Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

ANALYTICAL CHEMISTRY FINAL- ACS EXAM QUESTIONS AND ANSWERS A+ GRADED. BUY Quality Materials!

Beoordeling
-
Verkocht
-
Pagina's
6
Cijfer
A+
Geüpload op
19-11-2024
Geschreven in
2024/2025

ANALYTICAL CHEMISTRY FINAL- ACS EXAM QUESTIONS AND ANSWERS A+ GRADED. BUY Quality Materials! Using the same thermometer, a lab group measures the room temperature three times over the course of their experiment and they got 23.1, 22.7, and 23.3. What type of error is this: systematic, random, both, or a mistake? random error because fluctuation is + and - You plot a calibration curve using the concentration values listed in your lab procedure, instead of using the actual concentrations of your diluted standards recalculated using the dilution equation. What type of error is this: systematic, random, both, or a mistake? mistake During a colorimetric titration, you repeatedly read your final volume of titrant at the point where it turns very dark blue color, instead of at the first time there is a persistent faint blue color. What type of error is this: systematic, random, both, or a mistake? systematic error to be corrected, or a mistake if you can't collect meaningful data. you transfer 5.00 mL of sample into the same volumetric flask on three separate occasions, and record the mass. You clean out the flask with DI water and shake it, but you do not dry the flask, after each measurement. The mass measurements for the three trials were 47.385 g, 47.295, and 48.293 g. What type of error is this: systematic, random, both, or a mistake? systematic, because you can account for it and fix it. Do method blanks, blind samples, calibration curves, spiked recoveries, and automatic sample injection go with accuracy or precision? accuracy. they help us get results that are closer to the true value. Do replicated samples, and relative standard deviation go with accuracy or precision? Precision. They help to give us measurements that are closer together numerically. True or false?The true value of a measurement is never known exactly. I mean, true True or false? The use of a student's TTEST at 95% confidence level tests one's method for precision. false. TTEST is for accuracy. True or false? The mean, x, approaches the true mean, u, for small sample sizes. false. b/c the law of large numbers True or false? The Grubbs test (G-TEST) is used to determine if a questionable value can be rejected as an outlier. true As an analytical chemist working for Coca-Cola, your supervisor has tasked you with determining the concentration of caffeine in various samples of soda. As part of your method, you need to prepare 500 (plus or minus 5) mL of 0.035 M (+_ 0/003) M caffeine (MW = 194.19 g/mol) stock solution.

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

ANALYTICAL CHEMISTRY FINAL- ACS EXAM QUESTIONS
AND ANSWERS A+ GRADED. BUY Quality Materials!

Using the same thermometer, a lab group measures the room temperature three
times over the course of their experiment and they got 23.1, 22.7, and 23.3. What
type of error is this: systematic, random, both, or a mistake?
random error because fluctuation is + and -
You plot a calibration curve using the concentration values listed in your lab
procedure, instead of using the actual concentrations of your diluted standards
recalculated using the dilution equation. What type of error is this: systematic,
random, both, or a mistake?
mistake
During a colorimetric titration, you repeatedly read your final volume of titrant at
the point where it turns very dark blue color, instead of at the first time there is a
persistent faint blue color. What type of error is this: systematic, random, both, or
a mistake?
systematic error to be corrected, or a mistake if you can't collect meaningful data.
you transfer 5.00 mL of sample into the same volumetric flask on three separate
occasions, and record the mass. You clean out the flask with DI water and shake
it, but you do not dry the flask, after each measurement. The mass measurements
for the three trials were 47.385 g, 47.295, and 48.293 g. What type of error is this:
systematic, random, both, or a mistake?
systematic, because you can account for it and fix it.
Do method blanks, blind samples, calibration curves, spiked recoveries, and
automatic sample injection go with accuracy or precision?
accuracy. they help us get results that are closer to the true value.
Do replicated samples, and relative standard deviation go with accuracy or
precision?
Precision. They help to give us measurements that are closer together numerically.
True or false?The true value of a measurement is never known exactly.
I mean, true
True or false? The use of a student's TTEST at 95% confidence level tests one's
method for precision.
false. TTEST is for accuracy.
True or false? The mean, x, approaches the true mean, u, for small sample sizes.
false. b/c the law of large numbers
True or false? The Grubbs test (G-TEST) is used to determine if a questionable
value can be rejected as an outlier.
true
As an analytical chemist working for Coca-Cola, your supervisor has tasked you
with determining the concentration of caffeine in various samples of soda. As
part of your method, you need to prepare 500 (plus or minus 5) mL of 0.035 M (+_
0/003) M caffeine (MW = 194.19 g/mol) stock solution.

