Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

NICET LEVEL 1 EXAM 2024 ACTUAL EXAM COMPLETE 400 QUESTIONS WITH DETAILED VERIFIED ANSWERS (100% CORRECT ANSWERS) /ALREADY GRADED A+

Rating
-
Sold
-
Pages
7
Grade
A+
Uploaded on
28-10-2024
Written in
2024/2025

NICET LEVEL 1 EXAM 2024 ACTUAL EXAM COMPLETE 400 QUESTIONS WITH DETAILED VERIFIED ANSWERS (100% CORRECT ANSWERS) /ALREADY GRADED A+

Institution
Course

Content preview

NICET LEVEL 1 EXAM 2024 ACTUAL EXAM COMPLETE 400
QUESTIONS WITH DETAILED VERIFIED ANSWERS (100%
CORRECT ANSWERS) /ALREADY GRADED A+
Fire Alarm Code? - ANSWER: NFPA 72

National Electric Code? - ANSWER: NFPA 70

AHJ? - ANSWER: Authority Having Jurisdiction

Disconnecting means for fire alarm power shall be what color? - ANSWER: Red

If a combination audible visible appliance is installed, the location of the installed
appliance shall be determined by the requirements of... - ANSWER: The visible
appliance

Two resistors are connected in parallel. Resister one measures 300 ohms and resistor
two measures 300 ohms. What is their equivalent resistance? - ANSWER: 150 ohms

Fire warning equipment to be installed in residential occupancies shall produce the
audible emergency evacuation signal described in... - ANSWER: ANSI S3.41

The minimum number of restorable fixed temperature spot type heat detectors that
must be tested during each annual test is... - ANSWER: Two detectors or more on
each initiating devices circuit

What is the color code requirement for a spot type heat detector rated at 200°F? -
ANSWER: White

Unless otherwise recommended by the manufacturer's published instructions, single
and multiple station smoke alarms installed in one and two family dwellings shall be
replaced every... - ANSWER: 10 years from the date of manufacture

When testing a water level supervisory switch serving a pressure tank, a signal shall
indicate if the water level has changed from the required level by... - ANSWER: Rising
or falling 3 inches

Fire alarm cables are permitted to be strapped to conduit to support the cable. -
ANSWER: False

Where non-powered limited wiring is installed exposed, it must be mechanically
protected within how many feet of the finished floor? - ANSWER: 7 feet

According to NFPA 72 visible notification appliances for non-sleeping areas must be
mounted between — and — inches above the finished floor? - ANSWER: 80 & 96

, If system impairment occurs, the owner must be notified — and within —? -
ANSWER: In writing & 24 hours

Conductors returning to the fire alarm control panel from the last field device on the
circuit might indicate what type of circuit? - ANSWER: Class A

Secondary power supplies for an EVAC fire alarm system shall be capable of
operating for a minimum of — of standby followed by — of alarm. - ANSWER: 24
hours and 15 minutes

The secondary power supply for protected premises shall automatically provide
power within how many seconds when the primary power fails? - ANSWER: 10
seconds

When the temperature exceeds how many degrees Fahrenheit should spot type
smoke detectors not be installed? - ANSWER: Above 100°F

Who is responsible for maintaining personal protective equipment? - ANSWER: The
employee

What does GFCI stand for? - ANSWER: Ground fault circuit interrupter

After initial installation, a fixed temperature non-restorable spot type heat detector
shall be tested after how many years? - ANSWER: 15

Heat detectors should be selected to operate at least how many degrees Fahrenheit
above the maximum expected ambient temperature at the ceiling of the protected
space? - ANSWER: 20°F

According to NFPA 72, testing records of the fire alarm system shall be kept until the
next test and... - ANSWER: Every one year after

Who is responsible for storing and maintaining test records for the fire alarm
system? - ANSWER: Owner of the system

Household fire alarm system smoke detectors shall be tested by a technician how
regularly? - ANSWER: Annually

Inspection, testing, or maintenance of the fire alarm system shall be permitted to be
done by the building owner or another organization other than the building owner
if... - ANSWER: Work is conducted under a written contract

The handle of a manual pull station initiating devices shall be mounted not less than
— and not more than — above the finish floor? - ANSWER: 42 & 48

Connected book

Written for

Course

Document information

Uploaded on
October 28, 2024
Number of pages
7
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$18.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
charitywairimuuu Teachme2-tutor
Follow You need to be logged in order to follow users or courses
Sold
18
Member since
1 year
Number of followers
2
Documents
1295
Last sold
6 months ago
EXCELLENT HOMEWORK HELP AND TUTORING ,

EXCELLENT HOMEWORK HELP AND TUTORING ,ALL KIND OF QUIZ AND EXAMS WITH GUARANTEE OF A EXCELLENT HOMEWORK HELP AND TUTORING ,ALL KIND OF QUIZ AND EXAMS WITH GUARANTEE OF A Am an expert on major courses especially; psychology,Nursing, Human resource Management and Mathemtics Assisting students with quality work is my first priority. I ensure scholarly standards in my documents and that\'s why i\'m one of the BEST GOLD RATED TUTORS in STUVIA. I assure a GOOD GRADE if you will use my work.

Read more Read less
4.6

545 reviews

5
409
4
81
3
30
2
18
1
7

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions