IRC (International Residential Code) - ANSWER: Created to serve as a complete,
comprehensive code regulating the construction of single-family, two-family and
buildings consisting of three or more townhouse units.

First 2 chapters of code book are - ANSWER: Administrative

Plans or supporting documents are almost always required by the controlling
authority prior to issuing a permit. T or F - ANSWER: True

Does the building official have the authority to render interpretations of the code? -
ANSWER: Yes

None of the following require a permit, EXCEPT:
sidewalks and driveways
tiling
an 8 foot fence
playground equipment - ANSWER: 8 foot fence.

Tables and illustrations are always supported by information found in the written
code and footnotes. T or F - ANSWER: False

The amount of evenly distributed weight imposed by inhabitants, goods and
removable objects on a floor or roof system is referred to as - ANSWER: Live load.

If a code requirement is in the book, it is both acceptable and enforceable by the
code official. T or F - ANSWER: True.

Illustrations are typically referred to as - ANSWER: Figures.

Generally speaking, the building official's job is to - ANSWER: Determine that
buildings are built to the minimum enforceable standard.

It is required that all manufacturer instructions be at the jobsite at the time of
inspection. T or F - ANSWER: True.

All of the following are not considered habitable spaces EXCEPT:
bathrooms
kitchens
storage spaces
closets - ANSWER: Kitchen.

,Bathrooms must be provided with an aggregate glazing area no less than _____
square feet, half of which must be openable. - ANSWER: 3.

The maximum height of an egress window above the floor is - ANSWER: 44 inches.

A basement bedroom must have an egress window with a clear opening of at least
______ square feet. - ANSWER: 5.7 sq ft.

At least one side-hinged exit door must be in each dwelling unit, and must be _____
feet wide. - ANSWER: 3.

A porch more than _____ inches above grade must be provided with 36" guards. -
ANSWER: 30 inches.

Wall and ceiling finishes shall have a flame-spread classification of no more than
______ . - ANSWER: 200.

According to code, concrete must reach at least 70% of it's ability within
____________days. - ANSWER: 7 days.

A stud used for a non-bearing partitions may not be notched more than ____% of
the stud width. - ANSWER: 40%.

The Michigan Uniform Energy code applies to new buildings as well as - ANSWER:
Additions, alterations, renovation and repairs.

___________ is a measure of how well the window or door assembly conducts heat.
The lower the number, the better insulation the assembly will provide. - ANSWER: U-
factor.

Energy losses from recessed lighting fixtures can often reach ___% of the total
thermal loss of a ceiling. - ANSWER: 50%.

Michigan requires a minimum thermal resistance of ____________for mechanical
system piping. - ANSWER: R-3.

Oversized HVAC equipment has a higher initial cost, a higher operating cost, provides
less comfort, and shorter life expectancy. T or F - ANSWER: True.

_______ is the compliance route that applies Table 402.1.1 to building envelope
components, and is considered the most simple. - ANSWER: Prescriptive Path.

___________ can be used to satisfy U-factor and SHGC requirements. - ANSWER:
Area weighted averages.

Recessed lights must be _____ rated. - ANSWER: IC (Insulation Contact)

,Up to 15 square feet of glazing per dwelling unit is exempted from U-value
requirements. T or F - ANSWER: True.

The 2009 IECC requires a permanent certificate posted on the electrical distribution
panel. The certificate shall be completed by the builder or - ANSWER: Registered
design professional.

One hurdle contractors face when bidding for an energy efficient project is choosing
materials that fit the design, and also meet - ANSWER: State energy code
requirements.

Historically significant buildings are not exempt from code changes. T or F - ANSWER:
False.

Insulation products (blown and sprayed) must be documented with: - ANSWER: R-
value
Settled thickness
Manufacturer name

The new Michigan codes took effect in - ANSWER: March 2011.

Below grade walls are insulated from the top of the basement wall down to _____
below grade, or the basement floor, whichever is less. - ANSWER: 10.

The _______ is the combined Solar Heat Gain Coefficient of all the glazed
fenestration products in the building. - ANSWER: Area weighted average.

Plans and specifications must be detailed in regards to: - ANSWER: Thermal
insulation R-values
Design criteria
Equipment systems

In Michigan, the residential energy code is based on the _____ IECC, with certain
amendments. - ANSWER: 2009.

___________ is the rate of air infiltration in the presence of a specific pressure
differential. - ANSWER: Air leakage.

Air leakage is the random movement of air into and out of ________ through cracks
and holes. - ANSWER: Windows
Attic access hatches
Recessed lights

R-values for insulation and fenestration requirements by component can be found in
- ANSWER: Table 402.1.1
2009 IECC

, IECC - ANSWER: International Energy Conservation Code

The _____________ compliance method allows for more innovative construction
techniques like SIPs or Advanced Framing. - ANSWER: U-factor and UA alternatives.

R-30 is permitted in vaulted ceilings, but is limited to - ANSWER: 500 sq feet

Floor insulation must be installed to maintain permanent and continuous contact
with the underside of the subfloor decking. T or F - ANSWER: True.

Michigan falls into climate zones - ANSWER: 5, 6 and 7.

It is permissible for supply ducts to be run through the framing cavities of a
residential building. T or F - ANSWER: False.

__________ means an electrical fixture has been tested and listed as suitable for
installation in a cavity where the fixture may come in contact with insulation. -
ANSWER: IC rated (Insulation Contact)

According to the Dept. of Energy, improved energy codes could reduce CO2
emissions by - ANSWER: 3%.

Attic insulation markers must be installed every _____ square feet. - ANSWER: 300
sq ft.

Buildings that are exempted from the new regulations are those with very low
energy use or ones that are neither heated or cooled. T or F - ANSWER: True.

A contractor needs to remove a non-load bearing wall, does he need to pull a
permit? - ANSWER: Yes.

A concrete contractor has been hired by an owner to install a driveway and
sidewalks. The lot is flat and the concrete is being place on undisturbed earth with a
prepared base. Does the contractor need to pull a permit? - ANSWER: No.

A permit has been issued for a building project and there is a code infraction in the
building plans that has been overlooked by the building official. Can the building
official require a correction to a project that they previously overlooked? - ANSWER:
Yes.

Who issues a well and septic permit? - ANSWER: Health department.

Permits are not required for one story detached accessory structures not exceeding:
- ANSWER: 200 sq. feet.
IRC R105

Connected book

Written for

Course

Document information

Uploaded on
November 2, 2024
Number of pages
52
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$18.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
charitywairimuuu Teachme2-tutor
Follow You need to be logged in order to follow users or courses
Sold
18
Member since
1 year
Number of followers
2
Documents
1295
Last sold
7 months ago
EXCELLENT HOMEWORK HELP AND TUTORING ,

EXCELLENT HOMEWORK HELP AND TUTORING ,ALL KIND OF QUIZ AND EXAMS WITH GUARANTEE OF A EXCELLENT HOMEWORK HELP AND TUTORING ,ALL KIND OF QUIZ AND EXAMS WITH GUARANTEE OF A Am an expert on major courses especially; psychology,Nursing, Human resource Management and Mathemtics Assisting students with quality work is my first priority. I ensure scholarly standards in my documents and that\'s why i\'m one of the BEST GOLD RATED TUTORS in STUVIA. I assure a GOOD GRADE if you will use my work.

Read more Read less
4.6

545 reviews

5
409
4
81
3
30
2
18
1
7

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions