Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

CALIFORNIA UST SERVICE TECHNICIAN PART 1 EXAM ACTUAL EXAM QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES|AGRAD

Beoordeling
-
Verkocht
-
Pagina's
5
Cijfer
A+
Geüpload op
11-10-2024
Geschreven in
2024/2025

CALIFORNIA UST SERVICE TECHNICIAN PART 1 EXAM ACTUAL EXAM QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES|AGRAD

Instelling
Vak

Voorbeeld van de inhoud

CALIFORNIA UST SERVICE TECHNICIAN PART 1 EXAM
ACTUAL EXAM QUESTIONS AND CORRECT DETAILED
ANSWERS WITH RATIONALES|AGRAD
July 1 2005, service techs shall possess or work under someone who has a current
certification indicating he or she has passed the ? - ANSWER: California UST service
technician exam

ICC cert must be renewed every? - ANSWER: 24 months

Service techs must posses or be employed by a person who has the appropriate
contractors license unless? - ANSWER: The individual has a Tank testing licens

Service tech is defined by any individual who? - ANSWER: Test UST monitoring
equipment
Trouble shoots UST systems
Installs UST monitoring equipment

If the manufacturer training no longer exist , the local angency may? - ANSWER:
Approve comparable alternat training .

UST includes? - ANSWER: Tank and connected piping

What is considered and UST - ANSWER: petroleum storage tank

What UST system meets the requirements for secondary containment? - ANSWER:
Doubled wall tanks

According to title 23; the following piping components if installed after July 1 1987
must have secondary containment - ANSWER: Pressured product piping

Considered "pipe" on tanks installed after July 1 2003 - ANSWER: Pressured product
piping and below ground vapor recovery

Under dispenser containment (UDC) was required for all UST systems by - ANSWER:
December 31 2003

System for exchanging gas vapors in a storage tank and product in a fuel delivery
truck - ANSWER: Stage 1 vapor recovery

An approved method for non visual monitoring for existing UST systems. - ANSWER:
Statistical Inventory Reconciliation (SIR)

ATG must be capable for detecting a release of ? - ANSWER: .2 gallons per hour

, Manual inventory reconciliation. - ANSWER: No longer an approved method for non
visual monitoring on existing UST systems

Automatic line leak detectors installed on underground piping with secondary
containment shall be capable of tetecting a leak of ? - ANSWER: 3 gallons per hour at
10 psi

ATG should be programmed to test the tank ? - ANSWER: At least monthly

According to PEI RP 300 a combustible gas can be used to ? - ANSWER: Detect vapor
leaks in a vapor recovery system.

According to PEI RP 300. A written scope of work for vapor recovery installation
should include? - ANSWER: Construction plans

Positive shut off overfill protection device must stop the flow of fuel when the tank is
no more then ? - ANSWER: 95% full

According to EO VR 201 A What could cause a nozzle shut off mechanism or
malfunction? - ANSWER: Depended filter seal damage

According to VR 201 A Breakaway reconnection must be ? - ANSWER: Logged in GDF
log

According to PEI RP 300 the following method of documenting piping location is NOT
to ? - ANSWER: Sketch a diagram on the inside cover of vapor recovery equipment
manual

According to PEI RP 300 as built drawing or pictures of the underground pipping and
other components shall be ? - ANSWER: Maintained as long as UST is in service

According to EO VR 101 E maintance records are required to include? - ANSWER:
Name and designated UST operator .

The Phil-Tite EVR phase 1 system require that vapor vent pipes at any UST system be
- ANSWER: Used with no more then 3 p/v valves

According to EO VR 2010 after installing a new spout assembly in the Healy 900
nozzle the following test must be conducted ? - ANSWER: Nozzle dispensing shut off
test

According to Healy EO VR 201 A a vapor recovery record are to be maintained by? -
ANSWER: Gasoline dispensing facility operator
(GDF)

how many feet within a public drinking well require an enhanced leak detection test
- ANSWER: 1000 feet

Gekoppeld boek

Geschreven voor

Vak

Documentinformatie

Geüpload op
11 oktober 2024
Aantal pagina's
5
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$18.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
morrismuriithi009
3.0
(1)

Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
morrismuriithi009 Teachme2-tutor
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
1
Lid sinds
1 jaar
Aantal volgers
0
Documenten
760
Laatst verkocht
6 maanden geleden

3.0

1 beoordelingen

5
0
4
0
3
1
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen