Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

ALE Review: Building Laws (Comprehensive review module for building laws, created by JBB for the Philippine ALE June 2019. This module covers the following laws: PD 1096 and its IRR (The National Building Code), BP 344 (Accessibility Law), RA 9514 (Fire C

Beoordeling
-
Verkocht
-
Pagina's
212
Cijfer
A+
Geüpload op
05-11-2024
Geschreven in
2024/2025

ALE Review: Building Laws (Comprehensive review module for building laws, created by JBB for the Philippine ALE June 2019. This module covers the following laws: PD 1096 and its IRR (The National Building Code), BP 344 (Accessibility Law), RA 9514 (Fire C

Meer zien Lees minder
Instelling
....
Vak
....

Voorbeeld van de inhoud

Name: Score:


631 Multiple choice questions

Term 1 of 631
True or false: A building permit is required for repair work done on a structure

True

False

Definition 2 of 631
general allowable travel distance to exits in buildings without a sprinkler system according to RA
9514

1.2 m

1.5 m


46 m

8m

Definition 3 of 631
Who prepares FALAR 1?

contractor


architect


building official

owner

,Definition 4 of 631
RA 9514: minimum number of exits required for 0-499 occupant load

3

900 mm


2


600 mm

Definition 5 of 631
minimum height of curbs at both sides of an accessibility ramp

50 mm


150 mm

100 mm

200 mm

Term 6 of 631
renovation

fire resistance rating of the exterior walls of Type IV construction according to PD 1096

the portion of a means of egress that leads to an exit; generally refers to room doors

any physical change made on a structure to increase its value, utility, and/or improve its
aesthetic quality

physical development consisting mainly of renovation, rehabilitation, retrofit, upgrading,
and the like as well as expansion and/or new construction work within a lot or property that
is under-utilized

,Term 7 of 631
storey

portion of a building/structure included between the uppermost surface (or finish level) of
any floor and the uppermost surface (or finish level) of the next floor above or below it

percentage of the total length of side and rear property lines on which a firewall may be
constructed on R-3 zoned properties with a rear property line of 4 meters or less


construction in a structure involving changes in the materials used, partitioning,
location/size of openings, structural parts, existing utilities and equipment but does not
increase the overall area thereof

True or False: Doors shall not project into a corridor if it will lessen the 1.20 m minimum
unobstructed width required.

Definition 8 of 631
minimum clear width of existing fire escape stairs according to RA 9514

800 mm

1000 mm

400 mm


600 mm

Definition 9 of 631
minimum door width for hospital sleeping rooms and diagnostic treatment rooms (RA 9514)

1.12 m

1.42 m


3.66 m

10 m

, Definition 10 of 631
minimum elevator button size for accessibility

20 mm

30 mm

15 mm


25 mm

Definition 11 of 631
fire resistance rating of Type I construction according to PD 1096

46 m

none


2 hours

4 hours

Definition 12 of 631
minimum lot frontage length for an economic rowhouse (BP 220)

6m


2m

10 m

4m

Geschreven voor

Instelling
....
Vak
....

Documentinformatie

Geüpload op
5 november 2024
Aantal pagina's
212
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$8.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
amzingnurse study smarts
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
1563
Lid sinds
2 jaar
Aantal volgers
63
Documenten
3633
Laatst verkocht
6 uur geleden

4.8

1569 beoordelingen

5
1346
4
184
3
14
2
6
1
19

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen