Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

NICET Inspect & Test LVL 2 Exam Questions And Well Elaborated Solutions

Beoordeling
-
Verkocht
-
Pagina's
5
Cijfer
A+
Geüpload op
30-10-2024
Geschreven in
2024/2025

NICET Inspect & Test LVL 2 Exam Questions And Well Elaborated Solutions Consider a smoke control system with a stairwell pressurization system. A _____ shall be provided in the air supply to the pressurized stairwell. A. Supervisory switch to monitor fan operation B. Manual fire alarm box C. Heat detector D. Smoke detector - answer -D. Smoke Detector NFPA 92 - 6.4.6.2.1 NFPA 72 states that smoke detector spacing shall be reduced where the airflow in a defined space exceeds _____ air changes per hour? A. 6 B. 7 C. 6.5 D. 7.5 - answer -D. 7.5 NFPA 72 17.7.6.3.3.1 Which of the following requires a visual inspection frequency of quarterly? (Select Two) A. Waterflow devices B. Radiant energy detectors C. Smoke detectors D. Visible notification appliances - answer -A. Waterflow devices B. Radiant energy detectors NFPA 72 Table 14.3.1 A project in an unsprinklered facility is using CI (circuit integrity) cable to provide a 2-hour fire rated resistance for a circuit. What is the pathway survivability rating? A. Level 1 B. Level 2 C. Level 3 D. Level 4 - answer -B. Level 2 NFPA 72 12.4.3 Consider communications methods for supervising station fire alarm systems. A communication technology which requires annunciation at the supervising station for degradation of the communications channel not to exceed 90 seconds from the time of actual failure is _____? A. Two way radio multiplex systems B. Performance based technology C. DACT systems D. One way private radio systems - answer -A. Two way radio multiplex systems NFPA 72 Table A.26.6.1 Consider an area where the temperature is 120 degrees Fahrenheit. The most appropriate type of smoke detector for this environment is _____? A. Smoke detectors are not appropriate B. Projected beam C. Photoelectric D. Ionization - answer -A. Smoke detectors are not appropriate NFPA 72 A.17.7.1.8 When testing an FSCS, which of the following modes are required to be tested? (Select Two) A. Manual override of normal mode B. Manual override of automatic mode C. Automatic override of normal mode D. Automatic override of alarm mode - answer -A. Manual override of normal mode B. Manual override of automatic mode NFPA 92 - 8.4.7.2 According to NFPA 72, cellular transmission is a performance based technology and as such _____? A. Requires AHJ approval B. Requires the use of a DACT C. Requires a secondary means of transmission D. Does not require a secondary communications path - answer -D. Does not require a secondary communications path NFPA 72 26.6.3.3 Consider the installation of a protected premises fire alarm system. All software and firmware shall be protected against unauthorized access. Access by persons who have are trained and authorized to either repair the control unit or to alter its site specific data or operating system program, thereby changing its basic mode of operation should be considered Access Level _____? A. 4 B. 1 C. 2 D. 3 - answer -A. 4 NFPA 72 A.23.2.2.2 Consider the use of spot type smoke detectors at elevations above 3,000 feet above sea level. This altitude may affect _____ detectors? A. Projected beam B. Photoelectric C. Air sampling D. Ionization - answer -D. Ionization

Meer zien Lees minder
Instelling
NICET Inspect
Vak
NICET Inspect

Voorbeeld van de inhoud

NICET Inspect & Test LVL 2 Exam Questions
And Well Elaborated Solutions

Consider a smoke control system with a stairwell pressurization system. A _____
shall be provided in the air supply to the pressurized stairwell.

A. Supervisory switch to monitor fan operation
B. Manual fire alarm box
C. Heat detector
D. Smoke detector - answer -D. Smoke Detector
NFPA 92 - 6.4.6.2.1

NFPA 72 states that smoke detector spacing shall be reduced where the airflow in
a defined space exceeds _____ air changes per hour?

A. 6
B. 7
C. 6.5
D. 7.5 - answer -D. 7.5
NFPA 72 17.7.6.3.3.1

Which of the following requires a visual inspection frequency of quarterly?
(Select Two)

A. Waterflow devices
B. Radiant energy detectors
C. Smoke detectors
D. Visible notification appliances - answer -A. Waterflow devices
B. Radiant energy detectors
NFPA 72 Table 14.3.1

, A project in an unsprinklered facility is using CI (circuit integrity) cable to
provide a 2-hour fire rated resistance for a circuit. What is the pathway
survivability rating?

A. Level 1
B. Level 2
C. Level 3
D. Level 4 - answer -B. Level 2
NFPA 72 12.4.3

Consider communications methods for supervising station fire alarm systems. A
communication technology which requires annunciation at the supervising station
for degradation of the communications channel not to exceed 90 seconds from the
time of actual failure is _____?

A. Two way radio multiplex systems
B. Performance based technology
C. DACT systems
D. One way private radio systems - answer -A. Two way radio multiplex systems
NFPA 72 Table A.26.6.1

Consider an area where the temperature is 120 degrees Fahrenheit. The most
appropriate type of smoke detector for this environment is _____?

A. Smoke detectors are not appropriate
B. Projected beam
C. Photoelectric
D. Ionization - answer -A. Smoke detectors are not appropriate
NFPA 72 A.17.7.1.8

When testing an FSCS, which of the following modes are required to be tested?
(Select Two)

A. Manual override of normal mode
B. Manual override of automatic mode

Geschreven voor

Instelling
NICET Inspect
Vak
NICET Inspect

Documentinformatie

Geüpload op
30 oktober 2024
Aantal pagina's
5
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$8.29
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
TheExamMaestro Teachme2-tutor
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
144
Lid sinds
2 jaar
Aantal volgers
5
Documenten
3376
Laatst verkocht
6 dagen geleden
Exam Vault

Exam Vault is your trusted destination for high-quality exam materials and study resources. We provide a wide rage of tests and prep guides to help you succeed, whether you're preparing for academic exams, certifications, or professional assessments

3.6

18 beoordelingen

5
9
4
2
3
2
2
0
1
5

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen