Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

EPA 608 Type 3 Exam With complete solutions

Beoordeling
-
Verkocht
-
Pagina's
11
Cijfer
A+
Geüpload op
18-11-2024
Geschreven in
2024/2025

EPA 608 Type 3 Exam With complete solutions

Instelling
Vak

Voorbeeld van de inhoud

EPA 608 Type 3 Exam With complete
solutions

On low pressure chillers, moisture typically enters the refrigerant system through -
correct Answers-air leaks from areas with gaskets or fittings

The maximum test pressure for leak testing a low pressure centrifugal is: - correct
Answers-10 psig

Leak test and repair the chiller to reduce refrigerant loss from a pruge unit on CFC-11
chiller - correct Answers-...

A hydrostatic tube test kit is used to: - correct Answers-determine if a tube leaks

Commercial and industrial process refrigeration systems must be repaired when the
leak rate exceeds ____ of the charge per year. - correct Answers-35%

Refrigerant recovery typically start with liquid recovery it is faster. - correct Answers-...

A rupture disc on a recovery vessel for a low pressure refrigerants relieves at: - correct
Answers-15 psig

According to ASHRAE Guideline 3-1996, if the pressure in a system rises from 1 mm
Hg to a level above ____ during a standing vacuum test, the system should be checked
for leaks. - correct Answers-2.5 mm Hg

The primary water source for a recovery unit condensing coil is _____. - correct
Answers-local municipal water supply

When recharging a refrigeration system with R-11, what vaporpressure is necessary in
the shells before changing with liquid? - correct Answers-16.9" Hg vacuum

After recovering the liquid refrigerant you must: - correct Answers-recover the vapor
refrigerant

According to the EPA there is approximately _____ refrigerant vapor left in an average
350 ton R-11 chiller at 0 psig pressure once all the R-11 liquid has been removed. -
correct Answers-100 pounds

Charging refrigerant liquid into a refrigeration system when it is under a 29 inch Hg
vacuum can cause the: - correct Answers-system water to freeze

, A system does not have to be evacuated all the way to the required level when: -
correct Answers-leaks in the appliance make evacuation to the prescribed level
unattainable

Which of the foloowing repairs would ALWAYS be considered "major" under EPA's -
correct Answers-replacement of evaporator coil

Under EPA's regulation's _______ is used to pressurize a low pressure chiller for the
purpose of opening the system for a non major repair? - correct Answers-warming the
refrigerant

If you are using a recovery machine manufactored AFTER 11-15-93 you must evacuate
an low pressure appliance to _______ before making a major repair. - correct Answers-
25 mm of Hg absolute

After reaching the required recovery vacuum on a chiller, you should - correct Answers-
Wait for at least a few minutes to see if the system pressure rises, indicating that there
is till refrigerant in a liquid form or in the oil

The pressure corresponding to 32 F for R-123 - correct Answers-20 inches of HG
vacuum

When evacuating a system the use of too large a vacuum pump can cause? - correct
Answers-trapped water to freeze

Refrigerant-11 at a pressure of 17 inches HG vacuum has a saturation temperature of: -
correct Answers-35F

During the evacuation of a system containing large amounts of moisture you can
prevent freezing of this moisture by increasing the pressure with______gas - correct
Answers-nitrogen

ASHRAE standard 15-1994 requires that each machinery room must activate an alarm
and mechanical ventilation beofre refrigerant concentrations exceed: - correct Answers-
the threshold limit valve and time weighted average

The typical design burst pressure for a rupture disk on a low pressure centrifugal air-
conditioning system is set at_______ - correct Answers-15 psi

Heat pumps that have been retrofitted from R22 to R407C should be leak checked with:
- correct Answers-pressurized nitrogen

When a new system has been assembled, the first thing to do is: - correct Answers-
pressurize the system with inert gas and leak check

Geschreven voor

Vak

Documentinformatie

Geüpload op
18 november 2024
Aantal pagina's
11
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$11.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
EXAMHAVEN

Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
EXAMHAVEN Havard School
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
4
Lid sinds
1 jaar
Aantal volgers
2
Documenten
1595
Laatst verkocht
4 maanden geleden

0.0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen