Electrician's Licensing Exam (Common Electrician's
Licensing Exam Questions) with Answers


NEC Article ______ defines breakers and fuses. - ANSWER According to NEC
Article 100, a device that opens and closes a circuit by nonautomatic means
automatically closes for a predetermined overcurrent.

Annex _____ of NEC covers conduit fill. - ANSWER Annex C of NEC covers conduit
and tubing fill for conductors and fixture wire fill.

NEMA stands for National Electrical Manufacturers Association - ANSWER True -
NEMA is the acronym for National Electrical Manufacturers Association.

Which NEC tables(s) cover(s) the fill of metal boxes? - ANSWER The fill of metal
boxes appears in NEC Tables 314.6 A and B.

What NEC table would you go to to find trade size of conduit and raceway size? -
ANSWER Chapter 9, Table 4 outlines trade size of conduit as well as raceway size.

The smaller kitchen counter requiring a receptacle is _____ inches. - ANSWER A
12in. counter requires a receptacle because it holds small appliances.

A 12-foot hallway requires one receptacle to meet code. (True or False) - ANSWER
True, One is required, Two are suggested.

NEC Article 100 is dedicated to? - ANSWER Definitions

NEC section 250.28A provides information on what material can be used for a main
bonding jumper. (True or False) - ANSWER True

A bonding screw is what color? - ANSWER A bonding screw is green.

A subpanel requires a main bonding screw? (True or False) - ANSWER False, A
main bonding screw is unneeded in a subpanel.

NEC Table _____ covers grounding electrode conductor sizing. - ANSWER NEC
Table 250.66

Define a grounding system according to NEC. - ANSWER A gounding system is
connected to the ground or to a conductive body that extends the ground connection.

What is the topic of NEC Section 250.122? - ANSWER Is dedicated to the sizes of
the equipment grounding conductor

What is the NEC definition of a circuit breaker? - ANSWER A device designed to trip
when an overcurrent is detected.

, What is the subject of NEC Section 250-2D? - ANSWER Bonding jumpers

______ is the subject of NEC Section 680.20. - ANSWER Electrical installations at
permanently installed pools.

Which NEC Section covers types of equipment grounding conductors. - ANSWER
NEC Section 250.118

Which NEC sections covers identification of equipment grounding conductors? -
ANSWER NEC Section 250.119

Which NEC Section covers ground terminal identification on wiring devices? -
ANSWER NEC Section 250.126

True or False.
The definition of bonded is: the connection between the grounded circuit conductor
and the equipment grounding conductor, or the supply side bonding jumper, or both,
at the service. - ANSWER False. Article 100

NEC Section 250.142 provides information on what topic? - ANSWER Use of
Grounded circuit conductor for grounding equipment.

NEC Section Table 300.5 states that the minimum cover required for a direct burial
cable is _______ inches - ANSWER 24 inches.

Which NEC article covers cable trays? - ANSWER NEC Article 392

Threaded pipe can be used for bonding purposes? (True or False) - ANSWER True
(NEC 250.92B)

Shoulder fittings with locknuts are allowable as bonding devices? (True or False) -
ANSWER True (NEC 250.92B)

What kind of information does NEC Section 250.66 cover? - ANSWER Covers the
sizes of alternating current grounding electrode conductors.

Which NEC article covers service drops? - ANSWER NEC Article 230

According to NEC, trees are approved to support service conductors. (True or False)
- ANSWER False, NEC does not allow vegetation to support service conductors.

Above sidewalks accessible by pedestrians, a service drop not over 600V must be at
least _____ft. high. - ANSWER 10ft.

What is the service drop height, in feet, of a 200-amp service crossing residential
property? - ANSWER 12ft.

The required clearance for a 400-amp service drop across a major roadway is? -
ANSWER 18ft.

Geschreven voor

Vak

Documentinformatie

Geüpload op
28 oktober 2024
Aantal pagina's
6
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$18.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
tutorsection1 Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
49
Lid sinds
1 jaar
Aantal volgers
8
Documenten
1079
Laatst verkocht
3 dagen geleden

4.9

459 beoordelingen

5
418
4
31
3
7
2
1
1
2

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen