In general, mold modifications are as follows: - ANSWER: Venting affects lows,
damping the midrange and horn effects boost highs.
Basic verification involves: - ANSWER: checking MCL and UCL in quiet and noise.
Sound field is - ANSWER: a controlled environment
The configuration and height of the tympanogram can be a factor in deciding the
proper matrix for the fitting of a hearing aid: - ANSWER: A high Type A tells us to
decrease the output by 2-3 dB
You cannot use feedback checks when - ANSWER: checking the telephone coil
Verification procedures: - ANSWER: Check the accuracy of your fitting.
The problems produced by excessive ambient noise are - ANSWER: greater for the
lower frequencies than the higher frequencies
The decibel is - ANSWER: a ratio between two intensities
REUR measurement are taken in - ANSWER: an open human ear canal
When a hearing aid is dead, you can check the receiver and microphone function by:
- ANSWER: turning on the instrument telecoil
The dividing line between the external and middle ear is the - ANSWER: tympanic
membrane
The cochlea, acting as a frequency analyzer, distributes acoustic stimuli to places
along the basilar membrane according to frequency. This forms the basis of a
hypothesis called the: - ANSWER: Place Theory
An organic disorder is when there is damage to: - ANSWER: The hearing mechanism,
the neural pathways and the brain.
The speed of sound in air, in feet per second, is : - ANSWER: 1100
,Properly selected hearing instruments should allow: - ANSWER: The patient to wear
an instrument at a comfortable loudness level, improved communication and have
better hearing aided.
Crystal microphones and receivers: - ANSWER: are very fragile
Which of the following is not a coupler used for measuring hearing aid performance?
- ANSWER: Zwisks Ear Simulator
Small diameter tubing of SIA hearing aids has the effect of : - ANSWER: reducing the
high frequency gain
The function of a microphone is to : - ANSWER: convert acoustic energy into
electrical energy
Vent an earmold : - ANSWER: is the most common modification made on an earmold
When a new hearing instrument has feedback at the patients comfortable level, the
problem is usually: - ANSWER: too much wax in the ear canal
With SIE-S hearing aids: - ANSWER: The only signal is from the hearing aid and
phrase effects from a vent are not an issue.
The most comfortable level is: - ANSWER: About 45 dB HL or 65 dB SPL for normal
ears
Any complex sound can be broken down into individual frequencies by a technique
known as: - ANSWER: Fourier Spectral analysis
The adult ear canal: - ANSWER: rises upward and forward, then descends to the
drum.
An effective verification is: - ANSWER: a measure able improvement in
communication
Which of the following is not included in correct test protocols? - ANSWER: plugging
the hearing aid vent to control feedback
Most conducive losses: - ANSWER: Are medically correctable, display a breakdown or
obstruction in middle ear and display good discrimination
The T position on a hearing aid switch can be used to - ANSWER: amplify a telephone
conversation, couple hearing aid into a loop inductor, couple directly into the audio
of a radio or tv
The following components can change or modify the frequency response of a
hearing instrument: - ANSWER: a microphone
, Afferent fibers: - ANSWER: transmit from the cochlea to the brain.
User satisfaction must include: - ANSWER: patient preferences
The following measurements use SPL as a reference: - ANSWER: Probe microphones,
sound field aided thresholds, and ANSI specifications
Speech discrimination tests: - ANSWER: approximate a sample of speech sounds in
an ordinary conversation.
A formant is: - ANSWER: a frequency region within a complex tone where certain
harmonics have relatively large energy.
Malingering is a category of : - ANSWER: non organic loss
Bone conduction threshold worse than air conduction thresholds may be caused by :
- ANSWER: poor placement of vibrator, skull fracture, thickness of skull
Part of the basic law of electrical energy is : - ANSWER: protons attract electrons
Some patients with binaural amplification can experience: - ANSWER: degredation
effect
The scala tympani is filled with: - ANSWER: perilymph
The following is a transducer: - ANSWER: electret microphone
A sensorineural hearing loss is due to a disorder in the: - ANSWER: Inner ear
In pure tone testing, threshold means : - ANSWER: the lowest intensity the client
hears 50% of the time.
The ear, due to its physical characteristics, enhances which frequencies? - ANSWER:
2,000 - 5,000hz
When performing aided sound field testing, what degree of angle (from the
patient/client) is the speaker to be placed? - ANSWER: 45
Rather than asking a patient/client, "How does that sound?," which test can a
hearing healthcare professional use to measure the change in a patient's/client's
hearing? - ANSWER: APHAB
A hearing healthcare professional completes a fitting of new open-fit technology for
a patient/client.
Which outcome measurement tool should the hearing healthcare professional use to
determine proper fit? - ANSWER: Real ear measurement