Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

NICET Level 1,Level 2 & Level 3 Fire Alarms (Latest 2024/ 2025 Updates STUDY BUNDLE PACKAGE WITH SOLUTIONS) Qs & As| 100% Correct| Grade A (Verified Answers)

Beoordeling
-
Verkocht
-
Pagina's
16
Cijfer
A+
Geüpload op
24-11-2024
Geschreven in
2024/2025

NICET Level 1,Level 2 & Level 3 Fire Alarms (Latest 2024/ 2025 Updates STUDY BUNDLE PACKAGE WITH SOLUTIONS) Qs & As| 100% Correct| Grade A (Verified Answers)

Instelling
Vak

Voorbeeld van de inhoud

NICET Level 1,Level 2 & Level 3 Fire Alarms (Latest
2024/ 2025 Updates STUDY BUNDLE PACKAGE WITH
SOLUTIONS) Qs & As| 100% Correct| Grade A (Verified
Answers)

The operable part of a manually actuated alarm initiating device shall not be less
than ____ inches AFF? - ANSWER42

Consider the use of grounding electrodes. Rod and pipe electrodes shall not be less
than____ feet in length? - ANSWER8

Smoke detectors should not be located in a direct airflow or closer than ____ inches
from an air supply diffuser or return air opening? - ANSWER36

Consider the use of visible notification appliances. Wall mounted appliances shall be
mounted such that the entire lens is not less than ____ inches above the finished
floor? - ANSWER80

How many 16 gauge conductors are permitted in a 4 x 1 1/2 inches square box? -
ANSWER12

Wall mounted audible appliances shall have their tops above the finished floors at
heights of not less than ____ inches and below the finished ceilings at distances of
not less than 6 inches? - ANSWER90

An ____ db ambient sound level with a 6-hour exposure time requires hearing
protection. - ANSWER92dbA

Spot type heat sensing fire detectors shall be located on the ceiling not less than
____ inches from the sidewall. - ANSWER4

While operating an aerial lift, which of the following is not required? Select three) -
ANSWERStabilizer hook, Grounding pole, Insulation mat

Spot type smoke detectors shall be located on the ceiling or, if on a sidewall,
between the ceiling and ____ inches down from the ceiling to the top of the
detector. - ANSWER12

The distance between spot type heat detectors shall not exceed their listed spacing,
and shall be detectors within a distance of ________ the listed spacing, measured at
right angles from all the walls? - ANSWEROne half

Where partitions extend to within ____ percent of the ceiling height, the spaces
separated by the partitions shall be considered as separate rooms? - ANSWER15

,Consider 1,000 feet total of 18 gauge soild coated copper at 167o Fahrenheit. The
resistance of this conductor is ____ ohm? - ANSWER8.08

Consider the installation of heat detectors on a ceiling with beams. A ceiling shall be
treated as a smooth ceiling if the beams project no more than ___ inches below the
ceiling? - ANSWER4

Which of the following conductor types is an acceptable substitute for FPLR? -
ANSWERFPLP and CMP

The distance between smoke detectors shall not exceed a nominal spacing of ____
feet? - ANSWER30

A portable ladder shall support at least ____ times the maximum intended load. -
ANSWER4

Consider smoke detector placement on a peaked ceiling. Detectors shall be spaced
and located within ____ feet of the peak, measured horizontally? - ANSWER3

Ladders must be inspected____ to identify any visible defects that could cause
employee injury? - ANSWERBefore each initial use on each shift

Consider heat detectors with listed spacing of 50 feet placed on a smooth and flat
ceiling which is 10 feet AFF. Based on this ceiling height, the heat detectors shall
have a spacing of ____ feet between devices? - ANSWER50

Consider the use of PLFA fire alarm cable. The size of conductors in multiconductor
cable shall not be smaller than____ AWG? - ANSWER26

You are using a power tool that has a 3-prong (grounded) plug. The only outlets
available are 2-prong (non-grounded). What can be done? - ANSWERLocate a 3-
prong outlet or use a tool within a 2-prong plug.

The power source for a power limited fire alarm circuit shall be a listed PLFA or Class
____ transformer? - ANSWER3

Which of the following is a symptom of heat stroke? (Select three) - ANSWERRed
Skin, Elevated body temperature, and Rapid, weak pulse

The maximum number of 14 AWG, RHH conductors permitted in 1/2 inch EMT is
____? - ANSWER4

If a door release detector is specifically listed for door frame mounting, or if a listed
combination or integral detector door closer assembly is used, ____ detectors shall
be required if installed according to the manufacturers published instructions? -
ANSWER1

, Intermediate Metal Conduit shall be securely fastened within ___ feet of each outlet
box, junction box, device box, cabinet, conduit body, or other conduit termination? -
ANSWER3

Consider a waterflow detection device. Activation of the initiating device shall occur
within ____ seconds of waterflow at the initiating device when flow occurs which is
equal to or greater than that from a single sprinkler with the smallest orifice size
installed in the system? - ANSWER90

Rigid metal conduit shall be supported on straight runs at intervals of not more than
____ feet? - ANSWER10

The branch circuit supplying the fire alarm equipment(s) shall be permitted to supply
____? - ANSWERNo other loads

Which of the following is an acceptable method for performing a smoke entry test of
a spot type smoke detector? - ANSWERListed and labeled smoke product acceptable
to the manufacturer.

What are the general care instructions for injuries to muscles, bones and joints? -
ANSWERRest, Immobilize and Apply Cold

Which of the following tests are required for system type smoke detectors in one-
and two- family dwellings? - ANSWERFunctional test per manufacturer's instructions

A person has sustained a burn from a portable heater. Which of the following should
not be done when treating the burn? - ANSWERApply Ice

What is the periodic inspection frequency of sealed lead acid batteries? -
ANSWERSemiannually

When installing fire alarm cable in a hoist way, the cable shall be installed using
____. - ANSWEREMT, IMC, RMC

Fixed-temperature, Non restorable spot type heat detectors must be replaced ____
years from initial installation, or have 2 detectors per 100 laboratory tested? -
ANSWER15

Prior to installing fire alarm system cabling, it is noted that the area above a drop
ceiling does not have return air ducts. The whole space is used as an environmental
air return. What type of fire alarm cabling is best suited for this application? -
ANSWERFPLP

When performing a charger test for sealed lead acid batteries, the volatge should be
____ volts per cell +/- 0.02 volts? - ANSWER2.3

Gekoppeld boek

Geschreven voor

Vak

Documentinformatie

Geüpload op
24 november 2024
Aantal pagina's
16
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$18.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
knoowy0010 Teachme2-tutor
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
5
Lid sinds
1 jaar
Aantal volgers
0
Documenten
1039
Laatst verkocht
1 week geleden

4.7

141 beoordelingen

5
112
4
14
3
12
2
3
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen