Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

ARRT CT Registry Exam (2024/2025) Questions with Correct Detailed Answers || Already Graded A+ RECENT VERSION

Beoordeling
-
Verkocht
-
Pagina's
121
Cijfer
A+
Geüpload op
16-11-2024
Geschreven in
2024/2025

ARRT CT Registry Exam (2024/2025) Questions with Correct Detailed Answers || Already Graded A+ RECENT VERSION What is most likely to have the highest osmolality - ANSWER An ionic IV contrast agent Ionic agents dissociate into - ANSWER ions in solution What types of contrast would be administered for a CT study of the lumbosacral spine? - ANSWER Contrast agents are generally not administered unless there is a suspected mass. To evaluate a mass, iodinated IV contrast is typically administered. If post-pyelogram, intrathecal contrast would have been previously administered. Which studies might cranial nerve XI be visualized? - ANSWER soft tissue neck In order to generate a diagnostic 3D reconstruction of the hips, the reconstruction software utilizes - ANSWER the axial image data What is the appropriate range of coverage for a coronal sinus study? - ANSWER From the dorsum sella to the anterior aspect of the frontal sinus What is a reason for using thinner slices in the posterior fossa compared with the more superior regions of the brain? - ANSWER To reduce beam hardening artifacts to improve spatial resolution A localizer image of what orientations should be used to set up axial slices so that they can be angled parallel to the plane of a specific lumbar disk? - ANSWER Lateral Intravenous contrast is not administered to rule out - ANSWER a herniated disk Axial slices are not generally acquired through the entire thoracic spine, but rather through - ANSWER a few specified disk spaces. It is impossible to position an adult in such a way that one could directly obtain - ANSWER sagittal or coronal images. These are reformatted from the axial images. What is a location where one would expect to find cerebral spinal fluid? - ANSWER Subarachnoid space Fourth ventricle of the brain What is the expected result of a CT number calibration test performed on a water phantom? - ANSWER 0 +/-3 If the system fails the CT number standard deviation test, what is most likely? - ANSWER Detector noise has increased mA is a measurement of? - ANSWER The electron current from cathode to anode What determines slice thickness? - ANSWER Pre-patient collimation If the patient table of a spiral, or helical, scanner is moved at a rate of 0.6cm per gantry rotation, and a pitch of 1.5 is selected what will be the slice thickness? - ANSWER 4mm 6mm/1.5=4mm Slice thickness is equal to? - ANSWER the table incrementation rate divided by the pitch What may be the cause of two parallel black lines seen on a localizer image of a third- or fourth-generation scanner? - ANSWER Two faulty detector elements How would we expect metal to affect the appearance of a localizer image? - ANSWER Any metal within the scan field-of-view may create an artifact. Streaks caused by a combo of beam hardening, the edge gradient effect, the partial volume effect , and motion. Why must we choose a scan field-of-view which is larger than the anatomy to be scanned? - ANSWER to avoid out-of-field artifcacts

Meer zien Lees minder
Instelling
ARRT CT Registry
Vak
ARRT CT Registry

Voorbeeld van de inhoud

ARRT CT Registry Exam
(2024/2025) Questions with Correct
Detailed Answers || Already Graded
A+
<RECENT VERSION>


What is most likely to have the highest osmolality - ANSWER ✔ An ionic IV
contrast agent


Ionic agents dissociate into - ANSWER ✔ ions in solution


What types of contrast would be administered for a CT study of the lumbosacral
spine? - ANSWER ✔ Contrast agents are generally not administered unless there is
a suspected mass.
To evaluate a mass, iodinated IV contrast is typically administered.
If post-pyelogram, intrathecal contrast would have been previously administered.


