NATE Exam: Air Conditioning and Heat Pumps/ 95 Q&A/ . Terms like: Which of the following factors affects a customer's level of comfort? a. Air movement b. Humidity c. Temperature d. All of the above - Answer: d (All of the above: air movement, humidity, temperature) A cooling load calculation estimates the sensible heat gain of a structure. The maximum sensible capacity of a cooling-only system should be within ____% of this calculated value. a. ±10% b. +10% c. +15% d. +30% - Answer: c (+15%) The maximum sensible cooling capacity of a heat pump should be within ____% of the calculated sensible heat gain of a structure with a large heating load. a. ±10% b. +15% c. -25% d. +25% - Answer: d (+25%)

Show more Read less
Institution
NATE
Course
NATE

Content preview

NATE Exam: Air Conditioning and Heat Pumps/
95 Q&A/ 2024-2025.
Which of the following factors affects a customer's level of comfort?


a. Air movement
b. Humidity
c. Temperature
d. All of the above - Answer: d (All of the above: air movement, humidity,
temperature)


A cooling load calculation estimates the sensible heat gain of a structure. The
maximum sensible capacity of a cooling-only system should be within ____% of
this calculated value.


a. ±10%
b. +10%
Page 1 of 35

,c. +15%
d. +30% - Answer: c (+15%)


The maximum sensible cooling capacity of a heat pump should be within ____% of
the calculated sensible heat gain of a structure with a large heating load.


a. ±10%
b. +15%
c. -25%
d. +25% - Answer: d (+25%)


The combined output of a heat pump and its auxiliary heat should not exceed the
calculated heat loss of a home by more than ____%.


a. 10%
b. 15%
c. 20%
d. 25% - Answer: b (15%)


What amount of auxiliary electric heat is needed when the output of a heat pump
on a design day equals 18,800 Btuh and the heat loss of a home is 29,700 Btuh?


a. 2.1 kWh
b. 3.2 kWh
c. 5.0 kWh

Page 2 of 35

,d. 10.9 kWh


Note: 3,413 Btu/kW - Answer: b (3.2 kWh)


The three processes that transfer heat energy are conduction, convection, and
____.


a. concentration
b. radiation
c. refraction
d. static pressure - Answer: b (radiation)


Heat transfer that occurs when substances of different temperatures are in
contact with each other is called ____.


a. concentration
b. conduction
c. convection
d. radiation - Answer: b (conduction)


What effect does raising the pressure in a sealed system have on refrigerant?


a. It becomes more difficult to subcool the liquid refrigerant
b. It becomes more difficult to superheat the refrigerant vapor
c. The refrigerant's boiling point decreases

Page 3 of 35

, d. The refrigerant's boiling point increases - Answer: d (The refrigerant's boiling
point increases)


What is the primary danger to people near an accidental refrigerant release or
spill?


a. Blurred vision caused by the refrigerant vapor coming in contact with the eyes
b. Changes in weather patterns caused by global warming
c. Damage to the food chain caused by decreased ozone levels in the stratosphere
d. Suffocation caused by the heavier refrigerant displacing oxygen in the air -
Answer: d (Suffocation caused by the heavier refrigerant displacing oxygen in the
air)


The maximum temperature at which refrigerant may be stored is ____°F when the
container is no more than ____% full of liquid by volume.


a. 120°F, 60%
b. 125°F, 60%
c. 125°F, 80%
d. 135°F, 80% - Answer: c (125°F, 80%)


Boiling of the refrigerant occurs in which system component?


a. Compressor
b. Condenser

Page 4 of 35

Written for

Institution
NATE
Course
NATE

Document information

Uploaded on
October 20, 2024
Number of pages
35
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$10.89
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF


Also available in package deal

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Pronurse1 Alabama State University
Follow You need to be logged in order to follow users or courses
Sold
2527
Member since
2 year
Number of followers
64
Documents
3433
Last sold
3 months ago
passionate tutor

I am passionate and reliable in my work as a tutor, for all your assignments and questions on Various subjects, please don't hesitate to reach out to me. May you Prosper in your field of studies.

4.2

601 reviews

5
313
4
164
3
89
2
24
1
11

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions