Which of the following can be avoided by proper use of a automatic injector
pressure limit control?
1. Vessel damage
2. catheter whipping
2. catheter breakage
A. 1 and 2 only
B. 1 and 3 only
C. 2 and 3 only
D. 1,2, and 3
What is angiography?
A. radiographic exam of veins
B. radiographic exam of arteries
C. radiographic exam of vessels
D. the study of vascular flow patterns
Answer : C
What term describes a guide wire in which position of the inside portion can be
varied?
A. J guide wire
B. straight guide wire
C. fixed core
D. moveable core
D
How is the measurement of the flow rate of an automatic contrast injector
determined?
A. contrast amount delivered per time
B. Heating device
C. contrast volume times contrast rate
D. syringe size
A
Which of the following is used during cardiac catheterization?
1. Guide wire
2. Catheter
3. Pressure injector
A. 1 and 2 only
B. 1 and 3 only
C. 2 and 3 only
D. 1, 2 and 3
D
What is a normal adult Blood Pressure
,A. 100/40
B. 120/40
C. 120/80
D. 160/80
C
What is pitressin?
A. Vasopressin
B. Corticosteroid
C. Diazepam
D. Atropine
A
What is the best projection for left ventriculography?
A. 30 degrees RAO
B. 60 degrees RAO
C. 20 degrees LAO
D. 45 degrees LAO
A
Which of the following describes the response of a catheter to twisting and
turning?
A. torque
B. memory
C. friction
D. control
A
Which French size catheter has an outer diameter of 2.31 mm?
A. four
B. five
C. six
D. seven
D
A 2.31 mm outer diameter catheter equals 7 French scale. Each 0.33 mm equals
approximately 1 French
How long is the injection time for 12ml of contrast media delivered at 2.5 ml/sec?
A. 0.2 sec
B. 2.5 sec
C. 4.8 sec
D. 30 sec
C
What does the acronym "PSI" represent?
A. probable significant instances
B. Partly saturated intravenously
, C. pounds per square inch
D. pounds per inch
PSI stands for: pounds per square inch
Which of the following can be avoided by proper use of a automatic injector
pressure limit control?
1. Vessel damage
2. catheter whipping
2. catheter breakage
A. 1 and 2 only
B. 1 and 3 only
C. 2 and 3 only
D. 1,2, and 3
Proper use of an automatic injector pressure control avoids vessel damage, catheter
whipping, and catheter damage.
Which of the following are the functions of a digital image processor?
1. digitizing television frames
2. displaying digital images
3. storing digital images
A. 1 and 2 only
B. 1 and 3 only
C. 2 and 3 only
D. 1, 2, and 3
A digital processor digitizes television frames and stores, displays, and manipulates
them.
What effect does the addition of side holes in a catheter have on the total flow
rate?
A. 10 to 20 percent increase
B. 50 to 60 percent increase
C. 10 to 20 percent decrease
D. 50 to 60 percent decrease
The addition of side holes in a catheter will increase the flow rate to 10 to 20 percent.
What is the area relationship indicated by the power factor of an automated
injector?
1. power cylinder
2. catheter
3. syringe
A. 1 and 2 only
B. 1 and 3 only
C. 2 and 3 only
D. 1, 2, and 3
The power factor of an automatic power injector indicates the area relationship of the
power cylinder to the syringe
How long is the injection time for 12ml of contrast media delivered at 2.5 ml/sec?
A. 0.2 sec
B. 2.5 sec