, a. calculate the mass (in grams) of caffeine that you should weigh out to make
your stock solution.

b. what is the concentration fo your stock solution in units of ppm? you can
assume the density is the same as water (1.0 g/mL)
c. Calculate both the absolute and percent relative uncertainty associated with
your mass calculation in part A, via propagation of error.
a. 0.035 mol x (194.19 g/1 mol) = 6.796 g caffeine

b. ppm is mass solute/ mass sample * 10^6. or mg/L

6.796 g x (1000 mg/1 g)=6796.65 mg/0.500L is 13593.3 ppm.

c.
relative uncertainty:
mass % = 0.003/0.0035 x 100 = 8.57145
volume 5/500 x 100 = 1%

total relative uncertainty
% rel un= sqrt (8.57`4)^2 + (1.0)^2
= total relative un = 8.629


absolute uncertainty = 8.629 /100 x 6.796
0.5864 abs un

mass +- abs un = 6.8 (+-0.6)
mass +_ rel un = 6.8 (+_9%)
Iron is typically found as an oxide in ore samples. You analyze 1.1324 g sample of
iron ore containing Fe3O4. All of the sample is dissolved in concentrated HCl.
The resulting solution is diluted with water, producing the iron (III) ion in solution.
The Fe 3+ ion is precipitated as Fe2O3 x H2O by addition of NH3. After filtration
and washing, the residue is ignited at a high temperature to drive off the water
and to give 0.5394 g of pure Fe2O3 (MW= 159.69 g/mol).

a. balance the reaction below.
_____Fe3O4 + ____O2 > _______Fe2O3
b. Calculate the mass % of Fe3O4 (MW= 231.54 g/mol). in the original ore sample.

c. your supervisor only wants ore samples with a mass % of iron greater or equal
to 45.0%. Does your sample meet this requirement?
a. 4Fe3O4 + 1O2 > 6Fe2O3
b. 0.5394 g Fe2O3 x (1 mol Fe2O3/159.69 g) x (4 mol Fe3O4/6 mol Fe2O3) x (231.54
g/ 1 mol Fe3O4) = 0.512 g Fe3O4

Geschreven voor

Vak

Documentinformatie

Geüpload op
19 november 2024
Aantal pagina's
6
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$9.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
TopGradeSolutions Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
95
Lid sinds
2 jaar
Aantal volgers
9
Documenten
13297
Laatst verkocht
8 uur geleden
TOPGRADESOLUTIONS

Here we offer revised study materials to elevate your educational outcomes. We have verified learning materials (Research, Exams Questions and answers, Assignments, notes etc) for different courses guaranteed to boost your academic results. We are dedicated to offering you the best services and you are encouraged to inquire further assistance from our end if need be. Having a wide knowledge in Nursing, trust us to take care of your Academic materials and your remaining duty will just be to Excel. Remember to give us a review, it is key for us to understand our clients satisfaction. We highly appreciate clients who always come back for more of the study content we offer, you are extremely valued. All the best.

Lees meer Lees minder
4.9

171 beoordelingen

5
159
4
7
3
4
2
0
1
1

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen