California Fluoroscopy State Board Exam
Questions and Answers- Updated 2024
What digital fluoroscopic imaging technique utilizes changing masks, which provides
information of changes in contrast media content within a structure
1.Time interval difference imaging
2. Mask mode fluoroscopy
3. K -edge fluoroscopy
4. Synchronized fluoroscopy - Answer✔✔-1. Time interval difference imaging
All of the following will directly influence the table-top exposure rate except
1. Light in the fluoroscopy room
2. kVp
3. Target to panel distance
4. Filtration - Answer✔✔-1. Light in the fluoroscopy room
Attenuation of a radiation beam's intensity as it passes through an absorber is governed by
1. Time
2. The specific mediums density
Page 1/141
,EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024
3. The energy of the radiation
4. The thickness of the absorber traversed - Answer✔✔-2. The specific mediums density
3. The energy or radiation
4. The thickness of the absorber traversed
What recording medium will result in the least recorded resolution
1. Spot films using a spot film camera
2. video tape recording
3. spot films using conventional cassettes
4. video disc recording - Answer✔✔-2. video tape recording
During the period when an individual receives an occupational dose, they are _ considered to
be a "member of the public"
1. sometimes
2. always
3. it depends
4. never - Answer✔✔-4.never
A person wearing a _ apron will reduce transmitted exposure to approximately 99.9% of the
incident scatter dose
1. 1.5 mm Pb equivalent
Page 2/141
,EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024
2. 0.50 mm Pb equivalent
3. 0.25 mm Pb equivalent
4. 1.0 mm Pb equivalent - Answer✔✔-2. 0.50 mm Pb equivalent
If the input phosphor of an image intensifier measures 15 inches in diameter and the output
phosphor measures 1.0 inches, the minification gain would be
1. 30
2. 225
3. 175
4. 300 - Answer✔✔-Minification Gain = {15(2) = 225} input screen diameter (2) / {1.0 (2) = 1}
output screen diameter (2) = 225/1= 225
What electronic system is designed to help maintain a consistent level of image brightness
1. photo-emitter
2. automatic brightness stabilizer
3. camera control unit
4. vidicon - Answer✔✔-2. automatic brightness stabilizer
Energy subtraction as used in digital fluoroscopy exhibits less _ than temporal subtraction
1. complexity
2. x-ray intensity
Page 3/141
, EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024
3. kVp
4. motion artifact - Answer✔✔-4. motion artifact
Bone marrow dose is measured
1. directly from bone marrow
2. as estimate from gonadal dose
3. as an estimate from ESE
4. directly from the beam - Answer✔✔-3. as an estimate from the ESE
The Privacy Rule is meant to ensure that there is/are
1. security of electronic personal health information
2. standardization of electronic patient health data
3. limits PHI to a "need to know.." basis to carry out medical treatment
4. all the listed answers - Answer✔✔-4. all the listed answers
To provide illumination stability of the virtual image during fluoroscopy, most modern units will
automatically adjust radiation levels for more dense and more radiolucent body parts. This
functionality is known as:
1. velling glare
2. image flare
3. automatic adaption