ACTUAL EXAM COMPLETE 150 QUESTIONS AND
CORRECT DETAILED ANSWERS (VERIFIED
ANSWERS) |ALREADY GRADED A+
A Crane hooks throat open must not exceed -
✔✔ANSW✔✔..15% of its original size OSHA
1910.180(d)(3)(v)
A velocity readout shall be provided - ✔✔ANSW✔✔..At the
operators station
According to a metric conversion table bars multiplied by
14.50377377 equals - ✔✔ANSW✔✔..pounds per square inch
According to ASMA 30.3, load hoist rotation resistant wire rope
has a design factor of - ✔✔ANSW✔✔..5 to 1 ASME 3-1.5.5(b)
According to ASMA B30.3, on whose recommendations should
a preventative maintenance program be set up -
✔✔ANSW✔✔..Crane manufacturer ASME 3-2.3.1(a)
According to ASME B30.3 a class __________ Fire
extinguisher shall be kept in the cab or on the machinery
platform - ✔✔ANSW✔✔..10BC
,According to ASME B30.3 a crane should be plumbed to -
✔✔ANSW✔✔..1 to 500 ASME 3-1.1.5(g)
According to ASMe B30.3 a frequent inspection in heavy
service conditions must be performed - ✔✔ANSW✔✔..daily to
weekly
According to ASME B30.3 a frequent inspection in light service
conditions must be performed - ✔✔ANSW✔✔..monthly
According to ASME B30.3 a frequent inspection in normal
service conditions must be performed - ✔✔ANSW✔✔..weekly
to monthly
According to ASME B30.3 a frequent inspection shall be
performed by a/an - ✔✔ANSW✔✔..Designated Person
According to ASME B30.3 A Periodic inspection in heavy
service conditions must be performed - ✔✔ANSW✔✔..Qarterly
According to ASME B30.3 a periodic inspection in light service
conditions must be performed - ✔✔ANSW✔✔..annually
According to ASME B30.3 a periodic inspection in normal
service conditions must be performed - ✔✔ANSW✔✔..Semi-
annually to annually
, According to ASME B30.3 a periodic inspection of a tower
cranes wire rope shall be performed at least? -
✔✔ANSW✔✔..Annually ASME 3-2.4.2(b)(1)
According to ASME B30.3 a periodic inspection shall be
performed by a/an - ✔✔ANSW✔✔..Appointed person
According to ASME B30.3 all controls shall be tested by the
operator - ✔✔ANSW✔✔..At the start of a new shift
According to ASME B30.3 an overhead power line is always
considered to be - ✔✔ANSW✔✔..Energized until the power
company had verified it is not energized
According to ASME B30.3 an overhead power line is ALWAYS
considered to be - ✔✔ANSW✔✔..Energized until the power
company has verified it is not energized
According to ASME B30.3 and OSHA you should always have
at least how many. wraps on a hoist drum - ✔✔ANSW✔✔..2
ASME 3-3.2.1(d)(7)
According to ASME B30.3 hoist rope should be visually
inspected at least once each - ✔✔ANSW✔✔..work day
According to ASME B30.3 if any controls do not operate
properly they shall be adjusted or repaired prior to -
✔✔ANSW✔✔..Commencing the next lift operation