with ______. - ANSWER: 134

Connected book

Written for

Course

Document information

Uploaded on
September 25, 2024
Number of pages
8
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$18.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
tutorsection1 Chamberlain College Of Nursing
Follow You need to be logged in order to follow users or courses
Sold
49
Member since
1 year
Number of followers
8
Documents
1079
Last sold
3 days ago

4.9

459 reviews

5
418
4
31
3
7
2
1
1
2

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions