NC Home Inspector Exam Latest 2024.2025 100%
Accurate With Answers GUARANTEED PASS
An inspector enters a home and notices a strong smell of gas. What should he do? -
ANSWER: Vacate the home and call appropriate people
The expansion device - ANSWER: Changes refrigerant from high temperature high
pressure liquid to low temperature low pressure liquid
The condensing coil - ANSWER: Refrigerant changes from high temperature high
pressure gas to high temperature high pressure liquid
The evaporator coil - ANSWER: Refrigerant changes from a low pressure low
temperature liquid to a low temperature low pressure gas
The compressor - ANSWER: Refrigerant changes from a low pressure low
temperature gas to a high temperature high pressure gas
Automatic safety controls - ANSWER: Devices designed and installed to protect
systems and components from excessively high or low pressures and temperatures,
excessive electrical current, loss of water, loss of ignition, fuel leaks, fire, freezing, or
other unsafe conditions
Central air conditioning - ANSWER: Means a system that uses ducts to distribute
cooled or dehumidifies air to more than one room or uses pipes to distribute chilled
water to heat exchangers in more than one room and that is not plugged into an
electrical convenience outlet
Component - ANSWER: A readily accessible and observable aspect of a system such
as a Floor or wall but not individual pieces such as boards or nails where many
similar pieces make up the component
Cosmetic damage - ANSWER: Superficial blemishes or defects that do not interfere
with the functionality of the component or system
Cross connection - ANSWER: Any physical connection or arrangement between
potable water and any source of contamination
Dangerous or adverse situation - ANSWER: Situations that pose a threat of injury to
the inspector or those situations that require the use of special protective clothing or
safety equipment
Describe - ANSWER: Report in writing a system or component by its type or other
inspected characteristics to distinguish it from other systems or components used
for the same purpose
,Dismantle - ANSWER: To take apart or remove any component device or piece of
equipment that is bolted screwed or fastened by other means and that would not be
dismantled by a homeowner in the course of normal household maintenance
enter - ANSWER: To go into an area to inspect all visible components
Functional drainage - ANSWER: A drain that empties in a reasonable amount of time
and does not overflow when another fixture is drained at the same time
Functional flow - ANSWER: A reasonable flow at the highest fixture in a dwelling
when another fixture is operated simultaneously
Habitable Space - ANSWER: A space in a building for living sleeping eating or cooking.
It does not mean bathroom toilet room closet or any space used for storage
inspect - ANSWER: The act of making a visual inspection
installed - ANSWER: Attached or connected such that an item requires tools for
removal
Normal operating controls - ANSWER: Homeowner operated devices such as a
thermostat wall switch or safety switch
On site water supply quality - ANSWER: Water quality is based on the bacterial
chemical mineral and solids content of the water
operate - ANSWER: To cause systems or equipment to function
readily accessible - ANSWER: A panel provided for homeowner inspection and
maintenance that has removable or operable fasteners or latch devices in order to
be lifted off swung open or otherwise removed by one person and it's edges and
fasteners are not painted in place. This definition is limited to those panels within
normal reach or from a four foot step ladder and that are not blocked by stored
items furniture or building components
readily visible - ANSWER: Seen by using natural or artificial light without the use of
equipment or tools other than a flashlight
Representative number - ANSWER: Means for multiple identical components such as
windows and electrical outlets one such component per room and for multiple
identical exterior components one such component on each side of building
Roof drainage system - ANSWER: Gutters downspouts leaders splash blocks and
similar components used to carry water off a roof and away from a building
shut down - ANSWER: A piece of equipment or a system which cannot be operated
by the device or control that a homeowner should normally use to operate it. If it's
, safety switch or circuit breaker is in the off position or it's fuse is missing or blown
the inspector is not required to reestablish the circuit for the purpose of operating
the equipment or system
Solid fuel heating device - ANSWER: Any wood coal or other similar organic fuel
burning device including fireplaces whether masonry or factory built fireplace inserts
and stoves wood stoves room heaters central furnaces and combinations of these
devices
Structural component - ANSWER: A component that supports non variable forces or
weights dead loads and variable forces or weights live loads
System - ANSWER: A combination of interacting or independent components
assembled to carry out one or more functions
Technically exhaustive - ANSWER: An inspection involving the use of measurements
instruments testing calculations and other means to develop scientific or engineering
findings conclusions or recommendations
Under floor crawl space - ANSWER: The area within the confines of the foundation
and between the ground and the underside of the lowest floor structural component
Home inspections provide - ANSWER: The client with an understanding of the
property conditions as inspected at the time of the home inspection
Home inspectors - ANSWER: Provide a written contract signed by the client before
the inspection is performed. State the home inspection is in accordance with the
standards of practice of the North Carolina home inspector licensure board. Describe
the services performed and the cost. State when an inspection is is for only one or a
limited number of systems or components that the inspection is limited to those
items
DDIR - ANSWER: Describe this systems and components required to be described in
rule .1106, state which systems and components present at the home and
designated for inspection where not inspected and why, state any systems or
components that do not function as intended allowing for normal wear and tear or
appear to not function as intended based on documented tangible evidence.
Describe the system or component state how it is defective explain the implications
of conditions listed in the summary and direct the client to a course of action
Home inspections - ANSWER: Done in accordance with this section are not
technically exhaustive
home inspectors do not report on - ANSWER: Cause or need for repair, methods and
costs of corrections, suitability of property, code compliance or non compliance,
market value of property, advisability or in advisability to purchase property, any
Accurate With Answers GUARANTEED PASS
An inspector enters a home and notices a strong smell of gas. What should he do? -
ANSWER: Vacate the home and call appropriate people
The expansion device - ANSWER: Changes refrigerant from high temperature high
pressure liquid to low temperature low pressure liquid
The condensing coil - ANSWER: Refrigerant changes from high temperature high
pressure gas to high temperature high pressure liquid
The evaporator coil - ANSWER: Refrigerant changes from a low pressure low
temperature liquid to a low temperature low pressure gas
The compressor - ANSWER: Refrigerant changes from a low pressure low
temperature gas to a high temperature high pressure gas
Automatic safety controls - ANSWER: Devices designed and installed to protect
systems and components from excessively high or low pressures and temperatures,
excessive electrical current, loss of water, loss of ignition, fuel leaks, fire, freezing, or
other unsafe conditions
Central air conditioning - ANSWER: Means a system that uses ducts to distribute
cooled or dehumidifies air to more than one room or uses pipes to distribute chilled
water to heat exchangers in more than one room and that is not plugged into an
electrical convenience outlet
Component - ANSWER: A readily accessible and observable aspect of a system such
as a Floor or wall but not individual pieces such as boards or nails where many
similar pieces make up the component
Cosmetic damage - ANSWER: Superficial blemishes or defects that do not interfere
with the functionality of the component or system
Cross connection - ANSWER: Any physical connection or arrangement between
potable water and any source of contamination
Dangerous or adverse situation - ANSWER: Situations that pose a threat of injury to
the inspector or those situations that require the use of special protective clothing or
safety equipment
Describe - ANSWER: Report in writing a system or component by its type or other
inspected characteristics to distinguish it from other systems or components used
for the same purpose
,Dismantle - ANSWER: To take apart or remove any component device or piece of
equipment that is bolted screwed or fastened by other means and that would not be
dismantled by a homeowner in the course of normal household maintenance
enter - ANSWER: To go into an area to inspect all visible components
Functional drainage - ANSWER: A drain that empties in a reasonable amount of time
and does not overflow when another fixture is drained at the same time
Functional flow - ANSWER: A reasonable flow at the highest fixture in a dwelling
when another fixture is operated simultaneously
Habitable Space - ANSWER: A space in a building for living sleeping eating or cooking.
It does not mean bathroom toilet room closet or any space used for storage
inspect - ANSWER: The act of making a visual inspection
installed - ANSWER: Attached or connected such that an item requires tools for
removal
Normal operating controls - ANSWER: Homeowner operated devices such as a
thermostat wall switch or safety switch
On site water supply quality - ANSWER: Water quality is based on the bacterial
chemical mineral and solids content of the water
operate - ANSWER: To cause systems or equipment to function
readily accessible - ANSWER: A panel provided for homeowner inspection and
maintenance that has removable or operable fasteners or latch devices in order to
be lifted off swung open or otherwise removed by one person and it's edges and
fasteners are not painted in place. This definition is limited to those panels within
normal reach or from a four foot step ladder and that are not blocked by stored
items furniture or building components
readily visible - ANSWER: Seen by using natural or artificial light without the use of
equipment or tools other than a flashlight
Representative number - ANSWER: Means for multiple identical components such as
windows and electrical outlets one such component per room and for multiple
identical exterior components one such component on each side of building
Roof drainage system - ANSWER: Gutters downspouts leaders splash blocks and
similar components used to carry water off a roof and away from a building
shut down - ANSWER: A piece of equipment or a system which cannot be operated
by the device or control that a homeowner should normally use to operate it. If it's
, safety switch or circuit breaker is in the off position or it's fuse is missing or blown
the inspector is not required to reestablish the circuit for the purpose of operating
the equipment or system
Solid fuel heating device - ANSWER: Any wood coal or other similar organic fuel
burning device including fireplaces whether masonry or factory built fireplace inserts
and stoves wood stoves room heaters central furnaces and combinations of these
devices
Structural component - ANSWER: A component that supports non variable forces or
weights dead loads and variable forces or weights live loads
System - ANSWER: A combination of interacting or independent components
assembled to carry out one or more functions
Technically exhaustive - ANSWER: An inspection involving the use of measurements
instruments testing calculations and other means to develop scientific or engineering
findings conclusions or recommendations
Under floor crawl space - ANSWER: The area within the confines of the foundation
and between the ground and the underside of the lowest floor structural component
Home inspections provide - ANSWER: The client with an understanding of the
property conditions as inspected at the time of the home inspection
Home inspectors - ANSWER: Provide a written contract signed by the client before
the inspection is performed. State the home inspection is in accordance with the
standards of practice of the North Carolina home inspector licensure board. Describe
the services performed and the cost. State when an inspection is is for only one or a
limited number of systems or components that the inspection is limited to those
items
DDIR - ANSWER: Describe this systems and components required to be described in
rule .1106, state which systems and components present at the home and
designated for inspection where not inspected and why, state any systems or
components that do not function as intended allowing for normal wear and tear or
appear to not function as intended based on documented tangible evidence.
Describe the system or component state how it is defective explain the implications
of conditions listed in the summary and direct the client to a course of action
Home inspections - ANSWER: Done in accordance with this section are not
technically exhaustive
home inspectors do not report on - ANSWER: Cause or need for repair, methods and
costs of corrections, suitability of property, code compliance or non compliance,
market value of property, advisability or in advisability to purchase property, any