2024-2025 Actual Exam from Credible Sources
with 100 Questions and Verified Correct Answers
Golden Ticket to Guaranteed A+ Verified by
Professor
__________ Detector has a piping distribution network to the areas being protected. Air
Sampling-Type detector uses a fan inside its housing to draw air. - CORRECT
ANSWER: 3.3.66.1 Air sampling-type
__________ is a feature that can reduce unwanted alarms. - CORRECT ANSWER:
3.3.16 Alarm verification
17.14.8.3* Manual pull stations are required to be red in color. - CORRECT ANSWER:
TRUE
17.5.3.1 The definition of total coverage covers: - CORRECT ANSWER: rooms, halls,
storage areas, basements, attics, lofts, all
A __________ can transmit a signal that indicates on off condition only. - CORRECT
ANSWER: 3.3.132.1 Conventional Initiating Device
A __________ Fire Alarm Box requires that you break a special element so to gain
access to and operate the box. - CORRECT ANSWER: A Breakglass Fire Alarm Box
requires that you break a special element so to gain access to and operate the box.
A Digital Alarm Communicator Receiver cannot accept and display signals sent from the
digital alarm communicator transmitters over the public switched telephone network.
True? - CORRECT ANSWER: FALSE. A Digital Alarm Communicator Receiver can
accept and display signals sent from the digital alarm communicator transmitters over
the public switched telephone network.
, A fire alarm systems secondary power source must not be implemented through using
battery backup. - CORRECT ANSWER: FALSE. A fire alarm systems secondary power
source may be implemented through using battery backup.
A fire plume has a shape which looks like: - CORRECT ANSWER: inverted cone shape
A four-wire smoke detector has how many distinct circuits? - CORRECT ANSWER: two
(2)
A line type detector can perform detection which is: - CORRECT ANSWER: continuous
along a path
A Master Box is publicly accessible. - CORRECT ANSWER: TRUE. It may also be
operated by a remote initiating device.
A Type _____ Public Fire Alarm Reporting System can retransmit alarms to fire stations
manually or automatically. - CORRECT ANSWER: Type A (A for automatic)
An _________
that transmits a signal indicating varying degrees of condition - CORRECT ANSWER:
3.3.132.1 Analog Initiating Device
An AHJ is responsible for: - CORRECT ANSWER: An Authority Having Jurisdiction is
responsible for approving an installation.
An auxiliary box is a fire alarm box that must be operated locally. - CORRECT
ANSWER: FALSE. An Auxiliary Box is a fire alarm box that can be operated from a
remote initiating device only.
An EOL device is always placed at the end of __________ for maintaining supervision. -
CORRECT ANSWER: a class B circuit