Which studies might cranial nerve XI be visualized? - ANSWER ✔ soft tissue
neck


In order to generate a diagnostic 3D reconstruction of the hips, the reconstruction
software utilizes - ANSWER ✔ the axial image data

,What is the appropriate range of coverage for a coronal sinus study? - ANSWER
✔ From the dorsum sella to the anterior aspect of the frontal sinus


What is a reason for using thinner slices in the posterior fossa compared with the
more superior regions of the brain? - ANSWER ✔ To reduce beam hardening
artifacts
to improve spatial resolution


A localizer image of what orientations should be used to set up axial slices so that
they can be angled parallel to the plane of a specific lumbar disk? - ANSWER ✔
Lateral


Intravenous contrast is not administered to rule out - ANSWER ✔ a herniated disk


Axial slices are not generally acquired through the entire thoracic spine, but rather
through - ANSWER ✔ a few specified disk spaces.


It is impossible to position an adult in such a way that one could directly obtain -
ANSWER ✔ sagittal or coronal images. These are reformatted from the axial
images.


What is a location where one would expect to find cerebral spinal fluid? -
ANSWER ✔ Subarachnoid space
Fourth ventricle of the brain


What is the expected result of a CT number calibration test performed on a water
phantom? - ANSWER ✔ 0 +/-3

,If the system fails the CT number standard deviation test, what is most likely? -
ANSWER ✔ Detector noise has increased


mA is a measurement of? - ANSWER ✔ The electron current from cathode to
anode


What determines slice thickness? - ANSWER ✔ Pre-patient collimation


If the patient table of a spiral, or helical, scanner is moved at a rate of 0.6cm per
gantry rotation, and a pitch of 1.5 is selected what will be the slice thickness? -
ANSWER ✔ 4mm
6mm/1.5=4mm


Slice thickness is equal to? - ANSWER ✔ the table incrementation rate divided by
the pitch


What may be the cause of two parallel black lines seen on a localizer image of a
third- or fourth-generation scanner? - ANSWER ✔ Two faulty detector elements


How would we expect metal to affect the appearance of a localizer image? -
ANSWER ✔ Any metal within the scan field-of-view may create an artifact.
Streaks caused by a combo of beam hardening, the edge gradient effect, the partial
volume effect , and motion.


Why must we choose a scan field-of-view which is larger than the anatomy to be
scanned? - ANSWER ✔ to avoid out-of-field artifcacts

, One of the most common equipment induced artifacts is the result of - ANSWER
✔ a faulty or miscalibrated detector element.


On a third-generation scanner, if there is a problem with a single detector, it will
be represented as a - ANSWER ✔ ring on the CT images


Ring artifacts are rarely seen on which generation of scanners? - ANSWER ✔
Fourth-generation, and when apparent the cause is usually an error in the back
projection of the reconstruction process


Beam hardening refers to - ANSWER ✔ the increase in the mean energy of the
photons that reach the detectors


What might increase the possibility of motion artifacts occurring? - ANSWER ✔
using no straps or pads so that the patient feels comfortable and unrestricted.


What is the cause of aliasing artifacts - ANSWER ✔ Collecting too few data
samples


what would reduce the partial volume effect? - ANSWER ✔ decreased slice
thickness


What would increase the severity of the edge gradient effect? - ANSWER ✔ a
scanner with a low data sampling rate


what affects the severity of metal artifacts? - ANSWER ✔ the quality,
composition and shape of the metal
the slice thickness

Geschreven voor

Instelling
ARRT CT Registry
Vak
ARRT CT Registry

Documentinformatie

Geüpload op
16 november 2024
Aantal pagina's
121
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$11.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
ProfBenjamin Havard School
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
642
Lid sinds
1 jaar
Aantal volgers
17
Documenten
3855
Laatst verkocht
8 uur geleden
EXCELLENT ACHIEVERS LIBRARY

As a professional tutor, I provide exceptional assistance with homework, quizzes, and exams across various subjects, including Psychology, Nursing, Biological Sciences, Business, Engineering, Human Resource Management, and Mathematics. I am dedicated to offering high-quality support and ensuring that all work meets scholarly standards. To enhance the effectiveness of our services, I work with a team of experienced tutors to create comprehensive and effective revision materials. Together, we are committed to helping students achieve excellent grades through our collaborative efforts and expertise.

Lees meer Lees minder
3.8

135 beoordelingen

5
63
4
18
3
33
2
9
1
12

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen