Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

ABRET EXAM PREP QUESTIONS AND ANSWERS

Beoordeling
-
Verkocht
-
Pagina's
43
Cijfer
A+
Geüpload op
02-11-2024
Geschreven in
2024/2025

ABRET EXAM PREP QUESTIONS AND ANSWERS

Instelling
ABRET BOARD
Vak
ABRET BOARD

Voorbeeld van de inhoud

ABRET EXAM PREP QUESTIONS AND ANSWERS

Which is important to document to aid in interpretation?
a) low grade fever
b) uncooperative pt
c) pt was awake and alert during recording
d) HV was not performed due to asthma - Answers- c

What additional electrodes could help decipher b/w artifact and cortical activity?
a) respiration transducer
b) sphenoidal
c) EMG
d) EOG - Answers- d

What additional monitoring should be done in a middle age pt who repeatedly alerts
from sleep during EEG?
a) eye movement
b) movement
c) muscle tone
d) respiration - Answers- d

What type of monitoring would be useful in an EEG pt experiencing syncope?
a) movement transducer
b) respiration transducer
c) EOG
d) ECG - Answers- d

BRAIN ABCESS
a) burst suppression
b) ECI
c) focal polymorphic delta activity
d) diffuse slowing - Answers- c

Sphenoidal electrodes are used to record activity from the
a) brain stem
b) anterior temp lobes
c) basal ganglia
d) mesial frontal lobes - Answers- b

A slow wave focus is best seen w/
a) LF 0.3Hz, paper speed 60mm/sec
b) HF 70Hz, paper speed 60mm/sec
c) LF 5Hz, paper speed 15mm/sec
d) LF 0.3Hz, paper speed 15mm/sec - Answers- d

,The best reference electrode in an awake pt w/ excessive temporal myogenic activity
would be
a) ear lobes
b) mastoids
c) neck
d) Cz - Answers- d

14 & 6Hz positive spikes are best recorded w/
a) avg reference
b) contralateral ear reference
c) bipolar chain
d) both ears connected to reference - Answers- b

Which montage would best display the amp of a left temp spike?
a) left temp to ipsi ear
b) left temp to contra ear
c) ant-post bipolar temp chain
d) transverse (coronal) bipolar chain - Answers- b

BEST choice of reference to be used when recording in suspected temp lob epilepsy
a) A1+A2
b) ipsi ear
c) Cz
d) nasopharyngeals - Answers- c

Which settings will help enhance a low volt slow wave that's being masked by muscle
activity?
a) sens 2; LF 5; HF 35
b) sens 10; LF 1; HF 5
c) sens 5; LF 0.3; HF 35
d) sens 7; LF 1; HF 70 - Answers- c

Most appropriate setting change that should be made to enhance cortical slowing?
a) change LFF from 1Hz to 0.1Hz
b) change HFF from 70Hz to 15Hz
c) change LFF from 1Hz to 5Hz
d) change HFF from 70Hz to 25Hz - Answers- a

When using avg reference, if a spike-and-wave focus appears at C3, the abnormality
would be best enhanced by
a) using 35Hz filter and time constant of 0.03sec
b) decreasing sensitivty
c) excluding C3 and surrounding electrodes from reference
d) switching to Cz referential montage - Answers- c

,Which setting could be used to reduce the effects of sweat artifact in a pt w/
asymmetrical low-volt fast activity?
a) S=4mv/mm, LF=1Hz, HF=70Hz
b) S=5mv/mm, LF=5Hz, HF=70Hz
c) S=15mv/mm, LF=5Hz, HF=70Hz
d) S=10mv/mm, LF=0.3Hz, HF=35Hz - Answers- b

Laplacian montage
a) end of chain montage
b) fast fourier transform
c) avg reference
d) source reference derivation - Answers- d

When attempting to minimize relentless muscle artifact, the technologist should be
aware that lowing the HFF could cause artifact to resemble
a) 3Hz spike and wave
b) beta activity
c) polymorphic delta activity
d) vertex waves - Answers- b

Which montage would be best to localize occipital spikes by phase reversal?
a) circumferential bipolar
b) transverse bipolar
c) contralateral ear referential
d) common avg - Answers- a

Waveform of 0.5Hz can best be enhanced w/ a filter of
a) LF 0.3Hz
b) HF 35Hz
c) LF 5Hz
d) LF 1Hz - Answers- a

Referential recording is most appropriate for measuring
a) freq
b) phase
c) duration
d) volt - Answers- d

To enhance the background alpha and beta asymmetry in a recording showing
moderately high volt delta activity, the tech should use
a) shorter time constant and decreased sens
b) longer time constant and increased sens
c) longer time constant and decreased sens
d) shorter time constant and increased sens - Answers- d

Nyquist sampling rate for 100Hz waveforms

, a) 50 samples/sec
b) 25 samples/sec
c) >100 samples/sec
d) >200 samples/sec - Answers- d

Input impedance should be
a) equal to the common mode rejection ratio
b) less than the common mode rejection ratio
c) very low
d) very high - Answers- d

Which of the following is the most appropriate sampling rate used for a HFF setting of
70Hz?
a) 30 per sec
b) 210 per sec
c) 140 per sec
d) 10 per sec - Answers- b

Which of the following extra electrodes might best demonstrate the EEG activity
associated with focal motor twitching of the right corner of the mouth?
a) P5
b) FT9 (T1)
c) C1
d) C5 - Answers- d

An abbreviated 10-20 placement, respiration, ECG, and EOG
a) neonates
b) toddlers
c) ICU pts
d) Elderly pts - Answers- a

Cortical EEG recording can be obscured in pts who are tense and anxious due to
a) multifocal spikes
b) delta slowing
c) generalized spike wave
d) myogenic artifact - Answers- d

Minimal horizontal resolution
a) 16 bits
b) 16 Hz
c) 8 Hz
d) 8 bits - Answers- b

The way a signal is sampled at intervals and assigned a numeric value
a) aliasing
b) sampling rate

Geschreven voor

Instelling
ABRET BOARD
Vak
ABRET BOARD

Documentinformatie

Geüpload op
2 november 2024
Aantal pagina's
43
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$14.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
GEEKA YALA UNIVERSITY
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
2105
Lid sinds
4 jaar
Aantal volgers
1446
Documenten
53870
Laatst verkocht
5 uur geleden

3.8

358 beoordelingen

5
177
4
61
3
48
2
17
1
55

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen