Connectors shall connect to a chimney flue at a point not less than ______ above the lowest portion of the interior of the chimney flue: a: 10 inches b: 12 inches c: 16 inches d: 14 inches - ANSWERb: 12 inches Refer: IMC Code 801.12

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

KY HVAC JOURNEYMAN EXAM 2024 NEWEST
100 QUESTIONS AND DETAILED ANSWERS
ALREADY GRADED A+.NEW!!!

Liquid adhesive coatings used on air filters for air conditioning or heating systems shall have a
flash point not lower than _______ :
a: 200°F
b: 250°F
c: 350°F
d: 325°F - ANSWER>>d: 325°F
Refer: IMC Code 605.1

Connectors shall connect to a chimney flue at a point not less than ______ above the lowest
portion of the interior of the chimney flue:
a: 10 inches
b: 12 inches
c: 16 inches
d: 14 inches - ANSWER>>b: 12 inches
Refer: IMC Code 801.12

Liquids having flash points at or above 100°F (38°C) and below 140°F (60°C) comes under
________ combustible liquid:
a: Class I
b: Class II
c: Class IIIA
d: Class IIIB - ANSWER>>b: Class II

Where located adjacent to walkways, the vertical termination of mechanical draft systems shall
be not less than ______ above the level of the walkway:
a: 7 feet
b: 5 feet
c: 3 feet
d: 4 feet - ANSWER>>a: 7 feet
Refer: IMC Code 804.3.5.1

,Commercial kitchen Grease duct systems serving a Type I hood shall be designed and installed
to provide an air velocity within the duct system of not less than ______ feet per minute:
a: 1000
b: 500
c: 400
d: 250 - ANSWER>>b: 500
Refer: IMC Code 506.3.4

The minimum openable area to the outdoors shall be ____ of the floor area being naturally
ventilated:
a: 6%
b: 8%
c: 4%
d: 2% - ANSWER>>c: 4%
Refer: IMC Code 504.7

Fire dampers are not required at penetrations of shafts where the steel exhaust subducts
extend at least _______ vertically in exhaust shafts provided that there is a continuous airflow
upward to the outdoors:
a: 25 inches
b: 22 inches
c: 32 inches
d: 28 inches - ANSWER>>b: 22 inches
Refer: IMC Code 607.5.5 Exp 1.1

Underground Ducts shall have a minimum slope of _______ per foot to allow drainage to a
point provided with access:
a: 1/2 inch
b: 1/6 inch
c: 1/4 inch
d: 1/8 inch - ANSWER>>d: 1/8 inch
Refer: IMC Code 603.8.1

Masonry chimney flues shall be provided with a cleanout opening having a minimum height of
______ :
a: 6 inches
b: 12 inches
c: 8 inches

, d: 10 inches - ANSWER>>a: 6 inches
Refer: IMC Code 801.13

Commercial Kitchen Exhaust equipment serving a Type I hood shall have a clearance to
combustible construction of not less than ______ :
a: 30 inches
b: 12 inches
c: 24 inches
d: 18 inches - ANSWER>>d: 18 inches
Refer: IMC Code 506.5.4

Steam-Heating Boiler operated at pressures not exceeding ______ for steam:
a: 20 psi
b: 15 psi
c: 10 psi
d: 25 psi - ANSWER>>b: 15 psi
Refer: IMC Code - Definitions

Commercial cloth dryer ducts shall have a minimum clearance of _____ to combustible
materials:
a: 9 inches
b: 12 inches
c: 8 inches
d: 6 inches - ANSWER>>d: 6 inches
Refer: IMC Code 504.7

The vent horizontal termination point for a mechanical draft system shall not be located closer
than _____ to an interior corner formed by two walls perpendicular to each other.
a: 5 feet
b: 6 feet
c: 4 feet
d: 3 feet - ANSWER>>d: 3 feet
Refer: IMC Code 804.3.4.4

Breathing Zone region shall be more than _______ from the walls of the space or from fixed air-
conditioning equipment:
a: 3 feet
b: 1.5 feet

Geschreven voor

Vak

Documentinformatie

Geüpload op
10 oktober 2024
Aantal pagina's
17
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$19.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
Profcharleswellington
5.0
(1)

Maak kennis met de verkoper

Seller avatar
Profcharleswellington Princeton university
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
5
Lid sinds
2 jaar
Aantal volgers
0
Documenten
1316
Laatst verkocht
4 maanden geleden
Stuvia online

Stuvia study material for exel in academics

5.0

1 beoordelingen

5
1
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen