Tech A says that evacuating the A/C system will remove air and moisture from the system. Tech B says
that evacuating an A/C system will remove dirt particles from the system. Who is right? - ANSWER:Tech A
Only

There is a growling or rumbling noise at the A/C compressor when the system is off and the engine is
running. The noise stops when the s is turned on. Tech A says that a bad compressor bearing could be
the cause. Tech B says that a bad compressor clutch bearing could be the cause. Who is right? -
ANSWER:Tech B Only

The reading shown above are taken with the A/C system operating at an ambient (outside) temperature
of 85F (29C). What do the readings indicate? - ANSWER:Low refrigerant level

Recovery/recycling equipment must have shutoff valves located within 12-in, (30cm) of the hoses'
service ends so that? - ANSWER:Refrigerant discharge can be kept to a minimum

When recovering refrigerant from an A/C system, how long should the tech wait after the
recovery/recycling unit has been turned off to see it there is any residual pressure in the system? -
ANSWER:5 Minutes

A system with a low pressure on the low side and heavy frost accumulation on the inlet side of the side
Thermostatic Expansion Valve (TXV) indicates a? - ANSWER:Clogged screen or TXV stuck closed

A blower motor only works on high speed. Which of the following causes is the MOST LIKELY? -
ANSWER:Defective blower resistor

A customer complains that when accelerating his car with the A/C on, the cold air flow from the dash
outlets shifts on the floor. Tech A says that this is caused by a faulty check in the vacuum reservoir. Tech B
says that this condition is due to a vacuum leak. Who is right? - ANSWER:Both A and B

When pressure testing the cooling system on a late-model gasoline engine vehicle, the pressure on the
tester drops but no leaks can be found in the engine compartment. Tech A starts the engine and, seeing
the pressure on the tester gauge increase says that there is an internal leak, a blown head gasket. Tech B
says that there cannot be an internal leak because the engine oil looks normal, not milky like it would be
if coolant were present, and there is no white smoke coming from the exhaust pipe. Who is right? -
ANSWER:Tech A Only

When identifying an A/C system, Tech A says that the accumulator located between the evaporator and
compressor is an indication that the system has an orifice tube. Tech B says that when the high-side
service port fitting is smaller than the one on the low side, the system uses R134a refrigerant. Who is
right? - ANSWER:Tech A Only

When troubleshooting an ATC system, the system responds when the ambient and in-vehicle
temperature sensors are heated and cooled. However, there is no response when the sun load sensor is
exposed to a light source. Tech A says that the problem is with the systems programmer. Tech B says that
the problem is with the sun load sensor. Who is right? - ANSWER:Tech B Only

, The following are all methods of orifice tube replacement EXCEPT? - ANSWER:Disconnect the liquid line
from the evaporator inlet line and, using a twisting motion to break free of the line, pull out the orifice
tube with an extractor tool

Tech A says when there is a "U" DTC, it should be repaired before any further diagnostics can be
performed. Tech B says "U" DTCs indicate there is nothing wrong with the A/C system? - ANSWER:Tech A
Only

A vehicle with R134a refrigerant in the A/C system has a refrigerant leak. Tech A says that a propane gas
leak tester should be used to find the location of the leak. Tech B says that an electronic leak detector
should be used to check for leaks. Who is right? - ANSWER:Tech B

Which of the following is a true statement regarding R134a refrigerant? - ANSWER:It requires a different
desiccant than R12

The compressor in an A/C system does not run. When a jumper wire is used to connect the battery-
positive terminal to the power connector, the compressor clutch engages. Tech A says that the clutch coil
is defective. Tech B says that the pressure cycling switch could be defective. Who is right? - ANSWER:Tech
B

The floor inside a vehicle is wet and there is a slimy film on the windows. Tech A says that the heater
core is leaking. Tech B says that the evaporator caser drain plug is clogged. Who is right? - ANSWER:Tech
A

During A/C system operation, a knocking sound can be heard coming from the compressor. Tech A says
that there could be internal compressor damage. Tech B says that the compressor mounting brackets
and bushings should be checked. Who is right? - ANSWER:Both A and B

All of the following could causer poor heater performance EXCEPT: - ANSWER:stuck open heater control
valve

During an A/C system performance test, the air temperature at the center outlet duct is warm to slightly
cool and the low and high-side pressures on the manifold gauge set are both low. All of the following
could be the cause of these symptoms EXCEPT: - ANSWER:Plugged condenser

What is the minimum system pressure necessary to leak test with an electronic leak detector? -
ANSWER:50 psi

Observing the data stream while operating a HVAC system on a ate model vehicle the counts for the
blend door change when the vehicle is moved outside the mid day sun. Tech A says there is an
intermittent problem with the blend door actuator that will eventually set a DTC. Tech B says that under
no circumstances should the counts change on the blend door motor. Who is right? - ANSWER:Neither A
or B

When diagnosing an ATC system, most of the system temperature sensors can be tested for? -
ANSWER:Resistance and voltage drop

During an A/C system performance test, high-side pressure was found to be excessive and the A/C
compressor continued to run. Tech A says that the high-pressure cutout switch could be defective. Tech B
says that there could be air flow obstruction at the condenser. Who is right? - ANSWER:Both A and B

Gekoppeld boek

Geschreven voor

Vak

Documentinformatie

Geüpload op
29 november 2024
Aantal pagina's
6
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$18.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF


Ook beschikbaar in voordeelbundel

Beoordelingen van geverifieerde kopers

Alle reviews worden weergegeven
1 jaar geleden

5.0

1 beoordelingen

5
1
4
0
3
0
2
0
1
0
Betrouwbare reviews op Stuvia

Alle beoordelingen zijn geschreven door echte Stuvia-gebruikers na geverifieerde aankopen.

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
TEACHME3 Teachme2-tutor
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
7
Lid sinds
1 jaar
Aantal volgers
0
Documenten
499
Laatst verkocht
10 maanden geleden
TEACH ME 2

Welcome to TestBanksGuru, your go-to source for high-quality test banks and study materials designed to help you excel academically. We offer a comprehensive range of resources including test banks, study guides, solution manuals, and other study materials, all meticulously curated to ensure accuracy and effectiveness. Our affordable, instantly accessible materials are complemented by excellent customer support, making your learning experience seamless and efficient. Trust Testbanksguru to be your partner in academic success, providing the tools you need to achieve your educational goals.

Lees meer Lees minder
4.2

419 beoordelingen

5
210
4
126
3
56
2
19
1
8

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen